Displaying publications 41 - 60 of 69 in total

Abstract:
Sort:
  1. Teo PS, Nurul-Fadhilah A, Foo LH
    J Sci Med Sport, 2013 Jul;16(4):327-31.
    PMID: 22858164 DOI: 10.1016/j.jsams.2012.06.012
    To assess the validity and reproducibility of a new computer-based physical activity questionnaire (cPAQ) to estimate the habitual physical activity levels in Malaysian adolescents.
    Matched MeSH terms: Monitoring, Ambulatory
  2. Muhammad J, Jamial MM, Ishak A
    Korean J Fam Med, 2019 Sep;40(5):335-343.
    PMID: 30636386 DOI: 10.4082/kjfm.18.0026
    BACKGROUND: Home blood pressure monitoring is recommended to achieve controlled blood pressure. This study evaluated home blood pressure monitoring-improvement of office blood pressure control and treatment compliance among hypertensive patients.

    METHODS: A randomized controlled trial was conducted from December 2014 to April 2015. The home blood pressure monitoring group used an automatic blood pressure device along with standard hypertension outpatient care. Patients were seen at baseline and after 2 months. Medication adherence was measured using a novel validated Medication Adherence Scale (MAS) questionnaire. Office blood pressure and MAS were recorded at both visits. The primary outcomes included evaluation of mean office blood pressure and MAS within groups and between groups at baseline and after 2 months.

    RESULTS: Mean changes in systolic blood pressure (SBP) and diastolic blood pressure (DBP) and MAS differed significantly within groups. The home blood pressure monitoring group showed greater mean changes (SBP 17.6 mm Hg, DBP 9.5 mm Hg, MAS 1.5 vs. SBP 14.3 mm Hg, DBP 6.4 mm Hg, MAS 1.3), while between group comparisons showed no significant differences across all variables. The adjusted mean difference for mean SBP was 4.74 (95% confidence interval [CI], -0.65 to 10.13 mm Hg; P=0.084), mean DBP was 1.41 (95% CI, -2.01 to 4.82 mm Hg; P=0.415), and mean MAS was 0.05 (95% CI, -0.29 to 0.40 mm Hg; P=0.768).

    CONCLUSION: Short-term home blood pressure monitoring significantly reduced office blood pressure and improved medication adherence, albeit similarly to standard care.

