Displaying publications 21 - 40 of 84 in total

Abstract:
Sort:
  1. Chowdhury RH, Reaz MB, Ali MA, Bakar AA, Chellappan K, Chang TG
    Sensors (Basel), 2013;13(9):12431-66.
    PMID: 24048337 DOI: 10.3390/s130912431
    Electromyography (EMG) signals are becoming increasingly important in many applications, including clinical/biomedical, prosthesis or rehabilitation devices, human machine interactions, and more. However, noisy EMG signals are the major hurdles to be overcome in order to achieve improved performance in the above applications. Detection, processing and classification analysis in electromyography (EMG) is very desirable because it allows a more standardized and precise evaluation of the neurophysiological, rehabitational and assistive technological findings. This paper reviews two prominent areas; first: the pre-processing method for eliminating possible artifacts via appropriate preparation at the time of recording EMG signals, and second: a brief explanation of the different methods for processing and classifying EMG signals. This study then compares the numerous methods of analyzing EMG signals, in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above.
    Matched MeSH terms: Muscle Contraction/physiology*
  2. Ajit Singh DK, Bailey M, Lee R
    Muscle Nerve, 2011 Jul;44(1):74-9.
    PMID: 21488056 DOI: 10.1002/mus.21998
    Loss of lumbar extensor muscle strength and fatigue resistance may contribute to functional disability.
    Matched MeSH terms: Muscle Contraction/physiology
  3. Amalourde A, Vinayaga P, Naveed N, Choon SK, Zaleha O
    Med J Malaysia, 2004 Dec;59 Suppl F:8-13.
    PMID: 15941154
    In our centre the non-availability computerized exercise machines limits the objective monitoring of strength rehabilitation. We undertook this research programme to objectively measure triceps muscle strength by interfacing NORSK-Gym machine with accelerometer and positional transducers to a computer. This data was tabulated and processed using Microsoft Excel. The positional transducer was first calibrated and it showed an excellent Pearson Correlation Coefficients against a standard metric reading (r = 0.9999). Peak Force was used as a test parameter for isotonic triceps muscle strength measurements. The criterion-referenced validity was established as the peak forces measured using the accelerometer and positional transducer demonstrated identical Peak Forces (r = 0.94). Analysis of our mean Peak Force measurements using non-biological force as well as the intra-individual reproducibility demonstrated excellent Pearson Correlation Coefficients (r) = 0.982-0.998 and 0.929-0.972 respectively. This computerized adaptation of the NORSK-Gym machine produced an objective, valid and reproducible triceps muscle strength measurement.
    Matched MeSH terms: Muscle Contraction/physiology*
  4. Harba MI, Teng LY
    Front Med Biol Eng, 1999;9(1):31-47.
    PMID: 10354908
    Cross-correlating two surface EMG signals detected at two different locations along the path of flow of action potential enables the measurement of the muscle fiber average conduction velocity in those active motor units monitored by the electrodes. The position of the peak of the cross-correlation function is the time delay between the two signals and hence the velocity may be deduced. The estimated velocity using this technique has been observed previously to depend on the location of the electrodes on the muscle surface. Different locations produced different estimates. In this paper we present a measurement system, analyze its inherent inaccuracies and use it for the purpose of investigating the reliability of measurement of conduction velocity from surface EMG. This system utilizes EMG signals detected at a number of locations on the biceps brachii, when under light tension, to look for any pattern of variations of velocity as a function of location and time. It consists of a multi-electrode unit and a set of eight parallel on-line correlators. The electrode unit and the parallel correlators ensure that these measurements are carried out under the same physical and physiological conditions of the muscle. Further, the same detected signals are used in different measurement configurations to try to understand the reasons behind the observed variations in the estimated velocity. The results obtained seem to suggest that there will always be an unpredictable random component superimposed on the estimated velocity, giving rise to differences between estimates at different locations and differences in estimates with time at the same location. Many factors contribute to this random component, such as the non-homogeneous medium between the muscle fibers and the electrodes, the non-parallel geometry and non-uniform conduction velocity of the fibers, and the physical and physiological conditions of the muscle. While it is not possible to remove this random component completely from the measurement, the user must be aware of its presence and how to reduce its effects.
