Displaying all 8 publications

Abstract:
Sort:
  1. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
  2. Hashim NA, Abd Razak NA, Gholizadeh H, Abu Osman NA
    JMIR Serious Games, 2021 Feb 04;9(1):e17017.
    PMID: 33538698 DOI: 10.2196/17017
    BACKGROUND: Brain plasticity is an important factor in prosthesis usage. This plasticity helps with brain adaptation to learn new movement and coordination patterns needed to control a prosthetic hand. It can be achieved through repetitive muscle training that is usually very exhausting and often results in considerable reduction in patient motivation. Previous studies have shown that a playful concept in rehabilitation can increase patient engagement and perseverance.

    OBJECTIVE: This study investigated whether the inclusion of video games in the upper limb amputee rehabilitation protocol could have a beneficial impact for muscle preparation, coordination, and patient motivation among individuals who have undergone transradial upper limb amputation.

    METHODS: Ten participants, including five amputee participants and five able-bodied participants, were enrolled in 10 1-hour sessions within a 4-week rehabilitation program. In order to investigate the effects of the rehabilitation protocol used in this study, virtual reality box and block tests and electromyography (EMG) assessments were performed. Maximum voluntary contraction was measured before, immediately after, and 2 days after interacting with four different EMG-controlled video games. Participant motivation was assessed with the Intrinsic Motivation Inventory (IMI) questionnaire and user evaluation survey.

    RESULTS: Survey analysis showed that muscle strength and coordination increased at the end of training for all the participants. The results of Pearson correlation analysis indicated that there was a significant positive association between the training period and the box and block test score (r8=0.95, P

  3. Kuan PX, Tan PW, Jobli AT, Abd Razak N
    Med J Malaysia, 2016 Aug;71(4):206-208.
    PMID: 27770122 MyJurnal
    Differences in systolic blood pressure reading between arms are common but could signal trouble if the discrepancy is significant. Early detection of aortic dissection could invariably determine patient's survivability. Hence, a high index of suspicion with prompt diagnostic imaging is vital for accurate diagnosis.
  4. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
  5. Mehmood W, Abd Razak NA, Lau MS, Chung TY, Gholizadeh H, Abu Osman NA
    Proc Inst Mech Eng H, 2019 Feb;233(2):181-192.
    PMID: 30518308 DOI: 10.1177/0954411918816124
    Transtibial prosthetic sockets can be fabricated either by the conventional way, which involve using plaster of Paris bandages for casting. This will include modifications through hand, scanning and digital imaging of software. The aim of this study is to determine the circumferential profiles and conduct a volumetric analysis of a conventional socket that has fabrication using biosculptor technology. In doing this, a male transtibial amputee, age 28 years old with stable health condition was studied, where circumferential measurements were taken at intervals of 1 cm from the distal end of the residual limb to the medial tibial plateau level. Furthermore, the interior volume of both sockets and residuum were determined directly using water displacement method. A comparative value for the calculation of volume was also carried out using engineering mathematical equations. From these measurements, a total surface bearing transtibial sockets was fabricated to compare the changes of circumferential values of both sockets. The finding shows a percentage of the difference between the volume of the residual limb and conventional sockets to be 6.09%, whereas the biosculptor fabrication socket was 7.84% using the water displacement method. A comparison of circumferential profiles and volumetric analysis findings on the contrary showed that socket fabricated using the biosculptor technology is interchangeable with the conventional socket with more advantages, where biosculptor technology produces cheaper sockets and faster process with digital function in the procedure, unlike the conventional manual technique.
  6. Arsad N, Abd Razak N, Omar MH, Shafiee MN, Kalok A, Cheah FC, et al.
    PMID: 35564596 DOI: 10.3390/ijerph19095201
    This exploratory study aimed to evaluate the effects of antenatal corticosteroids in singleton pregnancies of Asian women prior to elective cesarean section (CS) at early term on neonatal respiratory outcomes.

    METHODS: This is a pilot and pragmatic randomized trial conducted at a university hospital in Malaysia. Women with singleton pregnancies planned for elective CS between 37+0 and 38+6 weeks gestation were randomly allocated into the intervention group, where they received two doses of IM dexamethasone 12 mg of 12 h apart, 24 h prior to surgery OR into the standard care, control group, and both groups received the normal routine antenatal care. The primary outcome measures were neonatal respiratory illnesses, NICU admission and length of stay.

