Displaying publications 21 - 39 of 39 in total

Abstract:
Sort:
  1. Ishak WS, Zhao F, Rajenderkumar D, Arif M
    Int Tinnitus J, 2013;18(1):35-44.
    PMID: 24995898 DOI: 10.5935/0946-5448.20130006
    The general consensus on the roles of hearing loss in triggering tinnitus seems not applicable in patients with normal hearing thresholds. The absence of hearing loss on the audiogram in this group of patients poses a serious challenge to the cochlear theories in explaining tinnitus generation in this group of patients.
    Matched MeSH terms: Auditory Threshold/physiology*
  2. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Auditory Threshold/radiation effects
  3. Tang IP, Prepageran N, Raman R, Sharizhal T
    J Laryngol Otol, 2009 Dec;123(12):1321-4.
    PMID: 19835642 DOI: 10.1017/S0022215109990806
    To determine whether epithelial migration in the atelectatic tympanic membrane (secondary to any pathology) occurs in a similar fashion to that in the normal (non-pathological) tympanic membrane, by calculating and comparing the epithelial migration rate and pattern.
    Matched MeSH terms: Auditory Threshold/physiology
  4. Dzulkarnain AAA, Abdullah SA, Ruzai MAM, Ibrahim SHMN, Anuar NFA, Rahim 'EA
    Am J Audiol, 2018 Sep 12;27(3):294-305.
    PMID: 30054628 DOI: 10.1044/2018_AJA-17-0087
    Purpose: The purpose of this study was to investigate the influence of 2 different electrode montages (ipsilateral and vertical) on the auditory brainstem response (ABR) findings elicited from narrow band (NB) level-specific (LS) CE-Chirp and tone-burst in subjects with normal hearing at several intensity levels and frequency combinations.

    Method: Quasi-experimental and repeated-measures study designs were used in this study. Twenty-six adults with normal hearing (17 females, 9 males) participated. ABRs were acquired from the study participants at 3 intensity levels (80, 60, and 40 dB nHL), 3 frequencies (500, 1000, and 2000 Hz), 2 electrode montages (ipsilateral and vertical), and 2 stimuli (NB LS CE-Chirp and tone-burst) using 2 stopping criteria (fixed averages at 4,000 sweeps and F test at multiple points = 3.1).

    Results: Wave V amplitudes were only 19%-26% larger for the vertical recordings than the ipsilateral recordings in both the ABRs obtained from the NB LS CE-Chirp and tone-burst stimuli. The mean differences in the F test at multiple points values and the residual noise levels between the ABRs obtained from the vertical and ipsilateral montages were statistically not significant. In addition, the ABR elicited from the NB LS CE-Chirp was significantly larger (up to 69%) than those from the tone-burst, except at the lower intensity level.

    Conclusion: Both the ipsilateral and vertical montages can be used to record ABR to the NB LS CE-Chirp because of the small enhancement in the wave V amplitude provided by the vertical montage.

    Matched MeSH terms: Auditory Threshold/physiology*
  5. Ami M, Abdullah A, Awang MA, Liyab B, Saim L
    Laryngoscope, 2008 Apr;118(4):712-7.
    PMID: 18176342 DOI: 10.1097/MLG.0b013e318161e521
    To investigate cochlear outer hair cell function based on distortion product otoacoustic emission (DPOAE) in patients with tinnitus.
    Matched MeSH terms: Auditory Threshold/physiology*
  6. Ho EC, Ong WMW, Li K, Zhang H, Bei YTE, Medapati SVR, et al.
    Int J Audiol, 2018 10;57(10):776-783.
    PMID: 29957077 DOI: 10.1080/14992027.2018.1476781
    OBJECTIVE: To examine the factors associated with late presentation at first hearing aid (HA) fitting, HA choice and usage among users in Singapore.

    DESIGN: Retrospective cross-sectional study.

    STUDY SAMPLE: 1068 subjects issued with HAs at a tertiary hospital from 2001 to 2013.

    RESULTS: Half of the subjects presented with more severe (>55 dB) hearing loss (HL) in their better ear. In multivariable analysis, older age, Malay ethnicity, conductive and mixed HL, and combination type of HL were associated with more severe HL at first presentation. Over 70% of subjects were older than 65 years. Worse pure tone audiometry (PTA) thresholds of the better ear, gradual onset and sensorineural HL were associated with older age presentation. For unilaterally fitted subjects, PTA thresholds were the only determinant of having the better ear aided. Better PTA thresholds, younger age and sensorineural HL were associated with choosing in ear compared to behind the ear HAs. Younger age and worse PTA of the better ear were associated with ≥4 h of daily HA usage.

