MATERIALS AND METHODS: From March 2015 to August 2016, all men consecutively undergoing transrectal ultrasound (TRUS)-guided prostate biopsy with total PSA values ≤ 20ng/ ml were recruited. Blood samples were taken immediately before undergoing prostate biopsy. The performance of total PSA, %fPSA, %p2PSA and PHI in determining the presence of PCa on prostate biopsy were compared.
RESULTS: PCa was diagnosed in 25 of 84 patients (29.7%). %p2PSA and PHI values were significantly higher (p<0.05) in patients with PCa than those without PCa. The areas under the receiver operating characteristic curves for total PSA, %fPSA, %p2PSA and PHI were 0.558, 0.560, 0.734 and 0.746, respectively. At 90% sensitivity, the specificity of PHI (42.4%) was five times better than total PSA (8.5%) and two times better than %fPSA (20.3%). By utilising PHI cut-off >22.52, 27 of 84 (32.1%) patients could have avoided undergoing biopsy.
CONCLUSION: Findings of our study support the potential clinical effectiveness of PHI in predicting PCa in a wider concentration range of total PSA up to 20ng/ml.