Displaying publications 81 - 100 of 132 in total

Abstract:
Sort:
  1. Kondo E, Merican AM, Yasuda K, Amis AA
    Arthroscopy, 2014 Mar;30(3):335-43.
    PMID: 24581258 DOI: 10.1016/j.arthro.2013.12.003
    The purpose of this study was to clarify the changes in the kinematics of the knee that result from isolated deficiency of the anteromedial (AM) or posterolateral (PL) bundle.
    Matched MeSH terms: Range of Motion, Articular
  2. Teo PC, Kassim AY, Thevarajan K
    J Orthop Surg (Hong Kong), 2013 Dec;21(3):340-6.
    PMID: 24366797
    To propose a novel method to measure the neck shaft angle and anteversion of the femur using anteroposterior and 45-degree oblique radiographs.
    Matched MeSH terms: Range of Motion, Articular
  3. Sulaiman AR, Munajat I, Mohd EF
    J Pediatr Orthop B, 2011 Nov;20(6):366-71.
    PMID: 21716140 DOI: 10.1097/BPB.0b013e32834920df
    Operative treatment for neglected fracture of lateral humeral condyle (LHC) is difficult because of contracted muscle, fibrous tissue formation, and indistinct bony edges. Its success depends on the ability to preserve blood supply during the surgery. We retrospectively reviewed eight cases of neglected fracture of LHC in children treated with open reduction with selected multiple 'V' lengthening of common extensor muscle and internal fixation. The patients were between 3 and 8 years of age. The period of neglect was between 3 and 20 weeks. Four patients with displacement of more than 10 mm and neglect for 5 weeks or more required lengthening of common extensor muscle aponeurosis. The follow-up assessments were between 1 and 6.3 years with a mean of 4.4 years. All patients had union by 2 months. They gained improvement of flexion range of motion between 60° and 120° with a mean of 86.3°. Loss of final range of motion compared with the normal side was between 5° and 35° with a mean of 10°. No patient had limitation of activities or pain. Six cases had excellent and two cases had good Dillon functional score. All patients had lateral condyle prominent with different severities. There was one mild avascular necrosis and one fishtail deformity. Both of them had almost full range of motion. All patients had early physeal closure, except one, who had only 1 year follow-up. There was no case of progressive valgus deformity. Children with neglected fracture of LHC would benefit from anatomical reduction and internal fixation through a proper exposure and if indicated combined with multiple 'V' lengthening of common extensor muscle aponeurosis. This is a level IV study.
    Matched MeSH terms: Range of Motion, Articular
  4. Arif M, Makundala V, Choon DSK
    Med J Malaysia, 2005 Jul;60 Suppl C:99-103.
    PMID: 16381292 MyJurnal
    We report on our early experiences with the Press Fit Condylar Rotating Platform (PFC-RP) total knee replacement prosthesis at University Malaya Medical Centre. This new prosthesis was introduced to Malaysia in 2001. It combines the rotating platform technology of Low Contact Stress (LCS) and the modularity of Press Fit Condylar (PFC) system. We performed 18 knee replacements using cruciate retaining prosthesis without patellar resurfacing in 10 patients and followed them up over a period of 16-month. A new operative strategy was developed to match the flexion and extension gaps. The pre- and post-operative assessments were made according to the American Knee Society Scores (AKSS). Post-operative pain relief, range of motion, knee score and functional score showed promising early results. The average knee rating improved from 28 to 91 (range 75-94). Average functional assessment improved from 26 to 82 (range 75-90). The radiographic assessments show correction of an average pre-operative varus of 140 to post-operative valgus of 50 (range 4-70). Early infection occurred in two knees. Both responded to aggressive debridement and antibiotics. Stiffness was encountered in one patient. There were no spinouts of the insert. We are satisfied that the implants are performing well at the one-year mark and will continue monitor this cohort.
    Matched MeSH terms: Range of Motion, Articular
  5. Merican AM, Ghosh KM, Baena FR, Deehan DJ, Amis AA
    Knee Surg Sports Traumatol Arthrosc, 2014 Mar;22(3):526-33.
    PMID: 23271038 DOI: 10.1007/s00167-012-2312-z
    PURPOSE: To study the effect of increasing patellar thickness (overstuffing) on patellofemoral kinematics in total knee arthroplasty and whether subsequent lateral retinacular release would restore the change in kinematics.