    Matched MeSH terms: Muscle Contraction/physiology
  5. Nabishah BM, Morat PB, Alias AK, Kadir BA, Khalid BA
    Clin Exp Pharmacol Physiol, 1992 Dec;19(12):839-42.
    PMID: 1335381
    1. Male Sprague-Dawley rats were made either hyper- or hypothyroid with thyroxine or 4-methyl-2-thiouracil, respectively. Bronchial smooth muscle (BSM) contractility and lung cyclic adenosine 3',5'-monophosphate (cAMP) content were measured in both conditions. 2. Bronchial smooth muscle contractility was significantly weaker in hyperthyroid rats, while the BSM contractility of hypothyroid rats was the same as controls. 3. The cAMP content of hyperthyroid rat lungs was similar to controls but was decreased in hypothyroid rats. 4. These studies demonstrated that both the hyper- and hypothyroid states affect respiration, although the mechanisms involved with different for each condition.
    Matched MeSH terms: Muscle Contraction/physiology
  6. Talib I, Sundaraj K, Lam CK
    Sci Rep, 2019 11 07;9(1):16166.
    PMID: 31700129 DOI: 10.1038/s41598-019-52536-4
    This study aimed to quantify the association of four anthropometric parameters of the human arm, namely, the arm circumference (CA), arm length (LA), skinfold thickness (ST) and inter-sensor distance (ISD), with amplitude (RMS) and crosstalk (CT) of mechanomyography (MMG) signals. Twenty-five young, healthy, male participants were recruited to perform forearm flexion, pronation and supination torque tasks. Three accelerometers were employed to record the MMG signals from the biceps brachii (BB), brachialis (BRA) and brachioradialis (BRD) at 80% maximal voluntary contraction (MVC). Signal RMS was used to quantify the amplitude of the MMG signals from a muscle, and cross-correlation coefficients were used to quantify the magnitude of the CT among muscle pairs (BB & BRA, BRA & BRD, and BB & BRD). For all investigated muscles and pairs, RMS and CT showed negligible to low negative correlations with CA, LA and ISD (r = -0.0001--0.4611), and negligible to moderate positive correlations with ST (r = 0.004-0.511). However, almost all of these correlations were statistically insignificant (p > 0.05). These findings suggest that RMS and CT values for the elbow flexor muscles recorded and quantified using accelerometers appear invariant to anthropometric parameters.
    Matched MeSH terms: Muscle Contraction/physiology*
  7. Naeem J, Hamzaid NA, Islam MA, Azman AW, Bijak M
    Med Biol Eng Comput, 2019 Jun;57(6):1199-1211.
    PMID: 30687901 DOI: 10.1007/s11517-019-01949-4
    Patients with spinal cord injury (SCI) benefit from muscle training with functional electrical stimulation (FES). For safety reasons and to optimize training outcome, the fatigue state of the target muscle must be monitored. Detection of muscle fatigue from mel frequency cepstral coefficient (MFCC) feature of mechanomyographic (MMG) signal using support vector machine (SVM) classifier is a promising new approach. Five individuals with SCI performed FES cycling exercises for 30 min. MMG signals were recorded on the quadriceps muscle group (rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM)) and categorized into non-fatigued and fatigued muscle contractions for the first and last 10 min of the cycling session. For each subject, a total of 1800 contraction-related MMG signals were used to train the SVM classifier and another 300 signals were used for testing. The average classification accuracy (4-fold) of non-fatigued and fatigued state was 90.7% using MFCC feature, 74.5% using root mean square (RMS), and 88.8% with combined MFCC and RMS features. Inter-subject prediction accuracy suggested training and testing data to be based on a particular subject or large collection of subjects to improve fatigue prediction capacity. Graphical abstract ᅟ.
    Matched MeSH terms: Muscle Contraction/physiology
  8. Duangjai A, Parseatsook K, Sajjapong W, Saokaew S
    J Med Food, 2020 Nov;23(11):1169-1175.
    PMID: 32976072 DOI: 10.1089/jmf.2020.4769
    Vietnamese coriander (Polygonum odoratum Lour.) is a plant native to northern Thailand. The biological activities of P. odoratum Lour. extract (POE) include antibacterial, antiviral, and expectorant. However, the effect of POE on intestinal smooth muscle motility is unclear. The aim of this study was to evaluate the relaxant effects of POE on isolated rat ileum. Propranolol (1 μM), calcium chloride (1-20 mM), and Nω-nitro-l-arginine methylester (l-NAME, 100 μM) were used to investigate the mechanisms of action. The results showed that POE (0.01-5 mg/mL) reduced KCl-induced contraction. In addition, POE (1 mg/mL) reduced the contraction by propranolol and l-NAME and attenuated CaCl2-induced contractions. Our results indicate that the relaxation effect of POE on ileum contractions seems to involve nitric oxide and β-adrenergic pathways, and blockade of calcium influx. These findings provide a pharmacological basis for the traditional use of POE to treat gastrointestinal disorders such as irritable bowel syndrome or diarrhea.
