Doping is the key feature in semiconductor device fabrication. Many strategies have been discovered for controlling doping in the area of semiconductor physics during the past few decades. Electrical doping is a promising strategy that is used for effective tuning of the charge populations, electronic properties, and transmission properties. This doping process reduces the risk of high temperature, contamination of foreign particles. Significant experimental and theoretical efforts are demonstrated to study the characteristics of electrical doping during the past few decades. In this article, we first briefly review the historical roadmap of electrical doping. Secondly, we will discuss electrical doping at the molecular level. Thus, we will review some experimental works at the molecular level along with we review a variety of research works that are performed based on electrical doping. Then we figure out importance of electrical doping and its importance. Furthermore, we describe the methods of electrical doping. Finally, we conclude with a brief comparative study between electrical and conventional doping methods.
The early detection of damaged (partially broken) outdoor insulators in primary distribution systems is of paramount importance for continuous electricity supply and public safety. Unmanned aerial vehicles (UAVs) present a safer, autonomous, and efficient way to examine the power system components without closing the power distribution system. In this work, a novel dataset is designed by capturing real images using UAVs and manually generated images collected to overcome the data insufficiency problem. A deep Laplacian pyramid-based super-resolution network is implemented to reconstruct high-resolution training images. To improve the visibility of low-light images, a low-light image enhancement technique is used for the robust exposure correction of the training images. A different fine-tuning strategy is implemented for fine-tuning the object detection model to increase detection accuracy for the specific faulty insulators. Several flight path strategies are proposed to overcome the shuttering effect of insulators, along with providing a less complex and time- and energy-efficient approach for capturing a video stream of the power system components. The performance of different object detection models is presented for selecting the most suitable one for fine-tuning on the specific faulty insulator dataset. For the detection of damaged insulators, our proposed method achieved an F1-score of 0.81 and 0.77 on two different datasets and presents a simple and more efficient flight strategy. Our approach is based on real aerial inspection of in-service porcelain insulators by extensive evaluation of several video sequences showing robust fault recognition and diagnostic capabilities. Our approach is demonstrated on data acquired by a drone in Swat, Pakistan.
A new approach to controlling the flow of a plasmatic electron packet at the interface between metallic and dielectric layers is described. The proposed metamaterial structure operates in the optical frequency range and can be used as a digital processing filter. It exhibits two double negative resonances and one special passband region, while the existence of a metal-dielectric nano-tunnel enhances electromagnetic wave-metal interactions. The structural arrangement of this metamaterial coupled with the tunnel layer can effectively control the electric field and allows digital encoding of electron packets.
The work aimed to study the potential in producing a system with high microalgal protein recovery and separation by utilizing a one-step or integrated downstream process. This in turn enables green biorefinery of protein, contributing to circular bioeconomy whereby less energy, labor, and cost are required for the process. By utilizing electric three phase partitioning flotation system, high protein recovery yield, R of 99.42 ± 0.52% and high separation efficiency, E of 52.72 ± 0.40% system was developed. Scaling up also showed high protein recovery yield with R value of 89.13 ± 1.56%. Total processing duration (extraction, separation, and purification) was also significantly reduced to 10 min. This system showed remarkable potential in reducing processing time, alternatively cost of production, benefiting microalgal downstream processing. Concisely, through this system, microalgal bioprocessing will no longer be complex allowing a wide array of potentials for further studies in this field.
Impact of pulsed electric field (PEF) assisted process on preparation of custard apple leaf extract (CALE) using ethanol (70%, v/v) was studied. Different electric field strengths (2-6 kV/cm), pulse numbers (100-300 pulses) with specific energies (45-142 kJ/kg) for 2.5 to 5 min were implemented. Cell disintegration index was higher in CALE when PEF 6 kV/cm, 300 pulses, 142 kJ/kg for 5 min was applied. Extraction yield was higher (+5.2%) than the untreated counterpart (13.28%). Chlorophyll A and B contents were negligible in PEF pre-treated CALE. PEF improved radical scavenging activities assessed by DPPH, ABTS radical scavening activities and FRAP. The antibacterial properties of CALE against Staphylococcus aureus and Escherichia coli were highest. Purpureacin 2 and rutin were abundant in PEF pre-treated CALE. Therefore PEF was the potential aid in augmenting extraction yield and bioactivities of the extract from custard apple leaves.
