OBJECTIVE: To identify the factors that are associated with rod slippage and to study the pattern of achieved length gain with a standard distraction methodology.
SUMMARY OF BACKGROUND DATA: Ability to achieve successful magnetically controlled growing rod (MCGR) distraction is crucial for gradual spine lengthening. Rod slippage has been described as a failure of internal magnet rotation leading to a slippage and an inability to distract the rod. However, its onset, significance, and risk factors are currently unknown. In addition, how this phenomenon pertains to actual distracted lengths is also unknown.
METHODS: A total of 22 patients with MCGR and at least six distraction episodes were prospectively studied. Patients with rod slippage occurring less than six distraction episodes were considered early rod slippage whereas those with more than six episodes or have yet to slip were grouped as late rod slippage. The association of parameters including body habitus, maturity status, age of implantation, total number of distractions, months of distraction from initial implantation, initial and postoperative Cobb angle, T1-T12, T1-S1, T5-T12 kyphosis, curve flexibility, instrumented length, and distance between magnets in dual rods and between the magnets and apex of the curve with early or late onset of rod slippage were studied. Differences between expected and achieved distraction lengths were assessed with reference to rod slippage episodes and rod exchanges to determine any patterns of diminishing returns.
RESULTS: Patients had mean age of 7.1 years at diagnosis with mean follow-up of 49.8 months. A mean 32.4 distractions were performed per patient. Early rod slippage occurred in 14 patients and late rod slippage occurred in eight patients. Increased height, weight, body mass index, older age, increased T1-12 and T1-S1 lengths, and less distance between magnets were significantly associated with early rod slippage. Expected distraction lengths did not translate to achieve distraction lengths and reduced gains were only observed after achieving one-third of the allowable distracted length in the MCGR. Length gains return to baseline after rod exchange.
CONCLUSION: This is the first study to specifically analyze the impact of rod slippage on distraction lengths and the risk factors associated with its onset and frequency. Increased body habitus and reduced distance between internal magnets significantly influenced rod slippage events. Diminishing returns in distracted length gains were only observed after a period of usage.
LEVEL OF EVIDENCE: 3.
OBJECTIVE: The aim of this study was to investigate the impact of COVID-19 pandemic on the clinical practices of spine surgeons within the Asia Pacific region.
SUMMARY OF BACKGROUND DATA: COVID-19 pandemic had changed spine surgeons' clinical practices and their concerns toward personal and family risk of infection.
METHODS: This cross-sectional survey was carried out from May 4, 2020 to June 4, 2020. The questionnaire was administered using REDCAP. The online questionnaire includes four sections. First section includes surgeon's demographics, background, type of clinical practice, and status of pandemic in their country. Second section includes volume and the type of spine surgery practice before the COVID pandemic. Third section includes changes of clinical practice during the pandemic and the last section was regarding their concern on COVID transmission.
RESULTS: Total of 222 respondents from 19 countries completed the questionnaire. During the pandemic, 92.3% of the respondents felt their clinical practice was affected. 58.5% respondents reported reduced outpatient clinic hours and 74.6% respondents reported reduced operation theatre hours due to the enforcement by the hospital administration. The mean reduction of clinic volume for all countries was 48.1%. There was a significant reduction in the number of surgeries performed in Japan, Malaysia, India, Philippines, and South Korea. This was due to reduced patient load. More than 60% of respondents were worried being infected by COVID-19 virus and >68% were worried of transmission to their family members.
CONCLUSION: COVID-19 pandemic has significantly affected the clinical and surgical practice of spine surgeons in the Asia Pacific region. Clinics were closed or the practice hours reduced. Similarly, surgical theaters were closed, reduced, or limited to semi-emergency and emergency surgeries. Spine surgeons were moderately concerned of contracting COVID-19 during their clinical practice but were extremely concerned to transmit this disease to their family members.
LEVEL OF EVIDENCE: 4.
METHODS: A cross-sectional survey was carried out among spine surgeons in Asia Pacific. The questionnaires were focused on the usage, recycling and disposal of PPE.
RESULTS: Two hundred and twenty-two surgeons from 19 countries participated in the survey. When we sub-analysed the differences between countries, the provision of adequate PPE by hospitals ranged from 37.5% to 100%. The usage of PPE was generally high. The most used PPE were surgical face masks (88.7%), followed by surgical caps (88.3%), gowns (85.6%), sterile gloves (83.3%) and face shields (82.0%). The least used PPE were powered air-purifying respirators (PAPR) (23.0%) and shoes/boots (45.0%). The commonly used PPE for surgeries involving COVID-19 positive patients were N95 masks (74.8%), sterile gloves (73.0%), gowns (72.1%), surgical caps (71.6%), face shields (64.4%), goggles (64.0%), shoe covers (58.6%), plastic aprons (45.9%), shoes/boots (45.9%), surgical face masks (36.5%) and PAPRs (21.2%). Most PPE were not recycled. Biohazard bins were the preferred method of disposal for all types of PPE items compared to general waste.
CONCLUSIONS: The usage of PPE was generally high among most countries especially for surgeries involving COVID-19 positive patients except for Myanmar and Nepal. Overall, the most used PPE were surgical face masks. For surgeries involving COVID-19 positive patients, the most used PPE were N95 masks. Most PPE were not recycled. Biohazard bins were the preferred method of disposal for all types of PPE.
