Displaying publications 21 - 40 of 42 in total

Abstract:
Sort:
  1. Lee YS, Teo SH, Ahn JH, Lee OS, Lee SH, Lee JH
    Arthroscopy, 2017 Oct;33(10):1884-1895.
    PMID: 28655477 DOI: 10.1016/j.arthro.2017.04.006
    PURPOSE: To evaluate the surgical treatment of the discoid lateral meniscus (DLM) with long-term follow-up and to search which factors are related to good clinical or radiological outcomes.

    METHODS: Search was performed using a MEDLINE, EMBASE, and Cochrane database, and each of the selected studies was evaluated for methodological quality using a risk of bias (ROB) covering 7 criteria. Clinical and radiological outcomes with more than 5 years of follow-up were evaluated after surgical treatment of DLM. They were analyzed according to the age, follow-up period, kind of surgery, DLM type, and alignment.

    RESULTS: Eleven articles (422 DLM cases) were included in the final analysis. Among 7 criteria, 3 criteria showed little ROB in all studies. However, 4 criteria showed some ROB ("Yes" in 63.6% to 81.8%). The minimal follow-up period was 5.5 years (weighted mean follow-up: 9.1 years). Surgical procedures were performed with open or arthroscopic partial central meniscectomy, subtotal meniscectomy, total meniscectomy, or partial meniscectomy with repair. The majority of the studies showed good clinical results. Mild joint space narrowing was reported in the lateral compartment, but none of the knees demonstrated moderate or advanced degenerative changes. Increased age at surgery, longer follow-up period, and subtotal or total meniscectomy could be related to degenerative change. The majority of the complications was osteochondritis dissecans at the lateral femoral condyle (13 cases) and reoperation was performed by osteochondritis dissecans (4 cases), recurrent swelling (2 cases), residual symptom (1 case), stiffness (1 case), and popliteal stenosis (1 case).

    CONCLUSIONS: Good clinical results were obtained with surgical treatment of symptomatic DLM. The progression of degenerative change was minimal and none of the knees demonstrated moderate or advanced degenerative changes. Increased age at surgery, longer follow-up period, and subtotal or total meniscectomy were possible risk factors for degenerative changes.

    LEVEL OF EVIDENCE: Level IV, systematic review of Level IV studies.

    Matched MeSH terms: Knee Joint/surgery*
  2. Lee YS, Lee SH, Lee ES, Fong TS
    BMC Musculoskelet Disord, 2019 Mar 20;20(1):118.
    PMID: 30894158 DOI: 10.1186/s12891-019-2505-4
    BACKGROUND: We report a case of hardware failure after distal femoral osteotomy (DFO) with a broken screw pulled out from the locking hole and positioned within the knee joint.

    CASE PRESENTATION: A 57-year-old man presented to our orthopedic outpatient department with 3-months history of an unusual painful swelling at the operated area following DFO. The leakage of joint fluid from the penetrated suprapatellar pouch was assumed to be the reason for this complication.

    CONCLUSIONS: The overall aim of this case report is to provide a lesson to budding surgeons who might experience a similar situation that cannot be easily explained, like the unexpected complication in the present case.

