Displaying all 2 publications

Abstract:
Sort:
  1. Bradley, D.A., Ramli, A.T., Hashim, S., Wagiran, H., Webb, M., Jeynes, C.
    ASM Science Journal, 2010;4(1):15-21.
    MyJurnal
    This research was focused on the thermoluminescence (TL) response of commercially produced single-mode telecommunication optical fibre manufactured by INOCORP (Canada). The fibres were either in the form of pure silica (SiO2) or as SiO2 doped with Ge or Al at concentrations appropriate for total internal reflection, as required for telecommunication purposes. Each of these INOCORP fibres had a core diameter of 125 ± 0.1 μm. It was noted that dopant concentration was not included among the data provided in the accompanying product data sheet. A particularly important parameter for obtaining the highest TL yield in this study was the dopant concentration of the SiO2 fibre. The dopants tended to diffuse during the production of the optical fibre. To obtain this parameter, proton induced X-ray emission (PIXE) analysis was utilised. PIXE while having limited depth resolution could unambiguously identify elements and analyse trace elements with a detection limit approaching μg g–1. For Al-doped fibres, dopant concentrations in the range of 0.98 – 2.93 mol% had been estimated, the equivalent range for Ge-doped fibres was 0.53 – 0.71 mol%. A linear dose response was observed following 2.5 MeV proton irradiation for Ge- and Al-doped fibres for up to 7 min exposure.
  2. Fadzil, M.S.A., Mohd Noor, N., Tamchek, N., Ung, N.M., Alawiah, A., Abdullah, N., et al.
    MyJurnal
    The thermoluminescence kinetic parameters of Ge-doped flat fibre have been investigated comprehensively using the computerized glow curve deconvolution analysis. The Ge-doped flat fibre was irradiated to 6 MV and 10 MV photon beam with dose ranging from 100 cGy to 300 cGy. Analysis was done using WinGCF software on the dependence of the glow curve intensity on dose delivered and the determination of the trap parameters. Ge-doped flat fibre was found to be linear over the entire dose range explored for both 6 MV and 10 MV irradiations with r2 value of 0.9955 and 0.9933 respectively. The glow curve consists of five individual glow peaks. The peak height increases with increasing irradiation dose. The first peak (P1) is a dominant individual peak for low temperature peak (LTP) with the maximum temperature ranging from 167.4°C to 179.0°C for both beams studied. Meanwhile, peak (P4) is a dominant individual glow curve for high temperature peak (HTP) with maximum temperature for 6 MV and 10 MV and is observed between 264.5°C to 279.4°C. Peak 1 has the lowest activation energy which is less than 0.72 eV while peak 2 shows the highest activation energy (1.3 eV < Ea < 2.1 eV) which indicates the deepest electrons trap. The results showed that the peak integral will increases as the dose increases. The Ge-doped flat fibre demonstrated the second-order kinetic peak behavior by exhibiting the symmetric shape of the glow curve with high temperature half of the curve slightly broader than the low temperature half, which suggests the possibility of electron retrapping.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links