Displaying all 7 publications

Abstract:
Sort:
  1. Saidatul A, Azlan C, Megat Amin M, Abdullah B, Ng Kh
    Biomed Imaging Interv J, 2010 Jan-Mar;6(1):e1.
    PMID: 21611060 MyJurnal DOI: 10.2349/biij.6.1.e2
    Computed tomography (CT) fluoroscopy is able to give real time images to a physician undertaking minimally invasive procedures such as biopsies, percutaneous drainage, and radio frequency ablation (RFA). Both operators executing the procedure and patients too, are thus at risk of radiation exposure during a CT fluoroscopy.This study focuses on the radiation exposure present during a series of radio frequency ablation (RFA) procedures, and used Gafchromic film (Type XR-QA; International Specialty Products, USA) and thermoluminescent dosimeters (TLD-100H; Bicron, USA) to measure the radiation received by patients undergoing treatment, and also operators subject to scatter radiation.The voltage was held constant at 120 kVp and the current 70mA, with 5mm thickness. The duration of irradiation was between 150-638 seconds.Ultimately, from a sample of 30 liver that have undergone RFA, the study revealed that the operator received the highest dose at the hands, which was followed by the eyes and thyroid, while secondary staff dosage was moderately uniform across all parts of the body that were measured.
  2. Azlan CA, Ng KH, Anandan S, Nizam MS
    Australas Phys Eng Sci Med, 2006 Sep;29(3):278-80.
    PMID: 17058591
    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
  3. Mahre MB, Wahid H, Rosnina Y, Jesse FF, Azlan CA, Khumran AM, et al.
    Anim. Reprod. Sci., 2014 Aug;148(3-4):245-50.
    PMID: 25015846 DOI: 10.1016/j.anireprosci.2014.06.006
    This study provides standard information on the attributes of sperm and describes the surface structure of normal and abnormal spermatozoa of Rusa timorensis. Two fertile stags were used as the source of semen collected during the first breeding season commencing from April 5 to July 2, 2012. Another five stags were used as the source of semen collected during the second breeding season commencing from April 1 to June 27, 2013. Semen samples were collected from the stags using an electro-ejaculator. The ejaculate was processed and samples prepared for light and scanning electron microscopy (SEM) according to standard methods. No significant difference (P>0.05) was found between sperm attributes in comparison between different stags and different months of the fertile seasons. The results of this study have also demonstrated that there are no differences in size, shape and surface structure between spermatozoa of the different stags and different months of the fertile seasons. Sperm attributes (volume, pH, sperm concentration, general motility, progressive motility and viability) were 2.2±0.29 ml, 7.2±0.17, 886.3±39.7×10(6) spermatozoa/ml, 78.7±2.01%, 80.8±1.85% and 83.2±0.85%, respectively. Morphological analysis showed low percentage of abnormal spermatozoa 13.9±2.88%. Scanning electron microscopy revealed spermatozoa which consisted of a flat paddle-shaped head, short neck and a tail, which was subdivided into midpiece, principal piece and endpiece. The average spermatozoon was 66.2±0.69 μm in total length. The flat paddle-shaped head was 7.8±0.28 μm long, 4.2±0.15 μm at its widest width, 2.4±0.18 μm basal width and 0.7±0.0 2μm thick. As for the tail, the midpiece length was 13.2±0.14 μm, 0.6±0.04 μm in diameter; the principal piece was 42.6±0.04μm, and 2.8±0.06 μm for the endpiece. Abnormal spermatozoa such as tapered head, microcephalic head, decapitated spermatozoa and bent tails were observed. Results provide standard information useful for development of strategies for semen cryopreservation and assisted reproductive technology in this species.
  4. Mahre MB, Wahid H, Rosnina Y, Jesse FF, Azlan CA, Yap KC
    Anim. Reprod. Sci., 2013 Oct;141(3-4):148-53.
    PMID: 24012278 DOI: 10.1016/j.anireprosci.2013.07.012
    A study was conducted to profile the plasma progesterone (P4) concentrations and establish the length of oestrous cycle in the Rusa timorensis during the breeding season. Five healthy hinds were selected for peripheral blood sampling twice weekly to gauge the P4 levels by radioimmunoassay, at the start of the breeding season indicated by rutting behaviours of sexually active males. The hinds were polyestrous as proven by the cyclic trend of P4 levels. After the presumptive oestrus indicated by the lowest P4 concentrations (0.20±0.09ng/ml), this ovarian hormone was markedly elevated on day 7 of the cycle (0.78±0.20ng/ml), reached its peak (2.61±0.23ng/ml, P<0.05) on day 14, and then declined to the basal level in the subsequent oestrus. The mean oestrous cycle length in R. timorensis during the breeding season was 19.2 days with a range of 18-21 days, and the pattern of circulating progesterone during the oestrous cycle of the R. timorensis is similar to those of other deer species. It was also observed that the length of oestrous cycle of R. timorensis determined by gauging the progesterone levels and observation of the oestrous behaviours as well as changes in the cellular pattern of vaginal epithelial cells are highly consistent.
  5. Azlan CA, Mohd Nasir NF, Saifizul AA, Faizul MS, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2007 Dec;30(4):288-91.
    PMID: 18274069
    Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.
  6. Suppiah S, Rahmat K, Mohd-Shah MN, Azlan CA, Tan LK, Aziz YF, et al.
    Clin Radiol, 2013 Sep;68(9):e502-10.
    PMID: 23706826 DOI: 10.1016/j.crad.2013.04.002
    To investigate the diagnostic accuracy of single-voxel proton magnetic resonance spectroscopy (SV (1)H MRS) by quantifying total choline-containing compounds (tCho) in differentiating malignant from benign lesions, and subsequently, to analyse the relationship of tCho levels in malignant breast lesions with their histopathological subtypes.