    Matched MeSH terms: Knee Joint/surgery
  3. Ahmad S, Singh VA, Hussein SI
    J Orthop Surg (Hong Kong), 2017 8 29;25(3):2309499017727946.
    PMID: 28844199 DOI: 10.1177/2309499017727946
    Meniscal allograft transplantation may be a better alternative for the treatment of irreparable meniscal injury compared to other forms of treatment. However, it remains to be seen whether the use fresh frozen allograft is better than cryopreserved allograft in treating this type of injury. We hypothesized that cryopreserved meniscal allograft would work better in maintaining the original biomechanical properties compared to fresh frozen ones, due to the lower amount of damage it incurs during the storage process. We examined young and healthy human menisci obtained from orthopedic oncology patients who underwent resection surgeries around the knee. The menisci obtained were preserved via cryopreservation and deep-freezing process. Traction tests were carried out on the menisci after 6 weeks of preservation. Twelve pairs ( N = 24) of menisci were divided equally into two groups, cryopreservation and deep frozen. There were six males and six female menisci donors for this study. The age range was between 15 and 35 years old (24.9 ± 8.6 years). Cryopreserved specimens had a higher ultimate tensile strength (UTS; 8.2 ± 1.3 Mpa vs. 13.3 ± 1.7 Mpa: p < 0.05) and elastic modulus (61.7 ± 27.6 Mpa vs. 87.0 ± 44.10 Mpa: p < 0.05) compared to the fresh frozen specimens. There was a significant difference in UTS ( p < 0.05) between the two groups but no significant difference in their elastic modulus ( p > 0.05). The elastic modulus of the preserved meniscus was similar to fresh normal menisci taken from other studies (60-120 Mpa; cryopreserved (87.0 ± 44.1) and fresh frozen (61.7 ± 27.5)). Cryopreserved menisci had a higher elastic modulus and point of rupture (UTS) compared to fresh frozen menisci. Cryopreservation proved to be a significantly better method of preservation, among the two methods of preservation in this study.
    Matched MeSH terms: Knee Joint/surgery*
  4. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Knee Joint/surgery*
  5. Jiang L, Bin Abd Razak HR, Chong HC, Tan A
    J Arthroplasty, 2014 Feb;29(2):304-7.
    PMID: 23891052 DOI: 10.1016/j.arth.2013.06.002
    We aim to compare the patient profile and outcomes after TKA between the different racial groups in Singapore. Prospective data were collected from 364 patients who underwent TKA in Singapore General Hospital from January 2006 to May 2010. Patients were stratified according to ethnicity and we compared their preoperative demographic data, Short-Form 36 (SF-36), Oxford Knee (OKS) as well as Knee Society Scores (KSS). Malays were younger (62.0 ± 5.3) at time of surgery (p=0.05) and the body mass index of Chinese (27.9 ± 4.7) was lower than Malay (30.4 ± 5.0) and Indian (31.5 ± 4.5) patients (P<0.005). Malay (40.3 ± 11.0) and Indian (39.2 ± 9.3) patients had less favourable preoperative OKS than Chinese (35.9 ± 7.8) patients (P<0.05). All 3 ethnic groups achieved statistically significant improvements in outcome measures but did not differ significantly between the ethnicities.
    Matched MeSH terms: Knee Joint/surgery*
  6. Kamarul T, Ab-Rahim S, Tumin M, Selvaratnam L, Ahmad TS
    Eur Cell Mater, 2011 Mar 15;21:259-71; discussion 270-1.
    PMID: 21409755
    The effects of Glucosamine Sulphate (GS) and Chondroitin Sulphate (CS) on the healing of damaged and repaired articular cartilage were investigated. This study was conducted using 18 New Zealand white rabbits as experimental models. Focal cartilage defects, surgically created in the medial femoral condyle, were either treated by means of autologous chondrocyte implantation (ACI) or left untreated as controls. Rabbits were then divided into groups which received either GS+/-CS or no pharmacotherapy. Three rabbits from each group were sacrificed at 12 and 24 weeks post-surgery. Knees dissected from rabbits were then evaluated using gross quantification of repair tissue, glycosaminoglycan (GAG) assays, immunoassays and histological assessments. It was observed that, in contrast to untreated sites, surfaces of the ACI-repaired sites appeared smooth and continuous with the surrounding native cartilage. Histological examination demonstrated a typical hyaline cartilage structure; with proteoglycans, type II collagen and GAGs being highly expressed in repair areas. The improved regeneration of these repair sites was also noted to be significant over time (6 months vs. 3 months) and in GS and GS+CS groups compared to the untreated (without pharmacotherapy) group. Combination of ACI and pharmacotherapy (with glucosamine sulphate alone/ or with chondroitin sulphate) may prove beneficial for healing of damaged cartilage, particularly in relation to focal cartilage defects.
    Matched MeSH terms: Knee Joint/surgery
  7. Tai CC, Cross MJ
    J Bone Joint Surg Br, 2006 Sep;88(9):1158-63.
    PMID: 16943464
    We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were = 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up.
    Matched MeSH terms: Knee Joint/surgery
  8. Saw A, Phang ZH, Alrasheed MK, Gunalan R, Albaker MZ, Shanmugam R
    J Orthop Surg (Hong Kong), 2019 9 19;27(3):2309499019873987.
    PMID: 31530084 DOI: 10.1177/2309499019873987
    PURPOSE: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy.

