OBJECTIVE: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries.
METHODS: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction
METHODS: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled. Countries were stratified by the WHO regional classification. Patients were or were not implanted with an ICD at their discretion. The outcomes were all-cause mortality and SCD.
RESULTS: We enrolled 4222 patients, and 3889 patients were included in the analysis. The mean follow-up period was 21.6 ± 10.2 months. There were 433 (11.1%) instances of all-cause mortality and 117 (3.0%) cases of SCD. All-cause mortality was highest in primary prevention (PP) patients from Southeast Asia and secondary prevention (SP) patients from the Middle East and Africa. The SCD rates among PP and SP patients were both highest in South Asia. Multivariate Cox regression modelling demonstrated that in addition to the independent predictors identified in previous studies, both geographic region and ICD use were associated with all-cause mortality in patients with high SCD risk. Primary prophylactic ICD implantation was associated with a 36% (HR = 0.64, 95% CI 0.531-0.802, p
OBJECTIVES: The objectives of this study was to determine whether patients with primary prevention (PP) indications with specific risk factors (1.5PP: syncope, nonsustained ventricular tachycardia, premature ventricular contractions >10/h, and low ventricular ejection fraction <25%) are at a similar risk of life-threatening arrhythmias as patients with secondary prevention (SP) indications and to evaluate all-cause mortality rates in 1.5PP patients with and without devices.
METHODS: A total of 3889 patients were included in the analysis to evaluate ventricular tachycardia or fibrillation therapy and mortality rates. Patients were stratified as SP (n = 1193) and patients with PP indications. The PP cohort was divided into 1.5PP patients (n = 1913) and those without any 1.5PP criteria (n = 783). The decision to undergo ICD implantation was left to the patient and/or physician. The Cox proportional hazards model was used to compute hazard ratios.
RESULTS: Patients had predominantly nonischemic cardiomyopathy. The rate of ventricular tachycardia or fibrillation in 1.5PP patients was not equivalent (within 30%) to that in patients with SP indications (hazard ratio 0.47; 95% confidence interval 0.38-0.57) but was higher than that in PP patients without any 1.5PP criteria (hazard ratio 0.67; 95% confidence interval 0.46-0.97) (P = .03). There was a 49% relative risk reduction in all-cause mortality in ICD implanted 1.5PP patients. In addition, the number needed to treat to save 1 life over 3 years was 10.0 in the 1.5PP cohort vs 40.0 in PP patients without any 1.5PP criteria.
CONCLUSION: These data corroborate the mortality benefit of ICD therapy and support extension to a selected PP population from underrepresented geographies.
PURPOSE: The objective of this analysis was to examine the mortality benefit in PP patients by guideline-indicated device type: ICD and CRT-D.
METHODS: Improve sudden cardiac arrest was a prospective, nonrandomized, nonblinded multicenter trial that enrolled patients from regions where ICD utilization is low. PP patient's CRT-D or ICD eligibility was based upon the 2008 ACC/AHA/HRS and 2006 ESC guidelines. Mortality was assessed according to guideline-indicated device type comparing implanted and nonimplanted patients. Cox proportional hazards methods were used, adjusting for known factors affecting mortality risk.
RESULTS: Among 2618 PP patients followed for a mean of 20.8 ± 10.8 months, 1073 were indicated for a CRT-D, and 1545 were indicated for an ICD. PP CRT-D-indicated patients who received CRT-D therapy had a 58% risk reduction in mortality compared with those without implant (adjusted hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61, p