    METHODS: The quadriceps of eight fresh-frozen knees were loaded on a custom-made jig. Kinematic data were recorded using an optical tracking device for the native knee, following total knee arthroplasty (TKA), then with patellar thicknesses from -2 to +4 mm, during knee extension motion. Staged lateral retinacular releases were performed to examine the restoration of normal patellar kinematics.

    RESULTS: Compared to the native knee, TKA led to significant changes in patellofemoral kinematics, with significant increases in lateral shift, tilt and rotation. When patellar composite thickness was increased, the patella tilted further laterally. Lateral release partly corrected this lateral tilt but caused abnormal tibial external rotation. With complete release of the lateral retinaculum and capsule, the patella with an increased thickness of 4 mm remained more laterally tilted compared to the TKA with normal patellar thickness between 45° and 55° knee flexion and from 75° onwards. This was on average by 2.4° ± 2.9° (p 

    Matched MeSH terms: Range of Motion, Articular
  6. Rai SK, Sud AD, Kashid M, Gogoi B
    Malays Orthop J, 2020 Nov;14(3):66-72.
    PMID: 33403064 DOI: 10.5704/MOJ.2011.011
    Introduction: Osteosynthesis by plate fixation of humeral shaft fractures as a gold standard for fracture fixation has been proven beyond doubt. However, during conventional anterolateral plating Radial nerve injury may occur which can be avoided by applying plate on the medial flat surface. The aim of this study was to evaluate the results of application of plate on the flat medial surface of humerus rather than the conventional anterolateral surface.

    Materials and Methods: This study was conducted between Oct 2010 to Dec 2015. One-hundred-fifty fracture shafts of the humerus were treated with the anteromedial plating through the anterolateral approach.

    Results: One-hundred-fifty patients with a fracture shaft of the humerus were treated with anteromedial plating. Twenty were female (mean ±SD,28 years±4.5) and 130 were male (mean ± SD, 38 years±5.6). One hundred and forty-eight out of 150 (98.6%) patients achieved union at 12 months. Two of three patients developed a superficial infection, both of which were treated successfully by antibiotics and one developed a deep infection, which was treated by wound debridement, prolonged antibiotics with the removal of the plate and subsequently by delayed plating and bone grafting.

    Conclusion: In the present study, we applied plate on the anteromedial flat surface of humerus using the anterolateral approach. It is an easier and quicker fixation as compared to anterolateral plating because later involved much more dissection than a medial application of the plate and this application of plate on a medial flat surface, does not required Radial nerve exposure and palsy post-operatively. The significant improvement in elbow flexion without brachialis dissection is also a potential benefit of this approach. Based on our results, we recommend the application of an anteromedial plate for treatment of midshaft fractures humerus.