    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  3. Beth, Mini Rani Mary, Shin, Yan Low, Poh, Yoke Chung
    MyJurnal
    Self-blood pressure monitoring (SBPM) at home creates greater awareness and patient participation in their treatment prevents hypertensive complications and helps facilitate doctors to make decisions on treatment. A study was conducted to assess the knowledge on self-blood pressure monitoring (SBPM) among hypertensive patients in selected wards of Hospital Lam Wah Ee, Malaysia. The results showed only 21 (32.3%) respondents monitored their blood pressure and 44 (67.7%) did not monitor their blood pressure at home. A total of 12 (18.4%) respondents reported that they monitored their blood pressure at home because they were aware of complications of hypertension. From those respondents who did not monitor blood pressure at home, only 13 (29.5%) respondents planned to carry out SBPM at home in the future. The overall knowledge score results for self-blood pressure monitoring showed that 6 (9.2%) subjects scored 8 and above, 42 (64.6%) scored 5-7, and 17 (26.1%) scored less than 4. The findings from the study will help the nurses understand the level of knowledge on SBPM among hypertensive patients, and include training and health education during hospitalisation reinforcing the importance and the technique of performing SBPM at home. It also helps to identify patients with poor control of blood pressure so that they can be referred to the physician for further treatment.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  4. Wang TD, Ohkubo T, Bunyi ML, Chadachan VM, Chia YC, Kario K, et al.
    Hypertens Res, 2023 Jul;46(7):1638-1649.
    PMID: 37041412 DOI: 10.1038/s41440-023-01259-1
    Uncontrolled hypertension is a significant problem in many parts of Asia. Effective management is essential to reduce the burden of hypertension. Home blood pressure monitoring (HBPM) is a promising tool that can aid in the diagnosis and management of hypertension. Experts from 11 countries/regions in Asia conceptualized a large-scale survey to examine the current realities of HBPM. A cross-sectional survey was conducted among health care professionals from China, India, Indonesia, Japan, Malaysia, the Philippines, Singapore, South Korea, Taiwan, Thailand, and Vietnam between November 2019 and June 2021. Physicians' responses were summarized using descriptive statistics. A total of 7945 physicians participated in the survey. Among all respondents, 50.3% and 33.5% viewed HBPM as highly recognized by physicians and patients in their country/region, respectively. Lack of understanding of HBPM and concern with the accuracy and reliability of HBPM devices were identified as key barriers to HBPM recognition. Nearly all physicians (95.9%) reported recommending HBPM to their patients; however, they reported less than 50% of their patients measured home blood pressure (HBP). Among physicians who recommended HBPM, only 22.4% and 54.1% cited HBP diagnostic threshold values and timing of taking antihypertensive drugs that were consistent with available guidelines, respectively. The survey reveals that the recognition of HBPM as a valuable tool to diagnose and manage hypertension is suboptimal in most parts of Asia. Despite high recommendation of HBPM to hypertensive patients by physicians, there are considerable discrepancies between guidelines recommendations and practice realities. The recognition of HBPM as a valuable tool for the diagnosis and management of hypertension is suboptimal among both physicians and patients in Asia. A clear and consistent guidance for proper HBPM practice and use of validated and calibrated HBP monitors are among the top priorities to support the integration of HBPM into daily patient care. HBPM: home blood pressure monitoring, HBP: home blood pressure.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  5. Kario K, Wang JG, Chia YC, Wang TD, Li Y, Siddique S, et al.