The electrical resistivity and flexural strength of plastic composites reinforced with pineapple leaf particles (PCPLP) is presented. PCPLP were produced using different plastic materials; Polyethylene (PE) and Polypropylene (PP), and different plastic pineapple leaf particle ratios; 50:50 and 70:30. The PCPLP were tested and evaluated with respect to electrical resistivity and flexural strength according to ASTM D257 and D790, respectively. The results indicate that PCPLP made from PP exhibits better electrical resistance than PE, which may be attributed to the better frequency insulation behaviour ofPP. PCPLP using the higher ratio of 70:30 also exhibited better electrical resistance than the lower 50:50 ratio. Cellulose materials inherently influence the electrical resistance of plastic composites, due to their natural propensity to absorb moisture. The PCPLP produced using a ratio of 50:50 for both PP and PE composites exhibited better MOE results than the 70:30 composites, however the converse is true with respect to the MOR. MOE of PCPLP was increased with increasing pineapple leaf particles content due to the greater matrix stiffness of this natural particle with respect to plastic matrix. However, high percentage offiller particles in the matrix (70:30 ratio) has reduced the toughness in the composite structure due to the lost ofphysical contact between high accumulated particles.
The paper focused on the examination and testing of local exhaust ventilation (LEV) systems at one of Electrical Company to check the transport velocity whether it meet the recommended American Governmental Industrial Hygienist (ACGIH) Standard. The industrial hygiene approaches, AREC (Anticipating, Recognize, Evaluate and Control) were adopted in this study. This is to ensure that the LEV system installed has the optimum efficiency to extract out the contaminants from the workstation. Objective of this study is to make comparison with previous and current monitoring data. The efficiency and the other parameter measured will be the main source to analyze for the particular applications. The differential of data was discussed and several recommendations are proposed to make sure the LEV system performance is excellent.
A major source of contemporary power is a Coal-fired Power Plant. These power plants have the capacity to continuously supply electricity to almost 500,000 residential and business units. An essential component of a Coal-fired Power plant is automation. A feature of this automation is an Intelligent System developed for the Power Plant. These Intelligent Systems have different configurations and design. This research studies the various Intelligent Monitoring Interfaces developed for Coal-fired Power Plant Trips, their advantages, disadvantages and proposes a new Intelligent Monitoring Interface that would alleviate the disadvantages of the existing systems. Current systems that use Neural Network models are investigated. The improved Intelligent Monitoring Interface as proposed in this paper is a modification of the existing monitoring system for the Coal-fired Power Plant Boiler Trips. It is expected to improve the overall system by implementing remote accessibility and interactability between the plant operator and the control system interface. The interface will also assist the operator by providing guidelines to troubleshoot the identified trips and the remote server application will allow data collected to be viewed anytime, anywhere.
Detailed geophysical investigations have been carried out using integrated geophysical methods with a view to characterising the subsurface lithologic features that might indicate suitable places for structural developments. An overview of the subsurface resistivity distribution has been achieved employing 8Vertical Electrical Soundings with the Schlumberger array and 4 2D resistivity imaging using Wenner array. In order to constrain the results of the electrical resistivity methods, we carried out a ground magnetic survey along E-W direction using the Proton precession magnetometer at 1m sampling interval. Analysis of well logs data available and VES results showed 4 to 5 geoelectric layers corresponding to sand, clayey sand, clay, silty sand and sandy clay. The 2D resistivity imaging sections showed relative decrease of apparent resistivity with depth implying a geological transition from sand with high resistivity value of about 508Ωm to clay with low resistivity value 16Ωm at depths of 0-20m and 25-50m respectively. The magnetic profiles showed that the study area was characterised by short wavelengths and amplitudes ranging from –3800 to 700 nT. The highs and lows of the magnetic responses occasioned by lithological variations and structural features were magnetically resolved. In view of the identified subsurface structures, the suggested depth to the competent layer is about 20m for low to medium structures while above 50m would be suitable for heavy or massive engineering structures. The use of integrated geophysical methods for the delineation, identification and imaging of the subsurface geological structures which could provide clues to the nature and type of foundation suitable for the development of the study area has been successfully achieved.