    Matched MeSH terms: Muscle Contraction/drug effects*
  9. Achike FI, Kwan CY
    Acta Pharmacol Sin, 2002 Aug;23(8):698-704.
    PMID: 12147191
    In an attempt to pharmacologically characterize the Chinese antihypertensive drug, tetrandrine, we observed in rat-tail arteries, an unusual contraction in tissues that were stimulated with high [KCl] and not those stimulated with phenylephrine. The characteristics of this contraction were studied.
    Matched MeSH terms: Muscle Contraction/drug effects*
  10. Loh PY, Hayashi K, Nasir N, Muraki S
    J Mot Behav, 2020;52(5):634-642.
    PMID: 31571525 DOI: 10.1080/00222895.2019.1670128
    This study investigated the muscle activity and force variability in response to perturbation of assistive force during isometric elbow flexion. Sixteen healthy right-handed young men (age: 22.0 ± 1.1 years; height: 171.9 ± 4.8 cm; weight 68.4 ± 11.2 kg) were recruited and the muscle activity of biceps brachii and triceps brachii were assessed using surface electromyography. Workload force and assistive force applied on isometric elbow flexion significantly affected the changes in both biceps and triceps muscle activities. A higher assistive force was shown to result in reduced biceps muscle activity compared to the unassisted period. In contrast, the efficiency of the assistive force acting on the biceps decreased as the assistive force increased. In general, the force variability of the biceps muscle remained approximately the same at lower workload force conditions than that at higher workload force conditions. In conclusion, higher assistive force may not yield a higher performance efficiency in human-assistive force interaction.
    Matched MeSH terms: Muscle Contraction/physiology
  11. Chetty N, Du A, Hodgson WC, Winkel K, Fry BG
    Toxicon, 2004 Aug;44(2):193-200.
    PMID: 15246769
    We examined the neurotoxicity of the following sea snake venoms: Enhydrina schistosa (geographical variants from Weipa and Malaysia), Lapemis curtus (Weipa and Malaysia), Laticauda colubrina, Aipysurus laevis, Aipysurus fuscus and Aipysurus foliosquamatus. Venom from a terrestrial snake, Notechis scutatus (tiger snake), was used as a reference. All venoms (1 and 3 microg/ml) abolished indirect twitches of the chick biventer cervicis muscle and significantly inhibited responses to ACh (1 mM) and CCh (20 microM), but not KCl (40 mM), indicating the presence of post-synaptic toxins. Prior administration (10 min) of CSL sea snake antivenom (1 unit/ml) attenuated the twitch blockade produced by N. scutatus venom and all sea snake venoms (1 microg/ml). Prior administration (10 min) of CSL tiger snake antivenom (1 unit/ml) attenuated the twitch blockade of all venoms except those produced by E. schistosa (Malaysia and Weipa) and A. foliosquamatus. Administration of CSL sea snake antivenom (1 unit/ml) at t90 (i.e. time at which 90% inhibition of initial twitch height occurred) reversed the inhibition of twitches (20-50%) produced by the sea snake venoms (1 microg/ml) but not by N. scutatus venom (1 microg/ml). CSL tiger snake antivenom (1 unit/ml) administered at t90 produced only minor reversal (i.e. 15-25%) of the twitch blockade caused by L. curtus (Weipa), A. foliosquamatus, L. colubrina and A. laevis venoms (1 microg/ml). Differences in the rate of reversal of the neurotoxicity produced by the two geographical variants of E. schistosa venom, after addition of CSL sea snake antivenom, indicate possible differences in venom components. This study shows that sea snake venoms contain potent post-synaptic activity that, despite the significant genetic distances between the lineages, can be neutralised with CSL sea snake antivenom. However, the effects of CSL tiger snake antivenom are more variable.
    Matched MeSH terms: Muscle Contraction/drug effects*
  12. Hébert-Losier K, Yin NS, Beaven CM, Tee CCL, Richards J
    J Electromyogr Kinesiol, 2019 Feb;44:36-45.
    PMID: 30496944 DOI: 10.1016/j.jelekin.2018.11.009
