Displaying all 4 publications

Abstract:
Sort:
  1. Chai HY, Swee TT, Seng GH, Wee LK
    Biomed Eng Online, 2013;12:27.
    PMID: 23565999 DOI: 10.1186/1475-925X-12-27
    The high variations of background luminance, low contrast and excessively enhanced contrast of hand bone radiograph often impede the bone age assessment rating system in evaluating the degree of epiphyseal plates and ossification centers development. The Global Histogram equalization (GHE) has been the most frequently adopted image contrast enhancement technique but the performance is not satisfying. A brightness and detail preserving histogram equalization method with good contrast enhancement effect has been a goal of much recent research in histogram equalization. Nevertheless, producing a well-balanced histogram equalized radiograph in terms of its brightness preservation, detail preservation and contrast enhancement is deemed to be a daunting task.
  2. Chai HY, Wee LK, Swee TT, Salleh ShH, Chea LY
    Biomed Eng Online, 2011;10:87.
    PMID: 21952080 DOI: 10.1186/1475-925X-10-87
    Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the latter process of epiphysis extraction.
  3. Wee LK, Chai HY, Samsury SR, Mujamil NF, Supriyanto E
    An Acad Bras Cienc, 2012 Dec;84(4):1157-68.
    PMID: 23207710
    Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
  4. Ng CA, Wong LY, Chai HY, Bashir MJK, Ho CD, Nisar H, et al.
    Water Sci Technol, 2017 Sep;76(5-6):1389-1398.
    PMID: 28953465 DOI: 10.2166/wst.2017.326
    Three different sizes of powdered activated carbon (PAC) were added in hybrid anaerobic membrane bioreactors (AnMBRs) and their performance was compared with a conventional AnMBR without PAC in treating palm oil mill effluent. Their working volume was 1 L each. From the result, AnMBRs with PAC performed better than the AnMBR without PAC. It was also found that adding a relatively smaller size of PAC (approximately 100 μm) enhanced the chemical oxygen demand removal efficiency to 78.53 ± 0.66%, while the concentration of mixed liquor suspended solid and mixed liquor volatile suspended solid were 8,050 and 6,850 mg/L, respectively. The smaller size of PAC could also enhance the biofloc formation and biogas production. In addition, the smaller particle sizes of PAC incorporated into polyethersulfone membrane resulted in higher performance of membrane fouling control and produced better quality of effluent as compared to the membrane without the addition of PAC.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links