Patient undergoes orthodontic treatment with fixed appliances have more plaque
retentive area compare to normal person. Therefore, this patient requires higher standard of oral
hygiene care. One of adjunctive cleaning device for oral hygiene care is water irrigator. There are
several types of water irrigator available in the market such as syringe type, electricity and battery
operated. However, the problem is the available water irrigators are expensive. (Copied from article).
Top-Oil Temperature (TOT) is one of the basic components to estimate the Hot-Spot temperature (HST) of the transformers. This paper presents an alternative TOT model based on the heat transfer theory that utilises Nonlinear Thermal Resistance (NTR) and Lumped Capacitance (LC) approaches. It is applied in a thermal-electrical analogy and the heat transfer equivalent equation is determined. This model is tested on a measured TOT of 250 MVA ONAF and 400 MVA ONAF transformers obtained from IEC 60076-7 and previous research. A comparison of TOT is carried out with the existing models IEC 60076-7 exponential and IEEE Loading Guide clause 7 methods. It is found that the thermal model based on the NTR and LC approach could determine the measured TOT closer than the existing methods available in the standards.
In this paper, the challenge of harmonic injection mitigation becomes critical with the massive use of inverters in electrical distribution systems that has been discussed and analyzed. Currently, between the inverter and the grid, L, LC or LCL filters is often used to mitigate the current harmonic. Further, filter connection in both delta-to-star or star-to-delta transformer for state space model of LC filter couplings with impedance is obtained in this paper and it also talked about the different passive damping techniques that been used to suppress the resonance effect on the filter. The effect of series and parallel damping resistor techniques that impact filtering and stability are also been analyzed and discussed. At the end, the simulation results show that LCL filter with parallel damping resistor achieves best performance compared on those for L, LC, or LCL with series damping resistor while at the same time enhancing the smoothness of the signal output while at the same time reducing the percentage of total harmonic distortion between inverter-grid connection.
This paper presents the chaotic pulse train (CPT) waveforms of the vertical electric field generated by lightning observed in Malaysia. Focusing on the position where these electric field changes occur in a number of cloud to ground (CG) flashes, these CPTs were detected in different ways of occurrences, durations, intensities and amplitudes. Seventy-six chaotic pulse trains were found in this study from a sum of 172 CG flash records from three thunderstorm days. The fast field antenna was employed to do the field measurements. As opposed to the typical occurrence of chaotic pulse trains prior to subsequent strokes as reported in the literature, this study has found chaotic pulse trains occurring in different places along the CG electric field waveforms.
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage across all the DC-link capacitors. However, PI technique performs poorly with high overshoot and significant time delay under dynamic state conditions, as its parameters are difficult to be tuned without requiring complete knowledge of the designated system. Although FLC technique has been developed to overcome limitations of PI technique, it is mostly developed with high complexity thereby increases computational burden of the designed controller. This paper presents a fuzzy-based DC-link capacitor voltage regulation algorithm with reduced computational efforts to enhance performance of three-phase three-level neutralpoint diode clamped (NPC) inverter-based SAPF in overall DC-link voltage regulation. The proposed method is called effort-reduction FLC technique. The proposed algorithm is developed and evaluated in MATLAB-Simulink. Moreover, conventional algorithm with PI technique is tested for comparison purposes. Simulation results have confirmed improvement achieved by the proposed algorithm in comparison to the conventional algorithm.
In this paper, cap and pin porcelain insulator was studied under an environment with different levels
of humidity. The electric field strength and voltage distribution profile along the insulator string was
simulated using a computational software package. In this study, ANSYS Maxwell based on the Finite
Element Method (FEM) was used to simulate the short standard insulator string. The short standard
insulator string was modelled as a five-unit cap and pin porcelain insulator that was stacked according
to the IEC 60383 standard. Different humidity levels measured using relative humidity is applied to
the insulator. From this simulation, the locations within the insulator under high electric field stress are
identified when different humidity is applied.