    Kinesiology-type tape (KTT) has become popular in sports for injury prevention, rehabilitation, and performance enhancement. Many cyclists use patella KTT; however, its benefits remain unclear, especially in uninjured elite cyclists. We used an integrated approach to investigate acute physiological, kinematic, and electromyographic responses to patella KTT in twelve national-level male cyclists. Cyclists completed four, 4-minute submaximal efforts on an ergometer at 100 and 200 W with and without patella KTT. Economy, energy cost, oxygen cost, heart rate, efficiency, 3D kinematics, and lower-body electromyography signals were collected over the last minute of each effort. Comfort levels and perceived change in knee stability and performance with KTT were recorded. The effects of KTT were either unclear, non-significant, or clearly trivial on all collected physiological and kinematic measures. KTT significantly, clearly, and meaningfully enhanced vastus medialis peak, mean, and integrated electromyographic signals, and vastus medialis-to-lateralis activation. Electromyographic measures from biceps femoris and biceps-to-rectus femoris activation ratio decreased in either a significant or clinically meaningful manner. Despite most cyclists perceiving KTT as comfortable, increasing stability, and improving performance, the intervention exerted no considerable effects on all physiological and kinematic measures. KTT did alter neuromuscular recruitment, which has potential implications for injury prevention.
    Matched MeSH terms: Muscle Contraction*
  13. Nazmi N, Abdul Rahman MA, Yamamoto S, Ahmad SA, Zamzuri H, Mazlan SA
    Sensors (Basel), 2016 Aug 17;16(8).
    PMID: 27548165 DOI: 10.3390/s16081304
    In recent years, there has been major interest in the exposure to physical therapy during rehabilitation. Several publications have demonstrated its usefulness in clinical/medical and human machine interface (HMI) applications. An automated system will guide the user to perform the training during rehabilitation independently. Advances in engineering have extended electromyography (EMG) beyond the traditional diagnostic applications to also include applications in diverse areas such as movement analysis. This paper gives an overview of the numerous methods available to recognize motion patterns of EMG signals for both isotonic and isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who would like to select the most appropriate methodology in classifying motion patterns, especially during different types of contractions. For feature extraction, the probability density function (PDF) of EMG signals will be the main interest of this study. Following that, a brief explanation of the different methods for pre-processing, feature extraction and classifying EMG signals will be compared in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above.
    Matched MeSH terms: Muscle Contraction/physiology
  14. Rusmili MR, Tee TY, Mustafa MR, Othman I, Hodgson WC
    Biochem Pharmacol, 2014 Mar 15;88(2):229-36.
    PMID: 24440452 DOI: 10.1016/j.bcp.2014.01.004
    Bungarus fasciatus is one of three species of krait found in Malaysia. Envenoming by B. fasciatus results in neurotoxicity due to the presence of presynaptic and postsynaptic neurotoxins. Antivenom, either monovalent or polyvalent, is the treatment of choice in systemically envenomed patients. In this study, we have isolated a postsynaptic neurotoxin which we named α-elapitoxin-Bf1b. This toxin has an approximate molecular weight of 6.9 kDa, with LCMS/MS data showing that it is highly homologous with Neurotoxin 3FTx-RI, a toxin identified in the Bungarus fasciatus venom gland transcriptome. α-Elapitoxin-Bf1b also shared similarity with short-chain neurotoxins from Laticauda colubrina and Pseudechis australis. α-Elapitoxin-Bf1b produced concentration- and time-dependent neurotoxicity in the indirectly-stimulated chick biventer cervicis muscle preparation, an effect partially reversible by repetitive washing of the preparation. The pA2 value for α-elapitoxin-Bf1b of 9.17 ± 0.64, determined by examining the effects of the toxin on cumulative carbacol concentration-response curves, indicated that the toxin is more potent than tubocurarine and α-bungarotoxin. Pre-incubation of Bungarus fasciatus monovalent and neuro polyvalent antivenom failed to prevent the neurotoxic effects of α-elapitoxin-Bf1b in the chick biventer cervicis muscle preparation. In conclusion, the isolation of a postsynaptic neurotoxin that cannot be neutralized by either monovalent and polyvalent antivenoms may indicate the presence of isoforms of postsynaptic neurotoxins in Malaysian B. fasciatus venom.
    Matched MeSH terms: Muscle Contraction/drug effects; Muscle Contraction/physiology
  15. Abdul Rahim MF, Shaharudin S
    J Taibah Univ Med Sci, 2018 Dec;13(6):572-575.
    PMID: 31435380 DOI: 10.1016/j.jtumed.2018.08.001
    Objectives: This study aimed to determine isokinetic profiles of rotator cuff muscle strength and power in adolescent state-level weightlifters.

