Displaying all 7 publications

Abstract:
Sort:
  1. Lim TW, Ab Ghani SM, Mahmud M
    J Prosthet Dent, 2020 Dec 02.
    PMID: 33279159 DOI: 10.1016/j.prosdent.2020.06.034
    STATEMENT OF PROBLEM: Resin-bonded fixed partial dental prostheses (RBFPDPs) cemented at an increased occlusal vertical dimension (OVD) (the Dahl concept) to create space for a metal retainer remain controversial because of the lack of reported clinical studies. This study evaluated RBFPDPs by applying the Dahl concept.

    PURPOSE: The purpose of this retrospective study was to investigate the clinical factors affecting the occlusal re-establishment and short-term complications of RBFPDPs cemented at an increased OVD.

    MATERIAL AND METHODS: Occlusal re-establishment and clinical complications were reviewed in 109 participants (155 RBFPDPs) treated at the Faculty of Dentistry, Universiti Teknologi MARA from January 2013 to May 2018. Types of complications and risk factors were assessed from clinical data. Demographic factors, clinical factors, and prosthesis factors were distinguished and their association with occlusal re-establishment analyzed by using multiple regression analysis.

    RESULTS: A total of 155 RBFPDPs (42 anterior, 113 posterior) were placed in 109 participants. All achieved occlusal re-establishment, 89.9% complete occlusal re-establishment and 10.1% partial occlusal re-establishment, a minimum of 4 months after the RBFPDPs had been placed at an increased OVD. The design of the metal retainer coverage was found to be a significant factor affecting occlusal re-establishment and decementation (P

  2. Ab Ghani SM, Abdul Hamid NF, Lim TW
    Eur J Dent Educ, 2021 Aug 17.
    PMID: 34403561 DOI: 10.1111/eje.12712
    INTRODUCTION: Blended learning utilizes technology with reduced face-to-face time and promotes a student-centred learning environment that excites the learning process. However, studies on blended learning in fixed prosthodontics is still lacking. This study aimed to compare students' performance in easy and difficult level of fixed prosthodontic preclinical projects given by either blended learning or conventional teaching.

    METHODS: A cross-sectional study was conducted on 72 s-year dental students, who attended preclinical fixed prosthodontic training. Participants were randomly segregated into conventional teaching (n = 36) and blended learning (n = 36). All participants were evaluated for learning preferences using Visual-Aural-Read/Write-Kinesthetic (VARK) questionnaire and performed a project as their baseline skill assessment. They performed another two preclinical projects (easy and difficult level) after the allocated teaching approach. Learning preferences were analysed using Fisher's exact test and performance in preclinical projects were analysed with an independent t test (significant at p  .05) between groups. No significant differences found between both teaching approaches for easy (p = .319) and difficult projects (p = .339). In the blended learning group, no significant difference was found in both difficulty level of projects (p = .064).

    CONCLUSION: The participants performed equally on both teaching approaches. However, blended learning for preclinical fixed prosthodontics is anticipated as the new norm of learning, especially in the current pandemic with reduced face-to-face time.

  3. Vohra F, Al-Kheraif AA, Ab Ghani SM, Abu Hassan MI, Alnassar T, Javed F
    J Prosthet Dent, 2015 Sep;114(3):351-7.
    PMID: 26047803 DOI: 10.1016/j.prosdent.2015.03.016
    STATEMENT OF PROBLEM: Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear.

    PURPOSE: The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters.

    MATERIAL AND METHODS: The focus question addressed was, "Do zirconia implants maintain crestal bone levels and periimplant soft tissue health?" Databases were searched for articles from 1977 through September 2014 with different combinations of the following MeSH terms: "dental implants," "zirconium," "alveolar bone loss," "periodontal attachment loss," "periodontal pocket," "periodontal index." Letters to the editor, case reports, commentaries, review articles, and articles published in languages other than English were excluded.