    J Clin Hypertens (Greenwich), 2022 Sep;24(9):1112-1120.
    PMID: 36196465 DOI: 10.1111/jch.14555
    Morning hypertension is an important clinical target in the management of hypertension for perfect 24-h blood pressure (BP) control. Morning hypertension is generally categorized into two types: "morning surge" type and "sustained nocturnal and morning hypertension" type. The "morning surge" type is characterized by an exaggerated morning blood pressure surge (MBPS), and the "sustained nocturnal and morning hypertension" type with continuous hypertension from nighttime to morning (non-dipper/riser type). They can be detected by home and ambulatory blood pressure measurements (HBPM and ABPM). These two forms of morning hypertension both increase the risk of cardiovascular and renal diseases, but may occur via different pathogenic mechanisms and are associated with different conditions. Morning hypertension should be treated to achieve a morning BP level of 
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  6. Su TT, Majid HA, Nahar AM, Azizan NA, Hairi FM, Thangiah N, et al.
    BMC Public Health, 2014;14 Suppl 3:S4.
    PMID: 25436830 DOI: 10.1186/1471-2458-14-S3-S4
    Death rates due to hypertension in low and middle income countries are higher compared to high income countries. The present study is designed to combine life style modification and home blood pressure monitoring for control of hypertension in the context of low and middle income countries.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/psychology*
  7. Goh CH, Ng SC, Kamaruzzaman SB, Chin AV, Tan MP
    Medicine (Baltimore), 2017 Oct;96(42):e8193.
    PMID: 29049203 DOI: 10.1097/MD.0000000000008193
    The aim of this study was to determine the relationship between falls and beat-to-beat blood pressure (BP) variability.Continuous noninvasive BP measurement is as accurate as invasive techniques. We evaluated beat-to-beat supine and standing BP variability (BPV) using time and frequency domain analysis from noninvasive continuous BP recordings.A total of 1218 older adults were selected. Continuous BP recordings obtained were analyzed to determine standard deviation (SD) and root mean square of real variability (RMSRV) for time domain BPV and fast-Fourier transform low frequency (LF), high frequency (HF), total power spectral density (PSD), and LF:HF ratio for frequency domain BPV.Comparisons were performed between 256 (21%) individuals with at least 1 fall in the past 12 months and nonfallers. Fallers were significantly older (P = .007), more likely to be female (P = .006), and required a longer time to complete the Timed-Up and Go test (TUG) and frailty walk test (P ≤ .001). Standing systolic BPV (SBPV) was significantly lower in fallers compared to nonfallers (SBPV-SD, P = .016; SBPV-RMSRV, P = .033; SBPV-LF, P = .003; SBPV-total PSD, P = .012). Nonfallers had significantly higher supine to standing ratio (SSR) for SBPV-SD, SBPV-RMSRV, and SBPV-total PSD (P = .017, P = .013, and P = .009). In multivariate analyses, standing BPV remained significantly lower in fallers compared to nonfallers after adjustment for age, sex, diabetes, frailty walk, and supine systolic BP. The reduction in frequency-domain SSR among fallers was attenuated by supine systolic BP, TUG, and frailty walk.In conclusion, reduced beat-to-beat BPV while standing is independently associated with increased risk of falls. Changes between supine and standing BPV are confounded by supine BP and walking speed.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/methods*
  8. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  9. Kario K, Tomitani N, Buranakitjaroen P, Chia YC, Park S, Chen CH, et al.
    J Clin Hypertens (Greenwich), 2018 12;20(12):1686-1695.