    Matched MeSH terms: Range of Motion, Articular
  7. Talib I, Sundaraj K, Lam CK
    Sci Rep, 2019 11 07;9(1):16166.
    PMID: 31700129 DOI: 10.1038/s41598-019-52536-4
    This study aimed to quantify the association of four anthropometric parameters of the human arm, namely, the arm circumference (CA), arm length (LA), skinfold thickness (ST) and inter-sensor distance (ISD), with amplitude (RMS) and crosstalk (CT) of mechanomyography (MMG) signals. Twenty-five young, healthy, male participants were recruited to perform forearm flexion, pronation and supination torque tasks. Three accelerometers were employed to record the MMG signals from the biceps brachii (BB), brachialis (BRA) and brachioradialis (BRD) at 80% maximal voluntary contraction (MVC). Signal RMS was used to quantify the amplitude of the MMG signals from a muscle, and cross-correlation coefficients were used to quantify the magnitude of the CT among muscle pairs (BB & BRA, BRA & BRD, and BB & BRD). For all investigated muscles and pairs, RMS and CT showed negligible to low negative correlations with CA, LA and ISD (r = -0.0001--0.4611), and negligible to moderate positive correlations with ST (r = 0.004-0.511). However, almost all of these correlations were statistically insignificant (p > 0.05). These findings suggest that RMS and CT values for the elbow flexor muscles recorded and quantified using accelerometers appear invariant to anthropometric parameters.
    Matched MeSH terms: Range of Motion, Articular
  8. Kosalishkwaran G, Parasuraman S, Singh DKJ, Natarajan E, Elamvazuthi I, George J
    Med Biol Eng Comput, 2019 Oct;57(10):2305-2318.
    PMID: 31444622 DOI: 10.1007/s11517-019-02026-6
    Degenerative disc disease (DDD) is a common condition in elderly population that can be painful and can significantly affect individual's quality of life. Diagnosis of DDD allows prompt corrective actions but it is challenging due to the absence of any symptoms at early stages. In studying disc degeneration, measurement of the range of motion (RoM) and loads acting on the spine are crucial factors. However, direct measurement of RoM involves increased instrumentation and risk. In this paper, an innovative method is proposed for calculating RoM, emphasizing repeatability and reliability by considering the posterior thickness of the spine. This is achieved by offsetting the position of markers in relation to the actual vertebral loci. Three geometrically identical finite element models of L3-L4 are developed from a CT scan with different types of elements, and thereafter, mesh element-related metrics are provided for the assessment of the quality of models. The model with the best mesh quality is used for further analysis, where RoM are within ranges as reported in literature and in vivo experiment results. Various kinds of stresses acting on individual components including facet joints are analysed for normal and abnormal loading conditions. The results showed that the stresses in abnormal load conditions for all components including cortical (76.67 MPa), cancellous (69.18 MPa), annulus (6.30 MPa) and nucleus (0.343 MPa) are significantly greater as compared to normal loads (49.96 MPa, 44.2 MPa, 4.28 MPa and 0.23 MPa respectively). However, stress levels for both conditions are within safe limits (167-215 MPa for cortical, 46 MPa for the annulus and 3 MPa for facets). The results obtained could be used as a baseline motion and stresses of healthy subjects based on their respective lifestyles, which could benefit clinicians to suggest corrective actions for those affected by DDD.
    Matched MeSH terms: Range of Motion, Articular
  9. Yoon KH, Kim JS, Park JY, Park SY, Kiat RYD, Kim SG
    Orthop J Sports Med, 2021 Feb;9(2):2325967120985153.
    PMID: 33709007 DOI: 10.1177/2325967120985153
    Background: There is currently no consensus on the optimal placement of the tibial tunnel for remnant-preserving posterior cruciate ligament (PCL) reconstruction.

    Purpose/Hypothesis: The purpose of this study was to compare the clinical and radiologic outcomes of remnant-preserving PCL reconstruction using anatomic versus low tibial tunnels. We hypothesized that the outcomes of low tibial tunnel placement would be superior to those of anatomic tibial tunnel placement at the 2-year follow-up after remnant-preserving PCL reconstruction.

    Study Design: Cohort study; Level of evidence, 3.

    Methods: We retrospectively reviewed the data for patients who underwent remnant-preserving PCL reconstruction between March 2011 and January 2018 with a minimum follow-up of 2 years (N = 63). On the basis of the tibial tunnel position on postoperative computed tomography, the patients were divided into those with anatomic placement (group A; n = 31) and those with low tunnel placement (group L; n = 32). Clinical scores (International Knee Documentation Committee subjective score, Lysholm score, and Tegner activity level), range of motion, complications, and stability test outcomes at follow-up were compared between the 2 groups. Graft signal on 1-year follow-up magnetic resonance imaging scans was compared between 22 patients in group A and 17 patients in group L.

    Results: There were no significant differences between groups regarding clinical scores or incidence of complications, no between-group differences in posterior drawer test results, and no side-to-side difference on Telos stress radiographs (5.2 ± 2.9 mm in group A vs 5.1 ± 2.8 mm in group L; P = .900). Postoperative 1-year follow-up magnetic resonance imaging scans showed excellent graft healing in both groups, with no significant difference between them.

