SUBJECTS/METHODS: A semi-structured face-to-face interview was conducted among 15 dietitians from selected public hospitals, primary care clinics, and teaching hospitals in Malaysia. Inductive thematic analysis of the responses was conducted using NVivo version 12 software.
RESULTS: Most dietitians used physical education tools including the healthy plate model, pamphlets, food models, and flip charts. These tools were perceived as important as they facilitate the nutrition assessment process, deliver nutrition intervention, and are time efficient. However, dietitians described the current educational tools as impersonal, outdated, limited in availability due to financial constraints, unhandy, and difficult to visualise. Alternatively, they strongly favoured digital education tools that provided instant feedback, utilised an automated system, included a local food database, were user-friendly, developed by experts in the field, and seamlessly integrated into the healthcare system.
CONCLUSION: Presently, although dietitians have a preference for digital educational tools, they heavily rely on physical nutrition education tools due to their availability despite the perception that these tools are outdated, impersonal, and inconvenient. Transitioning to digital dietary education tools could potentially address these issues.
METHODS: This was a cross sectional study involving 222 cases recruited from National Institute of Forensic Medicine (NIFM) Hospital Kuala Lumpur (HKL) and Department of Forensic Medicine Hospital Sungai Buloh (HSgB) for a period of 15 months, from December 2012 to April 2014. Sociodemographic and autopsy findings, including the cause and manner of death were documented.
RESULTS: Male and female subjects aged 18-70 years were recruited. Males contributed to 86% of the total subjects and comprised 61% of young adults. Road traffic accidents were the primary cause of death, contributing almost 50% of the subjects. One third of the cases comprised of death due to natural causes, wherein almost 75% of the subjects within this category succumbed to sudden cardiac death. Coronary artery disease (CAD) contributed to 60% of the sudden cardiac death (SCD). Single and double-vessel diseases were the most common pattern of atherosclerosis. In almost 80% of CAD cases, atherosclerosis affected the left anterior descending artery (LAD).
CONCLUSION: Cardiovascular diseases were the most significant natural cause of sudden death with a staggering figure of 75%. CAD was the single most commonly encountered pathology within the SCD. Most cases presented with single and double-vessel diseases, observed in all subjects, as well as the young adult population.
METHOD: We simulate the CT head examination using a water phantom with a standard protocol (120 kVp/180 mAs) and a low dose protocol (100 kVp/142 mAs). The table height was adjusted to simulate miscentering by 5 cm from the isocenter, where the height was miscentered superiorly (MCS) at 109, 114, 119, and 124 cm, and miscentered inferiorly (MCI) at 99, 94, 89, and 84 cm. Seven circular regions of interest were used, with one drawn at the center, four at the peripheral area of the phantom, and two at the background area of the image.
RESULTS: For the standard protocol, the mean CNR decreased uniformly as table height increased and significantly differed (p
METHODS: In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review.
RESULTS: The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study.
CONCLUSION: Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.