    RESULTS: A total of 189 patients were recruited, 93 women in the intervention group and 96 as controls. Between the steroid and control groups, the mean gestation at CS was similar, 266.1 ± 3.2 days (38 weeks) vs. 265.8 ± 4.0 days (37+6 weeks), p = 0.53. The mean birthweight of infants was 3.06 ± 0.41 kg vs. 3.04 ± 0.37 kg, p = 0.71. Infants with respiratory morbidities were primarily due to transient tachypnea of newborn (9.7% vs. 6.3%), and congenital pneumonia (1.1% vs. 3.1%) but none had respiratory distress syndrome. Only four infants required NICU admission (2.2% vs. 3.1%, p = 0.63). Their average length of stay was not statistically different; 3.5 ± 2.1 days vs. 5.7 ± 1.5 days, p = 0.27.

    CONCLUSIONS: Elective CS at early term before 39 weeks was associated with a modest overall incidence of neonatal respiratory illness (10.1%) in this Asian population. Antenatal dexamethasone did not diminish infants needing respiratory support, NICU admission and length of stay.

  7. Juhan N, Abd Razak N, Zubairi YZ, Khattak MN, Naing NN
    Iran J Public Health, 2013 Sep;42(9):980-7.
    PMID: 26175969
    BACKGROUND: Cervical cancer is the third most common cancer among women in Malaysia. The objective of this study was to estimate the effect of explanatory variables on survival time of cervical cancer patients receiving treatment at a hospital in Malaysia.

    METHODS: In this retrospective record review study, cervical cancer data obtained from Hospital UniversitiSains Malaysia (HUSM) was analysed. The data comprises of 120 patients who had been diagnosed as cervical cancer between 1(st) July 1995 and 30(th) June 2007, and obtained treatment from the hospital. The outcome variable was survival time (in months) from cervical cancer diagnosis to death. A stratified Weibull model was applied to study the effect of explanatory variable on survival time when there was time-dependent covariate in the model.

    RESULTS: Stage of disease and metastases were important prognostic variables. However, metastasis had been stratified because this variable did not satisfy the proportional hazard assumption. In without metastasis stratum, patients who were diagnosed at stage III & IV are at 2.30 times the risk of death as those in stage I & II. Meanwhile, in with metastasis stratum, patients in stage III & IV group had 3.53 times the hazard faced by patients in stage I & II.

    CONCLUSION: The prognosis of cervical cancer patients was dependent upon the stage at diagnosis, after the stratification of the metastasis variable. A poorer prognosis on survival was observed for patients in stage III & IV than those in stage I & II.

  8. Abd Razak N, Yeap SK, Alitheen NB, Ho WY, Yong CY, Tan SW, et al.
    Integr Cancer Ther, 2020 8 25;19:1534735420935625.
    PMID: 32830560 DOI: 10.1177/1534735420935625
    Eupatorin is a polymethoxy flavone extracted from Orthosiphon stamineus and was reported to exhibit cytotoxic effects on several cancer cell lines. However, its effect as an anti-breast cancer agent in vivo has yet to be determined. This study aims to elucidate the potential of eupatorin as an anti-breast cancer agent in vivo using 4T1 challenged BALB/c mice model. In this article, BALB/c mice (20-22 g) challenged with 4T1 cells were treated with 5 mg/kg or 20 mg/kg eupatorin, while the untreated and healthy mice were fed with olive oil (vehicle) via oral gavage. After 28 days of experiment, the mice were sacrificed and blood was collected for serum cytokine assay, while tumors were harvested to extract RNA and protein for gene expression assay and hematoxylin-eosin staining. Organs such as spleen and lung were harvested for immune suppression and clonogenic assay, respectively. Eupatorin (20 mg/kg) was effective in delaying the tumor development and reducing metastasis to the lung compared with the untreated mice. Eupatorin (20 mg/kg) also enhanced the immunity as the population of NK1.1+ and CD8+ in the splenocytes and the serum interferon-γ were increased. Concurrently, eupatorin treatment also has downregulated the expression of pro-inflammatory and metastatic related genes (IL-1β. MMP9, TNF-α, and NF-κB). Thus, this study demonstrated that eupatorin at the highest dosage of 20 mg/kg body weight was effective in delaying the 4T1-induced breast tumor growth in the animal model.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links