    Conclusion: The clinical and radiologic outcomes and complication rate were comparable between anatomic tunnel placement and low tibial tunnel placement at 2-year follow-up after remnant-preserving PCL reconstruction. The findings of this study suggest that both tibial tunnel positions are clinically feasible for remnant-preserving PCL reconstruction.

    Matched MeSH terms: Range of Motion, Articular
  10. Mohd Khairuddin I, Sidek SN, P P Abdul Majeed A, Mohd Razman MA, Ahmad Puzi A, Md Yusof H
    PeerJ Comput Sci, 2021;7:e379.
    PMID: 33817026 DOI: 10.7717/peerj-cs.379
    Electromyography (EMG) signal is one of the extensively utilised biological signals for predicting human motor intention, which is an essential element in human-robot collaboration platforms. Studies on motion intention prediction from EMG signals have often been concentrated on either classification and regression models of muscle activity. In this study, we leverage the information from the EMG signals, to detect the subject's intentions in generating motion commands for a robot-assisted upper limb rehabilitation platform. The EMG signals are recorded from ten healthy subjects' biceps muscle, and the movements of the upper limb evaluated are voluntary elbow flexion and extension along the sagittal plane. The signals are filtered through a fifth-order Butterworth filter. A number of features were extracted from the filtered signals namely waveform length (WL), mean absolute value (MAV), root mean square (RMS), standard deviation (SD), minimum (MIN) and maximum (MAX). Several different classifiers viz. Linear Discriminant Analysis (LDA), Logistic Regression (LR), Decision Tree (DT), Support Vector Machine (SVM) and k-Nearest Neighbour (k-NN) were investigated on its efficacy to accurately classify the pre-intention and intention classes based on the significant features identified (MIN and MAX) via Extremely Randomised Tree feature selection technique. It was observed from the present investigation that the DT classifier yielded an excellent classification with a classification accuracy of 100%, 99% and 99% on training, testing and validation dataset, respectively based on the identified features. The findings of the present investigation are non-trivial towards facilitating the rehabilitation phase of patients based on their actual capability and hence, would eventually yield a more active participation from them.
    Matched MeSH terms: Range of Motion, Articular
  11. Sun C, Zhang X, Lee WG, Tu Y, Li H, Cai X, et al.
    J Orthop Surg Res, 2020 Aug 05;15(1):297.
    PMID: 32758250 DOI: 10.1186/s13018-020-01823-2
    BACKGROUND: The infrapatellar fat pad (IPFP) or Hoffa's fat pad is often resected during total knee arthroplasty in order to improve visibility. However, the management of the IPFP during total knee arthroplasty (TKA) is the subject of an ongoing debate that has no clear consensus. The purpose of this review was to appraise if resection of the IPFP affects clinical outcomes.

    METHODS: We conducted a meta-analysis to identify relevant randomized controlled trials involving infrapatellar fat pad resection and infrapatellar fat pad preservation during total knee arthroplasty in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database, up to March 2020.

    RESULTS: Nine randomized controlled trials, involving 783 TKAs (722 patients), were included in the systematic review. Outcome measures included patellar tendon length (PTL), Insall-Salvati ratio (ISR), rate of anterior knee pain, Knee Society Scores (KSS), and knee range of motion. The meta-analysis identified a trend toward the shortening of the patellar tendon with IPFP resection at 6 months (P = 0.0001) and 1 year (P = 0.001). We found no statistical difference in ISR (P = 0.87), rate of anterior knee pain within 6 months (p = 0.45) and 1 year (p = 0.38), KSS at 1 year (p = 0.77), and knee range of motion within 6 months (p = 0.61) and 1 year (0.46).

    CONCLUSION: Based on the available level I evidence, we were unable to conclude that one surgical technique of IPFP can definitively be considered superior over the other. More adequately powered and better-designed randomized controlled trial (RCT) studies with long-term follow-up are required to produce evidence-based guidelines regarding IPFP resection.

    Matched MeSH terms: Range of Motion, Articular
  12. Singh N, Pandey CR, Tamang B, Singh R
    Malays Orthop J, 2020 Jul;14(2):64-71.
    PMID: 32983379 DOI: 10.5704/MOJ.2007.014
    Introduction: The study was conducted to evaluate the efficacy of arthroscopic debridement, microfracture and plasma rich in growth factor (PRGF) injection in the management of type V (Scranton) osteochondral lesions of talus and its role in healing the subchondral cyst and cessation of progression of ankle osteoarthritis.

