PURPOSE: In this systematic review, data on dental implants' survival in sinus augmentation sites with platelet-rich plasma were examined.
MATERIALS AND METHODS: Randomized controlled trials on the topic with a minimum mean follow-up of 6 months with no language restriction were considered. Other study designs on the topic were excluded. Accordingly, relevant articles were searched in Clinicaltrials.gov, Cochrane databases, PubMed/Medline, and Scopus up to April 2021. Using the Cochrane risk of bias assessment tool, the listed studies' risk of bias was evaluated. From the included studies, the pertinent information was taken and pooled for qualitative and quantitative analysis using R software 4.1.1.
RESULTS: Six randomized controlled trials involving 188 patients who underwent sinus augmentation with and without platelet-rich plasma, and 781 implants were included for qualitative and quantitative analysis. Four hundred and eleven implants were placed in the intervention group (with platelet-rich plasma) and 370 implants were placed in the control group (without platelet-rich plasma). The pooled estimate (OR 0.84, 95% CI 0.37 to 1.91; I2 = 0%) indicated that there was no statistically significant difference observed between the groups. The test for subgroup differences showed no statistically significant differences between the subgroups (p = 0.45) with no heterogeneity (I2 = 0%).
CONCLUSION: The bias associated with selective reporting of outcome data was considered as some concern for bias. This systematic review revealed that the effect of platelet-rich plasma is uncertain on the survival of dental implants.
OBJECTIVES: The aim of the study was to evaluate the deviation of implant placement performed with a surgical guide fabricated by means of the rapid prototyping technique (the PolyJet™ technology).
MATERIAL AND METHODS: Twenty sheep mandibles were used in the study. Pre-surgical cone-beam computed tomography (CBCT) scans were acquired for the mandibles by using the Kodak 9000 3D cone-beam system. Two implants with dimensions of 4 mm in diameter and 10 mm in length were virtually planned on the 3D models of each mandible by using the Mimics software, v. 16.0. Twenty surgical guides were designed and printed using the PolyJet technology. A total of 40 implants were placed using the surgical guides, 1 on each side of the mandible (2 implants per mandible). The post-surgical CBCT scans of the mandibles were performed and superimposed on the pre-surgical CBCT scans. The amount of deviation between the virtually planned placement and the actual implant placement was measured, and a descriptive analysis was done.
RESULTS: The results showed that the mean deviation at the implant coronal position was 1.82 ±0.74 mm, the mean deviation at the implant apex was 1.54 ±0.88 mm, the mean depth deviation was 0.44 ±0.32 mm, and the mean angular deviation was 3.01 ±1.98°.
CONCLUSIONS: The deviation of dental implant placement performed with a 3D-printed surgical guide (the PolyJet technology) is within the acceptable 2-millimeter limit reported in the literature.