    RESULTS: Thirteen clinical studies were included. In 8 of the studies, the CBL around zirconia implants was comparable between baseline and follow-up. In the other 5 studies, the CBL around zirconia implants was significantly higher at follow-up. Among the studies that used titanium implants as controls, 2 studies showed significantly higher CBL around zirconia implants, and in 1 study, the CBL around zirconia and titanium implants was comparable. The reported implant survival rates for zirconia implants ranged between 67.6% and 100%. Eleven studies selectively reported the periimplant inflammatory parameters.

    CONCLUSIONS: Because of the variations in study design and methodology, it was difficult to reach a consensus regarding the efficacy of zirconia implants in maintaining crestal bone levels and periimplant soft tissue health.

  4. Rahimi SN, Kassim MZ, Shamsul Anuar SA, Ab Ghani SM, Baharuddin IH, Lim TW
    J Indian Prosthodont Soc, 2018 Oct;18(Suppl 1):S11-S12.
    PMID: 30532402 DOI: 10.4103/0972-4052.244600
  5. Ab Ghani SM, Mohd Khairuddin PNA, Lim TW, Md Sabri BA, Abdul Hamid NF, Baharuddin IH, et al.
    Eur J Dent Educ, 2024 Feb;28(1):106-113.
    PMID: 37253116 DOI: 10.1111/eje.12925
    INTRODUCTION: The communication skills of clinicians are very crucial in providing better health outcomes for patients. Therefore, this study aimed to assess undergraduate dental students' communication skills in relation to their demographics and clinical setting using a three-perspective approach; the student, the patient and the clinical instructor perspective.

    METHODS: A cross-sectional study was conducted using validated modified-communication tools; Patient Communication Assessment Instruments (PCAI), Student Communication Assessment Instruments (SCAI) and Clinical Communication Assessment Instruments (CCAI) which included four communication domains. One hundred and seventy-six undergraduate clinical year students were recruited in this study whereby each of them was assessed by a clinical instructor and a randomly selected patient in two settings: Dental Health Education (DHE) and Comprehensive Care (CC) clinic.

    RESULTS: Comparing the three perspectives, PCAI yielded the highest scores across all domains, followed by SCAI and CCAI (p 

  6. Mustafa NWNA, Ahmad R, Ahmad Khushaini MA, Kamar Affendi NH, Ab Ghani SM, Tan SK, et al.
    ACS Biomater Sci Eng, 2024 Jan 08;10(1):405-419.
    PMID: 38040671 DOI: 10.1021/acsbiomaterials.3c01551
    This study assessed the corrosion resistance, intracutaneous reactivity, acute systemic toxicity, and in situ tissue effect of the implantation of porous NiTi fabricated by metal injection molding in animal models. For the intracutaneous reactivity study, five intracutaneous injections were administered per site with and without the tested extract in polar and nonpolar solutions. The extract was also delivered via intravenous and intraperitoneal routes for acute systemic toxicity. TiAl6 V4 (control) and porous NiTi were implanted in rabbit femora for a period of 13 weeks to evaluate the in situ tissue response. Corrosion was evaluated through open and cyclic polarization in PBS, while biocompatibility was investigated by assessing the general conditions, skin irritation score (edema and erythema), and histopathology. No active dissolution or hysteresis loop was observed in the corrosion study. None of the animals exhibited death, moribundity, impending death, severe pain, self-mutilation, or overgrooming. No edema was observed at injection sites. Only the positive control showed an erythematous reaction at 24, 48, and 72 h observations (p < 0.001). Porous NiTi showed a low in situ biological response for inflammation, neovascularization, and fibrosis in comparison to the control implant (p = 0.247, 0.005, and 0.011, respectively). Porous NiTi also demonstrated high pitting corrosion resistance while causing no acute hypersensitivity or acute systemic toxicity. The study concludes that porous NiTi implants were unlikely to cause local sensitization, acute systemic toxicity, or chronic inflammatory reactions in an animal model. Porous NiTi also exhibited osseointegration equivalent to Ti6AI4 V of known biocompatibility.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links