    Material and Methods: This is a prospective case series conducted on patients who were diagnosed with type V osteochondral lesions of talus. All the cases were treated with arthroscopic debridement, microfracture, and PRGF injections. The patients were evaluated for the healing of subchondral cysts and progression of osteoarthritis with radiography (plain radiographs and computerised tomography Scan). Also, the patients' outcome was evaluated with Quadruple Visual Analogue Scale, Ankle Range of Motion, Foot and Ankle Disability Index, Foot and Ankle Outcome Instrument and a Satisfaction Questionnaire.

    Results: Five male patients underwent arthroscopic debridement, microfracture and PRGF injection for type V osteochondral lesion of talus. The mean age of patients was 27.4 years (19-47 years). All the patients gave history of minor twisting injury. Subchondral cyst healing was achieved in all patients by six months post-surgery. However, four out of five patients had developed early osteoarthritic changes of the ankle by their last follow-up [mean follow-up 29 months (ranged 15-36 months)]. Despite arthritic changes, all the patients reported 'Good' to 'Excellent' results on satisfaction questionnaire and Foot and Ankle Disability Index and could perform their day to day activities including sports.

    Conclusion: Arthroscopic debridement, microfracture, and PRGF causes healing of the subchondral cyst but does not cause cessation of progression to osteoarthritis of ankle in type V osteochondral defects of talus. However, despite progress to osteoarthritis, patient satisfaction post-procedure is good to excellent at short-term follow-up.

    Matched MeSH terms: Range of Motion, Articular
  13. Sam CX, Anwar AZ, Ahmad AR, Solayar GN
    Malays Orthop J, 2021 Mar;15(1):119-123.
    PMID: 33880158 DOI: 10.5704/MOJ.2103.018
    Introduction: Reverse total shoulder arthroplasty provides a surgical alternative to standard total shoulder arthroplasty for the treatment of cuff tear arthropathy, arthritis and fracture sequelae. This study aimed to assess the short-term outcomes following reverse total shoulder arthroplasty for patients in a large public hospital in Malaysia.

    Materials and Methods: We identified and performed five primary reverse total shoulder arthroplasties between 1 May 2019 and 1 June 2020. All patients were contactable and available for analysis. Assessment of functional outcomes was performed using the Constant-Murley score, the patient satisfaction score (PSS), and imaging studies. The mean follow-up from operation to the time of reporting was 9.6 months (range, 3 to 14 months).

    Results: The median age for our patients was 58 years (±11.91). The most common indication for surgery was post-traumatic arthritis, followed by rotator cuff arthropathy and osteoarthritis. The mean Constant score improved from 9.0 pre-operatively to 52.3 post-operatively at a mean of 9.6 months. The majority of the patients were satisfied with the surgery as the post-operative range of motion, especially anterior elevation and abduction, improved in four of our patients and there were no short-term complications, for example, of infection or revisions, reported at the last follow-up.

    Conclusion: This study has shown that reverse total shoulder arthroplasty can yield good short-term outcomes for the treatment of complex shoulder problems in addition to cuff tear arthropathy. It should be considered a treatment for rotator cuff tears, severe arthritis and ≥ 3 parts proximal humeral fractures.