    Methods: Nineteen young state-level weightlifters performed concentric strength tests of the upper limbs using an isokinetic dynamometer. Peak torque/body weight was measured for each weightlifter in dominant and non-dominant limbs.

    Results: Peak torque/body weight was significantly different in external rotation (p  0.05). Time to peak torque in external rotation was less in the dominant than in the non-dominant limb. However, opposite results were obtained in external rotation, whereby time to peak torque was longer in the dominant limb compared to the non-dominant limb. Similarly, no significant difference was found between dominant and non-dominant limbs in terms of average power (p > 0.05).

    Conclusions: The findings of this study may help in establishing potential imbalance in variables of muscular contractions between dominant and non-dominant limbs of weightlifters. This may help to maximise performance and minimise potential shoulder injury.

    Matched MeSH terms: Muscle Contraction
  16. Hani Hafeeza Halim, Mohd Sabri Pak Dek, Azizah Abdul Hamid, Ahmad Haniff Jaafar
    MyJurnal
    Among athletes, endurance is one of the key elements to victory. In addition to
    training, athletes normally used supplement to prevent fatigue during the event. With
    prolonged and intense activity, our body started to experience decrease in muscle
    performance due to several factors such as oxidative stress, dehydration and
    accumulation of lactic acid in the body fluids. The free radicals generated during
    intense exercise will expose the cells to oxidative damages. In the event of
    dehydration, there will be significant losses of water and functional electrolytes during
    intense exercise which affected the body fluid balance. Fatigue will also occur during
    reduced oxygen in aerobic metabolism which later caused accumulation of lactic acid
    in the muscle. This will change the pH balance toward more acidic and caused the
    muscles to lose contractile efficiency. In addition, fatigue can also be studied using rats
    as model organism. Results from this activity can be useful to analyse cellular
    metabolism and physiology effects of the tested rats toward physical exercise.
    Therefore, this review aims to discuss the causes of fatigue through oxidative stress,
    dehydration and lactic acid accumulation. In addition, the effectiveness of using rats as
    a model system in measuring fatigue is also included in illustrating examples on fatigue
    assessment in vivo.
    Matched MeSH terms: Muscle Contraction
  17. Talib I, Sundaraj K, Lam CK, Hussain J, Ali MA
    Eur J Appl Physiol, 2019 Jan;119(1):9-28.
    PMID: 30242464 DOI: 10.1007/s00421-018-3994-9
    PURPOSE: Crosstalk in myographic signals is a major hindrance to the understanding of local information related to individual muscle function. This review aims to analyse the problem of crosstalk in electromyography and mechanomyography.