    CONCLUSIONS: Age, ethnicity and type of HL were important determinants for more severe HL at first HA fitting. Older patients and those with better hearing were less likely to use their HAs regularly.

    Matched MeSH terms: Auditory Threshold*
  7. Dewey RS, Francis ST, Guest H, Prendergast G, Millman RE, Plack CJ, et al.
    Neuroimage, 2020 Jan 01;204:116239.
    PMID: 31586673 DOI: 10.1016/j.neuroimage.2019.116239
    In animal models, exposure to high noise levels can cause permanent damage to hair-cell synapses (cochlear synaptopathy) for high-threshold auditory nerve fibers without affecting sensitivity to quiet sounds. This has been confirmed in several mammalian species, but the hypothesis that lifetime noise exposure affects auditory function in humans with normal audiometric thresholds remains unconfirmed and current evidence from human electrophysiology is contradictory. Here we report the auditory brainstem response (ABR), and both transient (stimulus onset and offset) and sustained functional magnetic resonance imaging (fMRI) responses throughout the human central auditory pathway across lifetime noise exposure. Healthy young individuals aged 25-40 years were recruited into high (n = 32) and low (n = 30) lifetime noise exposure groups, stratified for age, and balanced for audiometric threshold up to 16 kHz fMRI demonstrated robust broadband noise-related activity throughout the auditory pathway (cochlear nucleus, superior olivary complex, nucleus of the lateral lemniscus, inferior colliculus, medial geniculate body and auditory cortex). fMRI responses in the auditory pathway to broadband noise onset were significantly enhanced in the high noise exposure group relative to the low exposure group, differences in sustained fMRI responses did not reach significance, and no significant group differences were found in the click-evoked ABR. Exploratory analyses found no significant relationships between the neural responses and self-reported tinnitus or reduced sound-level tolerance (symptoms associated with synaptopathy). In summary, although a small effect, these fMRI results suggest that lifetime noise exposure may be associated with central hyperactivity in young adults with normal hearing thresholds.
    Matched MeSH terms: Auditory Threshold/physiology*
  8. Sulaiman AH, Husain R, Seluakumaran K
    J Int Adv Otol, 2015 Aug;11(2):104-9.
    PMID: 26380997 DOI: 10.5152/iao.2015.699
    The usage of personal listening devices (PLDs) is associated with risks of hearing loss. The aim of this study is to evaluate the effects of music exposure from these devices on high-frequency hearing thresholds of PLD users.
    Matched MeSH terms: Auditory Threshold
  9. Hossain ME, Jassim WA, Zilany MS
    PLoS One, 2016;11(3):e0150415.
    PMID: 26967160 DOI: 10.1371/journal.pone.0150415
    Sensorineural hearing loss occurs due to damage to the inner and outer hair cells of the peripheral auditory system. Hearing loss can cause decreases in audibility, dynamic range, frequency and temporal resolution of the auditory system, and all of these effects are known to affect speech intelligibility. In this study, a new reference-free speech intelligibility metric is proposed using 2-D neurograms constructed from the output of a computational model of the auditory periphery. The responses of the auditory-nerve fibers with a wide range of characteristic frequencies were simulated to construct neurograms. The features of the neurograms were extracted using third-order statistics referred to as bispectrum. The phase coupling of neurogram bispectrum provides a unique insight for the presence (or deficit) of supra-threshold nonlinearities beyond audibility for listeners with normal hearing (or hearing loss). The speech intelligibility scores predicted by the proposed method were compared to the behavioral scores for listeners with normal hearing and hearing loss both in quiet and under noisy background conditions. The results were also compared to the performance of some existing methods. The predicted results showed a good fit with a small error suggesting that the subjective scores can be estimated reliably using the proposed neural-response-based metric. The proposed metric also had a wide dynamic range, and the predicted scores were well-separated as a function of hearing loss. The proposed metric successfully captures the effects of hearing loss and supra-threshold nonlinearities on speech intelligibility. This metric could be applied to evaluate the performance of various speech-processing algorithms designed for hearing aids and cochlear implants.
    Matched MeSH terms: Auditory Threshold
  10. Maisarah SZ, Said H
    Med J Malaysia, 1993 Sep;48(3):280-5.
    PMID: 8183139
    A total of 524 industrial workers were studied. They consisted of 442 noise exposed and 82 non-noise exposed workers. The purpose was to compare the prevalence of sensori-neural hearing loss among the noise exposed and the non-noise exposed workers, to study their knowledge on the hazard of noise to hearing and the workers' attitude towards the hearing protection devices. The prevalence of sensori-neural hearing loss was significantly higher among the noise exposed workers, i.e., 83% versus 31.7% (p < 0.01). However, the prevalence of hearing impairment was much lower for both groups, being 30.1% for the noise exposed and 3.7% for the non-noise exposed group. Although hearing protection devices were provided to 80.5% of the workers, only 5.1% were wearing them regularly. The possibility of developing hearing loss due to exposure to excessive noise was only known by 35.5% of the noise exposed workers. This awareness was found to have a positive correlation with the workers' compliance to the hearing protection devices. Our findings highlight the need for workers to be educated on the hazards of excessive noise exposure to hearing.
    Matched MeSH terms: Auditory Threshold
  11. Quar TK, Soli SD, Chan YF, Ishak WS, Abdul Wahat NH
    Int J Audiol, 2017 02;56(2):92-98.
    PMID: 27686009 DOI: 10.1080/14992027.2016.1210828
    OBJECTIVE: This study was conducted to evaluate the speech perception of Malaysian Chinese adults using the Taiwanese Mandarin HINT (MHINT-T) and the Malay HINT (MyHINT).

