METHODS: This was a single-center, retrospective study. Echocardiographic assessment of the LV geometry, mass, and free wall thickness was performed before stenting and before the arterial switch operation. Patients then underwent the arterial switch operation, and the postoperative outcomes were reviewed.
RESULTS: There were 11 consecutive patients (male, 81.8%; mean age at stenting, 43.11 ± 18.19 days) with TGA-IVS with involuted LV who underwent LV retraining by ductal stenting from July 2013 to December 2017. Retraining by ductus stenting failed in 4 patients (36.3%). Two patients required pulmonary artery banding, and another 2 had an LV mass index of less than 35 g/m2. Patients in the successful group had improved LV mass index from 45.14 ± 17.91 to 81.86 ± 33.11g/m2 (p = 0.023) compared with 34.50 ± 10.47 to 20.50 ± 9.88 g/m2 (p = 0.169) and improved LV geometry after ductal stenting. The failed group was associated with an increased need for extracorporeal support (14.5% vs 50%, p = 0.012). An atrial septal defect-to-interatrial septum length ratio of more than 0.38 was associated with failed LV retraining.
CONCLUSIONS: Ductal stenting is an effective method to retrain the involuted LV in TGA-IVS. A large atrial septal defect (atrial septal defect-to-interatrial septum length ratio >0.38) was associated with poor response to LV retraining.
OBJECTIVE: The purpose of this study was to sense atrial contractions from the Micra ACC signal and provide AV synchronous pacing.
METHODS: The Micra Accelerometer Sensor Sub-Study (MASS) and MASS2 early feasibility studies showed intracardiac accelerations related to atrial contraction can be measured via ACC in the Micra leadless pacemaker. The Micra Atrial TRacking Using A Ventricular AccELerometer (MARVEL) study was a prospective multicenter study designed to characterize the closed-loop performance of an AV synchronous algorithm downloaded into previously implanted Micra devices. Atrioventricular synchrony (AVS) was measured during 30 minutes of rest and during VVI pacing. AVS was defined as a P wave visible on surface ECG followed by a ventricular event <300 ms.
RESULTS: A total of 64 patients completed the MARVEL study procedure at 12 centers in 9 countries. Patients were implanted with a Micra for a median of 6.0 months (range 0-41.4). High-degree AV block was present in 33 patients, whereas 31 had predominantly intrinsic conduction during the study. Average AVS during AV algorithm pacing was 87.0% (95% confidence interval 81.8%-90.9%), 80.0% in high-degree block patients and 94.4% in patients with intrinsic conduction. AVS was significantly greater (P
METHODS: In 20 patients undergoing cardiac surgery in sevoflurane-remifentanil anesthesia, we analyzed intraoperative S' values which were determined after 10 min exposure to sevoflurane at 1.0, 2.0, and 3.0 inspired-vol% (T1, T2, and T3, respectively) with a fixed remifentanil dose (1.0 μg/kg/min) using transesophageal echocardiography.
RESULTS: Linear mixed-effect modeling demonstrated dose-dependent declines in S' according to the end-tidal sevoflurane concentration increments (C(ET)-sevoflurane, p < 0.001): the mean value of S' reduction for each 1.0 vol%-increment of C(ET)-sevoflurane was 1.7 cm/s (95 % confidence interval 1.4-2.1 cm/s). Medians of S' at T1, T2, and T3 (9.6, 8.9, and 7.5 cm/s, respectively) also exhibited significant declines (by 6.6, 15.6, and 21.2 % for T1 vs. T2, T2 vs. T3, and T1 vs. T3, p < 0.001, =0.002, and <0.001 in Friedman pairwise comparisons, respectively).
CONCLUSIONS: Administering sevoflurane as a part of a sevoflurane-remifentanil anesthesia regimen appears to dose-dependently reduce S', indicating LV systolic performance, in patients undergoing cardiac surgery. Further studies may be required to evaluate the clinical implications of these findings.
CASE PRESENTATION: A 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.
CONCLUSIONS: Point-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.
Case presentation: 50-year-old male had his chemoport inserted for adjuvant chemotherapy 3 years ago. During the removal, remaining half of the distal catheter was not found. There was no difficulties during the removal. Chest xray revealed that the fractured catheter had embolized to the right ventricle. Further history taking, he did experienced occasional palpitation and chest discomfort for the past six months. Electrocardiogram and cardiac enzymes were normal. Urgent removal of the fractured catheter via the percutaneous endovascular approach, under fluoroscopic guidance by an experience interventional radiologist was done. The procedure was successful without any complication. Patient made an uneventful recovery. He was discharged the following day, and was well during his 3rd month follow up.
Conclusion: Early detection and preventive measures can be done to prevent pinch-off syndrome. Unrecognized POS can result in fatal complications such as cardiac arrhythmia and septic embolization. Retrieval via the percutaneous endovascular approach provide excellent outcome in the case of embolized fractured catheter.