    PMID: 30444315 DOI: 10.1111/jch.13415
    A self-measured home blood pressure (BP)-guided strategy is an effective practical approach to hypertension management. The Asia BP@Home study is the first designed to investigate current home BP control status in different Asian countries/regions using standardized home BP measurements taken with the same validated home BP monitoring device with data memory. We enrolled 1443 medicated hypertensive patients from 15 Asian specialist centers in 11 countries/regions between April 2017 and March 2018. BP was relatively well controlled in 68.2% of patients using a morning home systolic BP (SBP) cutoff of <135 mm Hg, and in 55.1% of patients using a clinic SBP cutoff of <140 mm Hg. When cutoff values were changed to the 2017 AHA/ACC threshold (SBP <130 mm Hg), 53.6% of patients were well controlled for morning home SBP. Using clinic 140 mm Hg and morning home 135 mm Hg SBP thresholds, the proportion of patients with well-controlled hypertension (46%) was higher than for uncontrolled sustained (22%), white-coat (23%), and masked uncontrolled (9%) hypertension, with significant country/regional differences. Home BP variability in Asian countries was high, and varied by country/region. In conclusion, the Asia BP@Home study demonstrated that home BP is relatively well controlled at hypertension specialist centers in Asia. However, almost half of patients remain uncontrolled for morning BP according to new guidelines, with significant country/regional differences. Strict home BP control should be beneficial in Asian populations. The findings of this study are important to facilitate development of health policies focused on reducing cardiovascular complications in Asia.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/instrumentation; Blood Pressure Monitoring, Ambulatory/methods*
  10. Ahmad N, Hassan Y, Tangiisuran B, Meng OL, Abd Aziz N, Ahmad FU, et al.
    J Eval Clin Pract, 2013 Oct;19(5):798-804.
    PMID: 22583820 DOI: 10.1111/j.1365-2753.2012.01852.x
    RATIONALE, AIMS AND OBJECTIVES: Existing literature suggests that doctors' poor adherence with guidelines is one of the major contributing factors to suboptimal control of hypertension. This study aims to evaluate doctors' adherence with Malaysian clinical practice guideline (CPG 2008) in a tertiary care hospital, and factors associated with guideline adherence and hypertension control.
    METHODS: This was a cross-sectional study conducted at Hospital Pulau Pinang, Penang, Malaysia. Prescriptions written by 26 enrolled doctors to 650 established hypertensive outpatients (25 prescriptions per enrolled doctor) were noted on visit 1 along with patients' demographic and clinical data. The noted prescriptions were classified either as compliant or non-compliant to CPG (2008). Five hundred twenty (80%) of the enrolled patients (20 patients per enrolled doctor) were followed for one more visit. Blood pressure (BP) noted on visit 2 was related to the prescription written on visit 1. SPSS 16 (SPSS Inc., Chicago, IL, USA) was used for data analysis.
    RESULTS: Three hundred forty-nine (67.1%) patients received guidelines compliant pharmacotherapy. In multivariate analysis, hypertension clinic had significant negative association with guidelines adherence. Two hundred sixty-five patients (51%) were at goal BP on visit 2. In multivariate analysis, angiotensin-converting enzyme inhibitors and guidelines adherence had significant positive, while renal disease, diabetes mellitus and diabetic clinic had significant negative association with hypertension control.
    CONCLUSIONS: An overall fair level of adherence with guidelines and better control of hypertension was observed. Guidelines compliant practices resulted in better control of hypertension. The gaps between what guidelines recommend and clinical practice were especially seen in the pharmacotherapy of uncomplicated hypertension and hypertension with diabetes mellitus and renal disease.