    METHODS: An initial search of the SCOPUS database using an appropriate set of keywords yielded 290 studies, and 59 potential studies were selected after all the records were screened using the eligibility criteria. This review on crosstalk revealed that signal contamination due to crosstalk remains a major challenge in the application of surface myography techniques. Various methods have been employed in previous studies to identify, quantify and reduce crosstalk in surface myographic signals.

    RESULTS: Although correlation-based methods for crosstalk quantification are easy to use, there is a possibility that co-contraction could be interpreted as crosstalk. High-definition EMG has emerged as a new technique that has been successfully applied to reduce crosstalk.

    CONCLUSIONS: The phenomenon of crosstalk needs to be investigated carefully because it depends on many factors related to muscle task and physiology. This review article not only provides a good summary of the literature on crosstalk in myographic signals but also discusses new directions related to techniques for crosstalk identification, quantification and reduction. The review also provides insights into muscle-related issues that impact crosstalk in myographic signals.

    Matched MeSH terms: Muscle Contraction
  18. Uwamahoro R, Sundaraj K, Subramaniam ID
    Biomed Eng Online, 2021 Jan 03;20(1):1.
    PMID: 33390158 DOI: 10.1186/s12938-020-00840-w
    This research has proved that mechanomyographic (MMG) signals can be used for evaluating muscle performance. Stimulation of the lost physiological functions of a muscle using an electrical signal has been determined crucial in clinical and experimental settings in which voluntary contraction fails in stimulating specific muscles. Previous studies have already indicated that characterizing contractile properties of muscles using MMG through neuromuscular electrical stimulation (NMES) showed excellent reliability. Thus, this review highlights the use of MMG signals on evaluating skeletal muscles under electrical stimulation. In total, 336 original articles were identified from the Scopus and SpringerLink electronic databases using search keywords for studies published between 2000 and 2020, and their eligibility for inclusion in this review has been screened using various inclusion criteria. After screening, 62 studies remained for analysis, with two additional articles from the bibliography, were categorized into the following: (1) fatigue, (2) torque, (3) force, (4) stiffness, (5) electrode development, (6) reliability of MMG and NMES approaches, and (7) validation of these techniques in clinical monitoring. This review has found that MMG through NMES provides feature factors for muscle activity assessment, highlighting standardized electromyostimulation and MMG parameters from different experimental protocols. Despite the evidence of mathematical computations in quantifying MMG along with NMES, the requirement of the processing speed, and fluctuation of MMG signals influence the technique to be prone to errors. Interestingly, although this review does not focus on machine learning, there are only few studies that have adopted it as an alternative to statistical analysis in the assessment of muscle fatigue, torque, and force. The results confirm the need for further investigation on the use of sophisticated computations of features of MMG signals from electrically stimulated muscles in muscle function assessment and assistive technology such as prosthetics control.
    Matched MeSH terms: Muscle Contraction
  19. Hamzaid NA, Tean LT, Davis GM, Suhaimi A, Hasnan N
    Spinal Cord, 2015 May;53(5):375-9.
    PMID: 25366533 DOI: 10.1038/sc.2014.187
    STUDY DESIGN: Prospective study of two cases.