    METHODS: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA).

    RESULTS: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection.

    CONCLUSIONS: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.

    Matched MeSH terms: Knee Joint/surgery*
  9. Silva JF
    Int Orthop, 1980;4(2):79-81.
    PMID: 7429684 DOI: 10.1007/bf00271088
    Two hundred and nineteen patients with skeletal tuberculosis have been reviewed analysing the site of the lesion and the treatment given. Operative management is advocated since the results of this approach are encouraging.
    Matched MeSH terms: Knee Joint/surgery
  10. Fong TS, Kim SC, Kim JE, Lee ES, Kim TW, Lee YS
    J Arthroplasty, 2019 09;34(9):1929-1937.
    PMID: 31138501 DOI: 10.1016/j.arth.2019.04.061
    BACKGROUND: This study aimed at assessing the morphometry of resected femurs in Korean patients during total knee arthroplasty (TKA) and comparing these measurements with current Western-designed femoral component dimensions.

    METHODS: This single-blind, prospective, randomized, controlled trial involved intraoperative measurements for 271 femoral component implantations from 3 contemporary TKA systems, with 2 systems offering narrow sizing options. The difference between femoral component dimensions and the resected surface of distal femur was measured in millimeters at 5 distinct zones.

    RESULTS: Overhang of standard femoral component was common in the anterior-medial condyle and anterior-lateral condyle ranging from 50.8% to 99.0% and 21.5% to 88.0%, respectively. With narrow femoral components, the rate of overhang reduced to 21.5%-30.2% and 9.2%-32.1%. Conversely, underhang rates were higher over the anterior flange width, middle medial-lateral and posterior medial-lateral zones. Standard components displayed higher underhang rates at these zones compared to narrow components. The good fit rate for femoral component was low among the 3 systems ranging from 1.0% to 56.0%. System with narrow option sizing increases the underhang rates in males, while improving the component fit among females at similar zones with rate ranging from 5.2% to 52.9%.

    CONCLUSION: Currently available TKA implant designs may not provide a perfect match for the distal femoral shape of the Korean population. The availability of implants with standard and narrow options can substantially improve the optimal fitting of femoral components in the Korean population.

    Matched MeSH terms: Knee Joint/surgery*
  11. Kim JE, Won S, Jaffar MSA, Lee JI, Kim TW, Lee YS
    Knee, 2020 Jun;27(3):940-948.
    PMID: 32331827 DOI: 10.1016/j.knee.2020.04.008
    BACKGROUND: Open-wedge high tibial osteotomy (OWHTO) produces three- dimensional (3D) geometric changes. Among them, increased posterior tibial slope (PTS), and altered coronal inclination that induces unintended tibial translation may affect anterior cruciate ligament (ACL) status. The purpose of current study was to evaluate the geometric changes following OWHTO, such as increasing PTS and decreasing tibial subluxation, which may affect the status of ACL.

    METHODS: From April 2014 to December 2015, a total of 72 knees in 64 patients that underwent OWHTO, second-look arthroscopy, and magnetic resonance imaging (MRI) assessment, were enrolled. Preoperative and postoperative coronal and sagittal translation, joint line orientation angle, the distance between medial femoral notch marginal line and medial tibial spine, and PTS were evaluated. ACL status was arthroscopically graded from grade 1 (best) to 4 (worst). The MRI signal of the graft in three portions (proximal, middle, and distal) was graded from grade 1 (best) to 4 (worst).

    RESULTS: High grade (3: partial, and 4: complete rupture) was noted in 28 cases (38.9%) at the second-look arthroscopy compared with 10 cases (13.9%) at index arthroscopy. The MRI signal grade significantly increased at follow up MRI compared with preoperative MRI (P<0.01). An increased signal was commonly noted in the middle and distal portions of the graft.