PURPOSE: To study the various surgical practices of different surgeons in the Asia-Pacific region.
OVERVIEW OF LITERATURE: Given the diversity among Asia-Pacific surgeons, there is no clear consensus on the preferred management strategies for cervical myelopathy. In particular, the role of prophylactic decompression for silent cervical spinal stenosis is under constant debate and should be addressed.
METHODS: Surgeons from the Asia-Pacific Spine Society participated in an online questionnaire comprising 50 questions. Data on clinical diagnosis, investigations and outcome measures, approach to asymptomatic and silent cervical spinal stenosis, guidelines for surgical approach, and postoperative immobilization were recorded. All parameters were analyzed by the Mantel-Haenszel test.
RESULTS: A total of 79 surgeons from 16 countries participated. Most surgeons used gait disturbance (60.5%) and dyskinetic hand movement (46.1%) for diagnosis. Up to 5.2% of surgeons would operate on asymptomatic spinal stenosis, and 18.2% would operate on silent spinal stenosis. Among those who would not operate, most (57.1%) advised patients on avoidance behavior and up to 9.5% prescribed neck collars. For ossification of the posterior longitudinal ligament (OPLL), anterior removal was most commonly performed for one-level disease (p<0.001), whereas laminoplasty was most commonly performed for two- to four-level disease (p=0.036). More surgeons considered laminectomy and fusion for multilevel OPLL. Most surgeons generally preferred to use a rigid neck collar for 6 weeks postoperatively (p<0.001).
CONCLUSIONS: The pooled recommendations include prophylactic or early decompression surgery for patients with silent cervical spinal stenosis, particularly OPLL. Anterior decompression is primarily suggested for one- or two-level disease, whereas laminoplasty is preferred for multilevel disease.
METHODS: An online REDCap questionnaire was circulated to surgeons in the Asia-Pacific region during the period of July 2019 to September 2019 to inquire about various components of nonoperative treatment for AIS. Aspects under study included access to screening, when MRIs were obtained, quality-of-life assessments used, role of scoliosis-specific exercises, bracing criteria, type of brace used, maturity parameters used, brace wear regimen, follow-up criteria, and how braces were weaned. Comparisons were made between middle-high income and low-income countries, and experience with nonoperative treatment.
RESULTS: A total of 103 responses were collected. About half (52.4%) of the responders had scoliosis screening programs and were particularly situated in middle-high income countries. Up to 34% obtained MRIs for all cases, while most would obtain MRIs for neurological problems. The brace criteria were highly variable and was usually based on menarche status (74.7%), age (59%), and Risser staging (92.8%). Up to 52.4% of surgeons elected to brace patients with large curves before offering surgery. Only 28% of responders utilized CAD-CAM techniques for brace fabrication and most (76.8%) still utilized negative molds. There were no standardized criteria for brace weaning.
CONCLUSION: There are highly variable practices related to nonoperative treatment for AIS and may be related to availability of resources in certain countries. Relative consensus was achieved for when MRI should be obtained and an acceptable brace compliance should be more than 16 hours a day.
PURPOSE: To evaluate the inter-rater reliability of Rajasekaran's kyphosis classification through a multicenter validation study.
OVERVIEW OF LITERATURE: The classification of kyphosis, developed by Rajasekaran, incorporates factors related to curve characteristics, including column deficiency, disc mobility, curve magnitude, and osteotomy requirements. Although the classification offers significant benefits in determining prognosis and management decisions, it has not been subjected to multicenter validation.
METHODS: A total of 30 sets of images, including plain radiographs, computed tomography scans, and magnetic resonance imaging scans, were randomly selected from our hospital patient database. All patients had undergone deformity correction surgery for kyphosis. Twelve spine surgeons from the Asia-Pacific region (six different countries) independently evaluated and classified the deformity types and proposed their surgical recommendations. This information was then compared with standard deformity classification and surgical recommendations.
RESULTS: The kappa coefficients for the classification were as follows: 0.88 for type 1A, 0.78 for type 1B, 0.50 for type 2B, 0.40 for type 3A, 0.63 for type 3B, and 0.86 for type 3C deformities. The overall kappa coefficient for the classification was 0.68. Regarding the repeatability of osteotomy recommendations, kappa values were the highest for Ponte's (Schwab type 2) osteotomy (kappa 0.8). Kappa values for other osteotomy recommendations were 0.52 for pedicle subtraction/disc-bone osteotomy (Schwab type 3/4), 0.42 for vertebral column resection (VCR, type 5), and 0.30 for multilevel VCRs (type 6).
CONCLUSIONS: Excellent accuracy was found for types 1A, 1B, and 3C deformities (ends of spectrum). There was more variation among surgeons in differentiating between one-column (types 2A and 2B) and two-column (types 3A and 3B) deficiencies, as surgeons often failed to recognize the radiological signs of posterior column failure. This failure to identify column deficiencies can potentially alter kyphosis management. There was excellent consensus among surgeons in the recommendation of type 2 osteotomy; however, some variation was observed in their choice for other osteotomies.