Preventive tests and diagnosis of in-service power transformer are important for early fault prediction and increased reliability of electricity supply. However, some existing diagnostic techniques require transformer outage before the measurement can be performed and need expert knowledge and experiences to interpret the measurement results. Other measurement techniques such as chemical analyses of insulating oil may cause significant variance to measurement results due to different practices in oil sampling, storage, handling and transportation of oil. A cost-effective measuring technique, which is simple, providing fast and an accurate measurement results, is therefore highly required. The extended application of Polarisation and Depolarisation (PDC) measurement for characterisation of different faults conditions in-service power transformer has been presented in this paper. Earlier studies on polarisation and depolarisation current of oil samples from in-service power transformer shows that depolarisation has provided significant information about the change of material properties due to faults in power transformer. In this paper, a new approach based on Depolarisation Current Ratio Index (DRI) was developed for identifying and classifying different transformer fault conditions. The DRI at time interval of 4s to 100s was analysed and the results show that DRI of depolarisation current between 5/100s and 10/100s provides higher correlation on the incipient faults in power transformer.
This paper discusses the effect of jet impingement of water on a photovoltaic thermal (PVT) collector and compound parabolic concentrators (CPC) on electrical efficiency, thermal efficiency and power production of a PVT system. A prototype of a PVT solar water collector installed with a jet impingement and CPC has been designed, fabricated and experimentally investigated. The efficiency of the system can be improved by using jet impingement of water to decrease the temperature of the solar cells. The electrical efficiency and power output are directly correlated with the mass flow rate. The results show that electrical efficiency was improved by 7% when using CPC and jet impingement cooling in a PVT solar collector at 1:00 p.m. (solar irradiance of 1050 W/m² and an ambient temperature of 33.5 °C). It can also be seen that the power output improved by 36% when using jet impingement cooling with CPC, and 20% without CPC in the photovoltaic (PV) module at 1:30 p.m. The short-circuit current ISC of the PV module experienced an improvement of ~28% when using jet impingement cooling with CPC, and 11.7% without CPC. The output of the PV module was enhanced by 31% when using jet impingement cooling with CPC, and 16% without CPC.
In this paper, we present a novel compact, coplanar, tag antenna design for metallic objects. Electrically small antenna has designed for a UHF RFID (860-960 MHz) based on a proximity-coupled feed through. Furthermore, two symmetrical Via-loaded coplanar grounds fed by a U-shaped inductively coupled feed through an embedded transmission line. This configuration results in an antenna with dimensions of 31 × 19.5 × 3.065 mm3 at 915 MHz, and the total gain for the antenna is 0.12 dBi. The Via-loaded coplanar and U-shaped inductively coupled feeds allow the antenna to provide flexible tuning in terms of antenna impedance. In addition, a figure of merit is applied for the proposed tag antenna, and the results are presented. The read range is measured to be 4.2 m, which is very close to simulated values. This antenna measurement shows very good agreement with simulations.
Semiconductor metal oxide (SMO) as a sensing layer for gas detection has been widely used. Many researches have been performed to enhance the sensing performance including its sensitivity, reliability and selectivity. Electrical sensors that use resistivity as an indicator of its sensing are popular and well established. However, the optical based sensor is still much to explore in detecting gas. By integrating it with SMO, the sensor offers good alternative to overcome some drawbacks from electrical sensors.
Conventional lateral and vertical n-channel MOS transistors with channel length in the range of 100nm to 50nm have been systematically investigated by means of device simulation. The comparison analysis includes critical parameters that govern device performance. Threshold voltage VT roll-off, leakage current Ioff, drain saturation current IDsat and sub-threshold swing S were analyze and compared between the device. Due to double gate (DG) structure over the side of silicon pillar a better electrostatics potential control of channel is obtained in vertical device shown by an analysis on VT roll-off. A two decade higher of Ioff in planar device is observed with Lg=50nm. A factor of three times larger IDsat is observed for vertical MOSFETs compared to planar device. The sub-threshold swing S remains almost the same when the Lg larger than 80 nm. It increased rapidly when the Lg is scaled down to 50 nm due to the short channel effect SCE. However, the vertical device has a steady increase whereas the planar device has suffered immediate enhance of SCE. The analysis results confirmed that vertical MOSFET with double-gate structure is a potential solution to overcome SCE when scaled the channel length to 50nm and beyond.