    CONCLUSIONS: Geometric changes after OWHTO were related to ACL deterioration. The ACL was commonly affected at the middle and distal portions and rarely at the proximal portion. There is a possibility of impingement because of the geometric changes.

    LEVEL OF EVIDENCE: Level IV.

    Matched MeSH terms: Knee Joint/surgery
  12. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Knee Joint/surgery*
  13. Sharifah MI, Lee CL, Suraya A, Johan A, Syed AF, Tan SP
    Knee Surg Sports Traumatol Arthrosc, 2015 Mar;23(3):826-30.
    PMID: 24240983 DOI: 10.1007/s00167-013-2766-7
    PURPOSE: This study was conducted to evaluate the accuracy of magnetic resonance imaging (MRI) in diagnosing meniscal tears in patients with anterior cruciate ligament (ACL) tears and to determine the frequency of missed meniscal tears on MRI.

    METHODS: This prospective comparative study was conducted from 2009 to 2012. Patients with ACL injuries who underwent knee arthroscopy and MRI were included in the study. Two radiologists who were blinded to the clinical history and arthroscopic findings reviewed the pre-arthroscopic MR images. The presence and type of meniscal tears on MRI and arthroscopy were recorded. Arthroscopic findings were used as the reference standard. The accuracy, sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of MRI in the evaluation of meniscal tears were calculated.

    RESULTS: A total of 65 patients (66 knees) were included. The sensitivity, specificity, accuracy, PPV, and NPV for the MRI diagnosis of lateral meniscal tears in our patients were 83, 97, 92, 96, and 90 %, respectively, whereas those for medial meniscus tears were 82, 92, 88, 82, and 88 %, respectively. There were five false-negative diagnoses of medial meniscus tears and four false-negative diagnoses of lateral meniscus tears. The majority of missed meniscus tears on MRI affected the peripheral posterior horns.

    CONCLUSION: The sensitivity for diagnosing a meniscal tear was significantly higher when the tear involved more than one-third of the meniscus or the anterior horn. The sensitivity was significantly lower for tears located in the posterior horn and for vertically oriented tears. Therefore, special attention should be given to the peripheral posterior horns of the meniscus, which are common sites of injury that could be easily missed on MRI. The high NPVs obtained in this study suggest that MRI is a valuable tool prior to arthroscopy.