    KEYWORDS: Malaysia; adherence; guidelines; hypertension
    Study site: Cardiology, nephrology, diabetic and hypertension clinics, Hospital Pulau Pinang, Malaysia
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/statistics & numerical data
  11. Zhang ZY, Yang WY, Dominiczak AF, Wang JG, Wu Y, Almustafa B, et al.
    Hypertension, 2019 11;74(5):1064-1067.
    PMID: 31422692 DOI: 10.1161/HYPERTENSIONAHA.119.13206
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/methods*
  12. Kario K, Shin J, Chen CH, Buranakitjaroen P, Chia YC, Divinagracia R, et al.
    J Clin Hypertens (Greenwich), 2019 Sep;21(9):1250-1283.
    PMID: 31532913 DOI: 10.1111/jch.13652
    Hypertension is an important public health issue because of its association with a number of significant diseases and adverse outcomes. However, there are important ethnic differences in the pathogenesis and cardio-/cerebrovascular consequences of hypertension. Given the large populations and rapidly aging demographic in Asian regions, optimal strategies to diagnose and manage hypertension are of high importance. Ambulatory blood pressure monitoring (ABPM) is an important out-of-office blood pressure (BP) measurement tool that should play a central role in hypertension detection and management. The use of ABPM is particularly important in Asia due to the specific features of hypertension in Asian patients, including a high prevalence of masked hypertension, disrupted BP variability with marked morning BP surge, and nocturnal hypertension. This HOPE Asia Network document summarizes region-specific literature on the relationship between ABPM parameters and cardiovascular risk and target organ damage, providing a rationale for consensus-based recommendations on the use of ABPM in Asia. The aim of these recommendations is to guide and improve clinical practice to facilitate optimal BP monitoring with the goal of optimizing patient management and expediting the efficient allocation of treatment and health care resources. This should contribute to the HOPE Asia Network mission of improving the management of hypertension and organ protection toward achieving "zero" cardiovascular events in Asia.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/methods*
  13. Tong SF, Aziz NA, Chin GL
    Med J Malaysia, 2007 Dec;62(5):390-3.
    PMID: 18705473 MyJurnal
    Thrombocytopaenia is often relied upon as an important criterion for the diagnosis of dengue infection among patients presenting with an acute non-specific febrile illness. This study was aimed to assess usefulness of thrombocytopaenia in the diagnosis of acute dengue virus infection. This was a clinic based prospective cohort study from May to November 2003. Consecutive patients presenting with acute non-specific febrile illness of less than two weeks were selected from two urban primary care centres. We did full blood count examination (FBC) on the day of visit and dengue serology on day five of illness for all patients enrolled. We repeated the FBC examination for patients who had initial normal platelet counts. Thrombocytopaenia was defined as platelet count < 150 X 10(9)/L. Eighty-seven patients enrolled in the study. Complete data was available for 73 patients. The prevalence of acute dengue virus infection was 27.6%. The sensitivity and specificity were 88% and 71% respectively. The likelihood of acute dengue infection in the presence of thrombocytopaenia was 2.52 and likelihood of not having dengue infection in normal platelet count patients was 5.22. Thrombocytopaenia has fair predictive value in diagnosing acute dengue virus infection. It was more useful to exclude than to diagnose dengue infection.