    Matched MeSH terms: Range of Motion, Articular
  14. Loh, Li Loong, Wong, Kai Ann, Zamzuri Zakaria@Mohamad
    MyJurnal
    Synovial osteochondromatosis is an unusual, rare and benign tumour. This disease is characteristically monoarticular, most commonly found in knee joint, however it is rarely found in the elbow. A 49-year-old Indian man presented to hospital with a 6-month history of pain, swelling, intermittent locking, loss of range of motion of right elbow and a considerable size of elbow with no recollection of associated trauma. Plain radiographs of right elbow showed numerous radiopaque round and oval loose bodies within the right elbow joints. Computer Tomographic (CT) scan showed multiple bony mass within the right elbow joint. Arthroscopic synovectomy, debridement, excisional biopsy and loose body removal combined with miniarthrotomy of the right elbow was performed due to limited exposure for removal of larger loose bodies. Histopathological examination of the tissue sample is consistent with the diagnosis of synovial osteochondromatosis. The clinical and radiological evaluation at 6th month postoperatively showed marked reduction in the volume of the elbow, further improvement of elbow range of motion of this patient and the Mayo elbow performance score before surgery and at 6 months postoperative, with an increase from 50 to 80 points. Synovial osteochondromatosis of the joints is a rare condition. The signs and symptoms are not specific and may be suggestive of other pathology conditions. Arthroscopic synovectomy and removal of loose body is the standard operative procedure till today. However, combination of arthroscopy and miniarthrotomy in cases of large loose bodies may provide a good clinical and functional outcome.
    Matched MeSH terms: Range of Motion, Articular
  15. Ponvel, P., Devinder K.A. Singh, Yan Hang, M., Muniandy Y., Mokhtar, S.
    Medicine & Health, 2018;13(2):122-132.
    MyJurnal
    While socio-demographic, physical and other factors are associated with neck pain, there is scanty literature about how these factors are associated with disability in adults suffering from this condition. We aimed to determine the socio-demographic and physical (strength and range of motions) related factors of disability in adults with non-specific chronic neck pain. A total of 34 adults with neck pain, with mean age 55 (10.80) years from a physiotherapy clinic in a teaching hospital participated in this study. Socio-demographic details such as body mass index (BMI), current employment status, hours of exercise done a week were obtained. Severity of pain was evaluated using the Numerical Rating Scale (NRS). Disability level was assessed using Neck Disability Index. Cervical range of motion was measured using the Cervical Range of Motion device. A hand dynamometer was used to measure the dominant hand grip muscle strength. The data was analyzed using descriptive and stepwise linear regression analysis. More than half the participants were females, above 50 years, in the overweight group (BMI>25 kg/m2), currently unemployed and had severe neck pain (NRS >7). Handgrip strength was the only factor found to be significantly (p
    Matched MeSH terms: Range of Motion, Articular
  16. Devnani AS
    PMID: 15685053
    In children with delayed presentation of displaced supracondylar fractures, closed or open reduction with K-wire fixation risks complications. Gradually reducing the fracture with traction potentially reduces these risks. An unacceptable deformity can be corrected later by an osteotomy. This concept was used for 28 children, with an average age of 7 years 6 months, who presented after an average delay of 5.6 days. Their stay in the hospital was 14 days on average. At followup (average, 24 months), five children (18%) who had cubitus varus greater than 10 degrees had corrective osteotomy. There were no additional neurovascular injuries after treatment. The results are comparable with other methods of treatment.
    Matched MeSH terms: Range of Motion, Articular
  17. Vijayakumar, P., Leonard, H.J., Ayiesah, H.R.
    MyJurnal
    Traumatic knee crush injuries of degloving nature carries a greater risk for the multitude of complications rendering emergency surgical intervention the treatment of choice in the majority of such injuries. These types of injuries commonly result in a unique post- operative complication such as arthrofibrosis and it presents overly challenge for Physiotherapists managing it. In this retrospective single-case report, we describe the challenges of in – and out- patient physiotherapy treatment planning for a 16-year old boy throughout the continuum of care for his knee arthrofibrosis following a series of surgical procedures. As result of his complex medical situation, the time-specific physiotherapy intervention during the immediate post-operative period failed to improve our patient’s knee function. The knee function with regard to range of motion ( especially extension), muscle strength(quadriceps) improved considerably with the adoption of an aggressive physiotherapy intervention approach that included specific quadriceps muscle strengthening, joint mobilization (rotation/traction) in sitting position with legs over the edge of table and contract-relax quadriceps stretching in prone position using theraband.
    Matched MeSH terms: Range of Motion, Articular
  18. Mohd Sharif NA, Goh SL, Usman J, Wan Safwani WKZ
    Phys Ther Sport, 2017 Nov;28:44-52.
    PMID: 28673759 DOI: 10.1016/j.ptsp.2017.05.001
    BACKGROUND: Knee sleeves are widely used for the symptomatic relief and subjective improvements of knee problems. To date, however, their biomechanical effects have not been well understood.