    Matched MeSH terms: Knee Joint/surgery*
  14. Rao SK, Rao PS
    Med J Malaysia, 2005 Dec;60(5):560-2.
    PMID: 16515105
    Post Arthroscopic intra-articular analgesia is a better method to avoid post-operative pain after arthroscopic surgery, thus avoiding the adverse effects of systemic analgesics. In this prospective randomized double blind study conducted on 90 patients, 30 patients in group A received 20 ml of intra-articular saline, 30 patients in Group B received 10 ml of intra-articular saline and 10 ml of 0.25% bupivacaine and 30 patients in Group C received 10 ml of 0.25% bupivacaine, 1 ml (30 mg) of ketorolac and 9 ml of saline intra-articularly. Ambulatory status, duration of analgesia and requirement for supplemented analgesia were compared in these three groups. Patients receiving this intra-articular analgesic combination of bupivacaine and ketorolac required significantly less supplemental postoperative analgesics. This combination significantly prolonged the duration of analgesia. Patients receiving this combination of drugs for intra-articular analgesia ambulated earlier.
    Matched MeSH terms: Knee Joint/surgery
  15. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
    Matched MeSH terms: Knee Joint/surgery
  16. Saw KY, Anz A, Jee CS, Ng RC, Mohtarrudin N, Ragavanaidu K
    Arthroscopy, 2015 Oct;31(10):1909-20.
    PMID: 26008951 DOI: 10.1016/j.arthro.2015.03.038
    PURPOSE: To histologically evaluate the quality of articular cartilage regeneration from the medial compartment after arthroscopic subchondral drilling followed by postoperative intra-articular injections of autologous peripheral blood stem cells (PBSCs) and hyaluronic acid with concomitant medial open-wedge high tibial osteotomy (HTO) in patients with varus deformity of the knee joint.
    METHODS: Eight patients with varus deformity of the knee joint underwent arthroscopic subchondral drilling of International Cartilage Repair Society (ICRS) grade 4 bone-on-bone lesions of the medial compartment with concomitant HTO. These patients were part of a larger pilot study in which 18 patients underwent the same procedure. PBSCs were harvested and cryopreserved preoperatively. At 1 week after surgery, 8 mL of PBSCs was mixed with 2 mL of hyaluronic acid and injected intra-articularly into the knee joint; this was repeated once a week for 5 consecutive weeks. Three additional intra-articular injections were administered weekly at intervals of 6, 12, and 18 months postoperatively. Informed consent was obtained at the time of hardware removal for opportunistic second-look arthroscopy and chondral biopsy. Biopsy specimens were stained with H&E, safranin O, and immunohistochemical staining for type I and II collagen. Specimens were graded using the 14 components of the ICRS Visual Assessment Scale II, and a total score was obtained.
    RESULTS: Second-look arthroscopy showed satisfactory healing of the regenerated cartilage. Histologic analysis showed significant amounts of proteoglycan and type II collagen. The total ICRS Visual Assessment Scale II histologic scores comparing the regenerated articular cartilage (mean, 1,274) with normal articular cartilage (mean, 1,340) indicated that the repair cartilage score approached 95% of the normal articular cartilage score. There were no infections, delayed unions, or nonunions.
    CONCLUSIONS: Chondrogenesis with stem cells in combination with medial open-wedge HTO for varus deformity correction of the knee joint regenerates cartilage that closely resembles the native articular cartilage.
    LEVEL OF EVIDENCE: Level IV, therapeutic case series.
    Matched MeSH terms: Knee Joint/surgery
  17. Ramanathan R
    Med J Malaysia, 1998 Sep;53 Suppl A:99-101.
    PMID: 10968190
    We studied 95 patients who underwent knee Arthroscopy under local anaesthesia between JANUARY 1995 till 1997. Materials used were 1% Xylocaine and 0.25% Bupivacaine of 20 mls each combined with midazolam 2 mg and IV pethidine 30 mgm for sedation. The patients were attached to monitors (pulse Oxymeter, ECG and BP and pulse recorders) and blood less field was created using a tornquet. The procedures lasted about 45 minutes. 90 out of 95 patients completed the procedures successfully without any complications. 2 developed respiratory embarrassments and were intubated and ventilated. 3 procedures abandoned and converted to general anaesthesia. The range of procedures done include meniscectomy, meniscal repair, synovial biopsy, debridement for osteoarthrosis, shaving of osteophytes, drilling of cartilage and bones and removal of loose bodies. This study is to show that knee arthroscopy under LA is a safe alternative in hospitals where GA time is limited.
    Matched MeSH terms: Knee Joint/surgery*
  18. Siow WM, Chin PL, Chia SL, Lo NN, Yeo SJ
    Clin Orthop Relat Res, 2013 May;471(5):1451-7.
    PMID: 23299954 DOI: 10.1007/s11999-012-2776-7
    There is marked racial disparity in TKA use rates, demographics, and outcomes between white and Afro-Caribbean Americans. Comparative studies of ethnicity in patients undergoing TKAs have been mostly in American populations with an underrepresentation of Asian groups. It is unclear whether these disparities exist in Chinese, Malays, and Indians.
    Matched MeSH terms: Knee Joint/surgery*
  19. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Knee Joint/surgery*
  20. Wong KA, Singh VA, Pailoor J
    Singapore Med J, 2013 Nov;54(11):e228-9.
    PMID: 24276110
    Intra-articular haemangioma is a rare and uncommon condition that sometimes presents in infants. The lesion can be a diagnostic challenge, with misdiagnosis often leading to delayed diagnosis and treatment. It is essential to establish and treat the condition early, as intra-articular haemangioma can lead to destruction of the joint and secondary arthrosis. Herein, we report the case of a five-year-old boy who presented with intra-articular haemangioma and discuss the management of his condition.
    Matched MeSH terms: Knee Joint/surgery*