    OBJECTIVES: To describe the effects of electrical stimulation (ES) therapy in the 4-week management of two sub-acute spinal cord-injured (SCI) individuals (C7 American Spinal Injury Association Impairment Scale (AIS) B and T9 AIS (B)).

    SETTING: University Malaya Medical Centre, Kuala Lumpur, Malaysia.

    METHODS: A diagnostic tilt-table test was conducted to confirm the presence of orthostatic hypotension (OH) based on the current clinical definitions. Following initial assessment, subjects underwent 4 weeks of ES therapy 4 times weekly for 1 h per day. Post-tests tilt table challenge, both with and without ES on their rectus abdominis, quadriceps, hamstrings and gastrocnemius muscles, was conducted at the end of the study (week 5). Subjects' blood pressures (BP) and heart rates (HR) were recorded every minute during pre-test and post-tests. Orthostatic symptoms, as well as the maximum tolerance time that the subjects could withstand head up tilt at 60°, were recorded.

    RESULTS: Subject A improved his orthostatic symptoms, but did not recover from clinically defined OH based on the 20-min duration requirement. With concurrent ES therapy, 60° head up tilt BP was 89/62 mm Hg compared with baseline BP of 115/71 mm Hg. Subject B fully recovered from OH demonstrated by BP of 105/71 mm Hg during the 60° head up tilt compared with baseline BP of 124/77 mm Hg. Both patients demonstrated longer tolerance time during head up tilt with concomitant ES (subject A: pre-test 4 min, post-test without ES 6 min, post-test with ES 12 min; subject B: pre-test 4 min, post-test without ES 28 min, post-test with ES 60 min).

    CONCLUSIONS: Weekly ES therapy had positive effect on OH management in sub-acute SCI individuals.

    Matched MeSH terms: Muscle Contraction/physiology*
  20. Oversand SH, Atan IK, Shek KL, Dietz HP
    Int Urogynecol J, 2015 Dec;26(12):1777-81.
    PMID: 26249237 DOI: 10.1007/s00192-015-2793-7
    INTRODUCTION AND HYPOTHESIS: We aimed to compare palpatory and translabial ultrasound (TLUS) measurements of pelvic floor muscle (PFM) function with symptoms and signs of female pelvic organ prolapse (FPOP) to determine a possible association.

    METHODS: We analysed data from 726 women with a mean age of 56 (SD 13.7, range 18-88) years, seen for symptoms of pelvic floor dysfunction between August 2011 and April 2013. The examination included a standardised interview and clinical assessment of FPOP with Pelvic Organ Prolapse Quantification (POP-Q) measurements, Modified Oxford Scale (MOS) grading and 4D TLUS.

    RESULTS: Symptoms of prolapse were reported in 51.4% (373 out of 726) with a mean bother score of 5.8 (SD 2.91, range 0-10). A clinically significant POP (Incontinence Society [ICS]-POP-Q stage ≥ 2) in any compartment was diagnosed in 77.1%. Mean MOS was 2.4 (SD 1.1, range 0-5). Significant POP on TLUS was seen in 54.6% (389 out of 712). TLUS volumes at rest and on maximal PFM contraction were analysed on a desktop PC, to assess the degree of bladder neck (BN) cranioventral shift and levator antero-posterior (AP) diameter reduction, blinded against other data. Mean cranioventral BN shift was 7.11 (SD 4.36, range 0.32-25.32) mm and mean levator AP diameter reduction was 8.6 (SD 4.8, range 0.3-31.3) mm. MOS was strongly associated with subjective and objective POP (P ≤ 0.001), whereas this was not true for TLUS measurements of tissue displacement.

    CONCLUSION: The MOS seems to be a more valid measure of PFM function than sonographically determined BN displacement or reduction of hiatal AP diameter observed on PFM contraction.

    Matched MeSH terms: Muscle Contraction/physiology
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links