    OBJECTIVE: To determine whether knee sleeves can significantly improve the biomechanical variables for knee problems.

    METHOD: Systematic literature search was conducted on four online databases - PubMed, Web of Science, ScienceDirect and Springer Link - to find peer-reviewed and relevant scientific papers on knee sleeves published from January 2005 to January 2015. Study quality was assessed using the Structured Effectiveness Quality Evaluation Scale (SEQES).

    RESULTS: Twenty studies on knee sleeves usage identified from the search were included in the review because of their heterogeneous scope of coverage. Twelve studies found significant improvement in gait parameters (3) and functional parameters (9), while eight studies did not find any significant effects of knee sleeves usage.

    CONCLUSION: Most improvements were observed in: proprioception for healthy knees, gait and balance for osteoarthritic knees, and functional improvement of injured knees. This review suggests that knee sleeves can effect functional improvements to knee problems. However, further work is needed to confirm this hypothesis, due to the lack of homogeneity and rigor of existing studies.

    Matched MeSH terms: Range of Motion, Articular
  19. Yin Wei CC, Haw SS, Bashir ES, Beng SL, Shanmugam R, Keong KM
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017690656.
    PMID: 28219305 DOI: 10.1177/2309499017690656
    OBJECTIVE: To compare construct stiffness of cortical screw (CS)-rod transforaminal lumbar interbody fusion (TLIF) construct (G2) versus pedicle screw (PS)-rod TLIF construct (G1) in the standardized porcine lumbar spine.

    METHODS: Six porcine lumbar spines (L2-L5) were separated into 12 functional spine units. Bilateral total facetectomies and interlaminar decompression were performed for all specimens. Non-destructive loading to assess stiffness in lateral bending, flexion and extension as well as axial rotation was performed using a universal material testing machine.

    RESULTS: PS and CS constructs were significantly stiffer than the intact spine except in axial rotation. Using the normalized ratio to the intact spine, there is no significant difference between the stiffness of PS and CS: flexion (1.41 ± 0.27, 1.55 ± 0.32), extension (1.98 ± 0.49, 2.25 ± 0.44), right lateral flexion (1.93 ± 0.57, 1.55 ± 0.30), left lateral flexion (2.00 ± 0.73, 2.16 ± 0.20), right axial rotation (0.99 ± 0.21, 0.83 ± 0.26) and left axial rotation (0.96 ± 0.22, 0.92 ± 0.25).

    CONCLUSION: The CS-rod TLIF construct provided comparable construct stiffness to a traditional PS-rod TLIF construct in a 'standardized' porcine lumbar spine model.

    Matched MeSH terms: Range of Motion, Articular
  20. Goki-Kamei GK, Norimasa-Matsubara NM, Teruyasu-Tanaka TT, Koji-Natsu KN, Toshihiro-Sugioka TS
    Malays Orthop J, 2017 Mar;11(1):60-63.
    PMID: 28435577 DOI: 10.5704/MOJ.1703.004
    Intra-articular synovial haemangioma of the knee is a benign tumour. However, diagnostic delay leads to degenerative changes in the cartilage and osteoarthritis due to recurrent haemarthrosis. Therefore, treatment should be performed immediately. We report the case of a localized synovial haemangioma arising from the medial plica in a 38-year old female presenting with pain and restricted range of motion in the right knee joint. Initially, we diagnosed this case as a localized pigmented villonodular synovitis (LPVS) based on MRI and arthroscopic findings and performed only arthroscopic en bloc excision of the mass and synovectomy around the mass for diagnostic confirmation. Fortunately, there was no difference in the treatment approaches for LPVS and localized haemangioma and the synovial haemangioma had not recurred at the 3-month postoperative follow-up with MRI. The patient's clinical symptoms resolved and had not relapsed two years after surgery.
    Study site: Department of Orthopaedics, Miyoshi Central Hospital, Miyoshi, Japan
    Matched MeSH terms: Range of Motion, Articular
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links