    Study site: Primary Care Centre of Hospital Universiti
    Kebangsaan Malaysia (HUKM) and Batu 9 Health Clinic Hulu Langat,
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  14. Rafidah HM, Azizi A, Noriah MN
    Med J Malaysia, 2006 Jun;61(2):189-98.
    PMID: 16898310 MyJurnal
    Apart from the mean 24 hour ambulatory blood pressure (ABP), the blood pressure variability (BPV) also bears an independent relationship with target-organ damage in hypertension. A reduction in arterial compliance has been demonstrated in hypertension but its relation to BPV is still unknown. The aim of the study is to compare BPV and arterial compliance between hypertensive and normotensive subjects. Eighteen hypertensives and 18 controls were enrolled. Noninvasive 24-hour ABP monitoring was performed with BR-102 monitor (Schiller Inc. Germany). Arterial compliance was determined by the HDI/Pulsewave Research Cardiovascular Profiling Instrument (Hypertension Diagnostic Inc. USA). There were significantly higher systolic, diastolic and mean arterial BPV in hypertensives as compared to normotensive group. Only systolic BPV remained significantly high in hypertensives during night time. There were lower arterial compliances in hypertensive as compared to normotensive group. No significant relationship however was found between BPV and arterial compliance in hypertensive subjects. In conclusion, there were higher BPV and lower arterial compliances in hypertensive subjects as compared to normotensive subjects.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  15. Yeo CK, Hapizah MN, Khalid BAK, Wan Nazainimoon WM, Khalid Y
    Med J Malaysia, 2004 Jun;59(2):185-9.
    PMID: 15559168
    Diabetes mellitus is an important coronary artery disease risk factor. The presence of microalbuminuria, which indicates renal involvement in diabetic patients, is associated with an increased cardiovascular risk. There are suggestions that diabetic patients with microalbuminuria have more adverse risk profile such as higher ambulatory blood pressure and total cholesterol levels to account for the increased cardiovascular morbidity and mortality. QT dispersion is increasingly being recognized as a prognostic factor for coronary artery disease and sudden death. Some studies have suggested that QT dispersion is an important predictor of mortality in Type II diabetic patients. Our cross sectional study was to compare the QT dispersion and 24 hour ambulatory blood pressure monitoring between diabetic patients with microalbuminuria and those without microalbuminuria. Diabetic patients with overt coronary artery disease were excluded from the study. A total of 108 patients were recruited of which 57 patients had microalbuminuria and 51 were without microalbuminuria. The mean value of QT dispersion was significantly higher in patients with microalbuminuria than in patients without microalbuminuria (58.9 +/- 27.9 ms vs. 47.1 +/- 25.0 ms, p < 0.05). The mean 24 hour systolic and diastolic blood pressures were significantly higher in patients with microalbuminuria than in patients without microalbuminuria (129.5 +/- 12.3 mm Hg vs 122.3 +/- 10.2 mm Hg, p < 0.05 and 78.4 +/- 6.9 mm Hg vs 75.3 +/- 6.8 mm Hg, p < 0.05, respectively). Our study suggests that QT dispersion prolongation, related perhaps to some autonomic dysfunction, is an early manifestation of cardiovascular aberration in diabetic patients with microalbuminuria. The higher blood pressure levels recorded during a 24-hour period min diabetics with microalbuminuria could also possibly account for the worse cardiovascular outcome in this group of patients.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  16. Yusoff K, Razak TA, Yusof N, Rafee NM
    Int J Clin Pract, 1999 Jun;53(4):277-80.
    PMID: 10563072
    ACE inhibitors are important therapeutic agents in controlling hypertension, correcting some of its pathophysiological derangement and improving its prognosis. While there are many such agents, there may be some important differences between them. This placebo run-in, double blind, crossover study, using 24-hour ambulatory blood pressure monitoring, compares the efficacy of perindopril 4-8 mg and enalapril 10-20 mg as once daily antihypertensive agents on 32 patients. For diastolic blood pressure (DBP), perindopril had a placebo-corrected peak (P) reduction of blood pressure (BP) of -6.4 +/- 1.3 mmHg vs its placebo-corrected trough (T) of -5.2 +/- 1.7 mmHg. Enalapril had a reduction in DBP of -8.5 +/- 1.3 mmHg (P) and -5.7 +/- 1.7 mmHg (T). For systolic blood pressure (SBP), perindopril had a reduction of -7.5 +/- 1.6 mmHg (P) vs -7.3 +/- 2.2 mmHg (T) compared to enalapril with -10.8 +/- 1.6 mmHg (P) vs -8.3 +/- 2.3 mmHg (T). Placebo-corrected trough-to-peak ratio (SBP/DBP) for perindopril was 0.97/0.81 vs 0.77/0.67 for enalapril. There was no difference noted in 24-hour mean BP, area under the curve or post-dose casual BP measurements. Both perindopril and enalapril were well tolerated and the two treatment groups had similar safety profiles. Perindopril thus had a predictable and sustained blood pressure effect giving a 24-hour cover for the patient without excessive peak effect or poor trough effect.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  17. Azizan NA, Majid HA, Nahar Mohamed A, Su TT
    SAGE Open Med, 2020;8:2050312120960563.
    PMID: 33014371 DOI: 10.1177/2050312120960563
    Objective: To ascertain the effect of dietary practice modification and a peer-support home blood pressure monitoring program on the nutritional intake (macronutrients and micronutrients), blood pressure and biochemical profiles of hypertension patients in a low-income community setting.

    Methods: This is a pre- and post-measurement intervention study conducted in low-income community housing projects in Kuala Lumpur, Malaysia. A total of 90 participants aged 18 years and above with hypertension received intervention. The participants were divided into small groups and received instructions on the use of home blood pressure measurement. They also attended a series of talks on dietary intake modification and exercise demonstration for the first six months (active phase). In another 6 months (maintenance phase), they received only pamphlet and SMS reminders. Their anthropometry, blood pressure, dietary, and biochemical parameter changes were measured at baseline, 6 months, and 12 months of intervention.

    Results: Macronutrients and micronutrients showed a significant improvement at the end of 12-month dietary intervention. The energy, carbohydrate, protein, total fat, sodium, and potassium are showing significant reduction from baseline to end of the 12-month intervention. There is no significant reduction in blood pressure. Fasting blood glucose, renal sodium, triglyceride, low-density lipoprotein cholesterol and high-density lipoprotein cholesterol showed a significant improvement, after controlling for age and reported physical activity.

    Conclusion: The intervention improved the nutritional intake and biochemical profiles of the low-income urban population with hypertension. This promising result should be replicated in a larger scale study.

    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  18. Siti Suhaila MY, Juwita S, Harmy MY, Tengku Alina TI
    MyJurnal
    Introduction: Ambulatory blood pressure accurately reflects a patient's actual blood pressure than casual or office blood pressure. This study aims to describe the circadian blood pressure profile of hypertensive patients and to identify the associated cardiovascular risk factors in non-dippers.
    Methods: A cross-sectional study was conducted from 1st January 2008 to 30th June 2008 among hypertensive patients attending Family Medicine Clinic HUSM. Schiller BR-102 plus was used to get 24 hours blood pressure (BP) reading. Mean of two offices BP were also taken. Non-dippers are defined as a systolic or diastolic nocturnal drop of less than 10%. Analysis was done using SPSS Version 12.
    Results: 105 patients were recruited with mean (SD) age of 51.8 (9.34) year old. The mean (SD) 24-hour systolic and diastolic BP was 128.4 (12.7) mmHg and 79.7 (8.74) mmHg respectively. Mean (SD) daytime systolic and diastolic BP was 132.1 (11.72) mmHg and 82.4 (9.41) mmHg while for the night time were 123.3 (12.78) mmHg and 76.2 (9.01) mmHg. Mean (SD) systolic and diastolic office BP was 144.2(15.16) mmHg and 90.2(9.71) mmHg. Percentage of non dippers were 68.6% for systolic and 61.9% for diastolic.
    Conclusion: Mean 24 hours and daytime ambulatory BP was normal but the mean night time diastolic and office BP was above-normal value. Majority of the patients were categorized as non dippers. Therefore, using ambulatory BP is clinically important to get a better understanding of blood pressure fluctuations over 24-hour periods compared to simple clinical measurements.
    Study site: Family Medicine Clinic, Hospital Universiti Sains Malysia (HUSM), Kelantan, Malaysia
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  19. Nakai M, Ribeiro RV, Stevens BR, Gill P, Muralitharan RR, Yiallourou S, et al.
    Hypertension, 2021 09;78(3):804-815.
    PMID: 34333988 DOI: 10.1161/HYPERTENSIONAHA.121.17288
    [Figure: see text].
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
  20. Mahfoud F, Mancia G, Schmieder RE, Ruilope L, Narkiewicz K, Schlaich M, et al.
    J Am Coll Cardiol, 2022 Nov 15;80(20):1871-1880.
    PMID: 36357087 DOI: 10.1016/j.jacc.2022.08.802
    BACKGROUND: Renal denervation (RDN) has been shown to lower blood pressure (BP), but its effects on cardiovascular events have only been preliminarily evaluated. Time in therapeutic range (TTR) of BP is associated with cardiovascular events.

    OBJECTIVES: This study sought to assess the impact of catheter-based RDN on TTR and its association with cardiovascular outcomes in the GSR (Global SYMPLICITY Registry).

    METHODS: Patients with uncontrolled hypertension were enrolled and treated with radiofrequency RDN. Office and ambulatory systolic blood pressure (OSBP and ASBP) were measured at 3, 6, 12, 24, and 36 months postprocedure and used to derive TTR. TTR through 6 months was assessed as a predictor of cardiovascular events from 6 to 36 months using a Cox proportional hazard regression model.

    RESULTS: As of March 1, 2022, 3,077 patients were enrolled: 42.2% were female; mean age was 60.5 ± 12.2 years; baseline OSBP was 165.6 ± 24.8 mm Hg; and baseline ASBP was 154.3 ± 18.7 mm Hg. Patients were prescribed 4.9 ± 1.7 antihypertensive medications at baseline and 4.8 ± 1.9 at 36 months. At 36 months, mean changes were -16.7 ± 28.4 and -9.0 ± 20.2 mm Hg for OSBP and ASBP, respectively. TTR through 6 months was 30.6%. A 10% increase in TTR after RDN through 6 months was associated with significant risk reductions from 6 to 36 months of 15% for major adverse cardiovascular events (P < 0.001), 11% cardiovascular death (P = 0.010), 15% myocardial infarction (P = 0.023), and 23% stroke (P < 0.001).

    CONCLUSIONS: There were sustained BP reductions and higher TTR through 36 months after RDN. A 10% increase in TTR through 6 months was associated with significant risk reductions in major cardiovascular events from 6 to 36 months. (Global SYMPLICITY Registry [GSR] DEFINE; NCT01534299).

    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links