    DESIGN: The MHINT-T and the MyHINT were presented in quiet and noise (front, right and left) conditions under headphones. Results for the two tests were compared with each other and with the norms for each test.

    STUDY SAMPLE: Malaysian Chinese native speakers of Mandarin (N = 58), 18-31 years of age with normal hearing.

    RESULTS: On average, subjects demonstrated poorer speech perception ability than the normative samples for these tests. Repeated measures ANOVA showed that speech reception thresholds (SRTs) were slightly poorer on the MHINT-T than on the MyHINT for all test conditions. However, normalized SRTs were poorer by 0.6 standard deviations for MyHINT as compared with MHINT-T.

    CONCLUSIONS: MyHINT and MHINT-T can be used as norm-referenced speech perception measures for Mandarin-speaking Chinese in Malaysia.

    Matched MeSH terms: Auditory Threshold
  12. Arvin B, Prepageran N, Raman R
    Indian J Otolaryngol Head Neck Surg, 2013 Dec;65(Suppl 3):480-4.
    PMID: 24427701 DOI: 10.1007/s12070-011-0356-x
    The objective of this study is to determine whether presbycusis occurs much earlier than previously believed if the high frequency (above 8 kHz) are included. Tertiary referral center (a teaching University). This is a cross-sectional observational study. Healthy adults from 20 to 49 years of age who had essentially normal hearing were included into the study. They were subjected to high frequency pure tone audiometry (until 16 kHz). Participants were grouped based on age ranges of 10 years (e.g., 20-29, 30-39, and 40-49) and the presence of symmetrical high frequency sensor neural hearing loss were documented. There is a significant presence of symmetrical high frequency sensor neural hearing loss (not attributed to any known risk factors) as early as from the age group of 40 to 49 years. Seven of 43 participants (16%) from age group of 20 to 29 years and 12 of 24 participants (50%) from age group of 30 to 39 years had significant high frequency hearing loss. High frequency hearing loss (high frequency Presbycusis) may occur much earlier than previously believed.
    Matched MeSH terms: Auditory Threshold
  13. Sayapathi BS, Su AT, Koh D
    J Occup Health, 2014;56(1):1-11.
    PMID: 24270928
    OBJECTIVES: A systematic review was conducted to identify the effectiveness of different permissible exposure limits in preserving the hearing threshold level. This review compared the limits of the US National Institute of Occupational Safety and Health with those of the US Occupational Safety and Health Administration. The prevalence of occupational noise-induced hearing loss is on an increasing trend globally. This review was performed to reduce the prevalence of noise-induced hearing loss.

    METHODS: We searched 3 major databases, i.e., PubMed, Embase and Lippincott Williams & Wilkins Journals@Ovid, for studies published up until 1May 2013 without language restrictions. All study designs were included in this review. The studies were identified and retrieved by two independent authors.

    RESULTS: Of 118 titles scanned, 14 duplicates were removed, and a total of 13 abstracts from all three databases were identified for full-text retrieval. From the full text, eight articles met the inclusion criteria for this systematic review. These articles showed acceptable quality based on our scoring system. Most of the studies indicated that temporary threshold shifts were much lower when subjects were exposed to a noise level of 85 dBA or lower.

    CONCLUSIONS: There were more threshold shifts in subjects adopting 90 dBA compared with 85 dBA. These temporary threshold shifts may progress to permanent shifts over time. Action curtailing noise exposure among employees would be taken earlier on adoption of 85 dBA as the permissible exposure limit, and hence prevalence of noise-induced hearing loss may be reduced.

    Matched MeSH terms: Auditory Threshold/physiology
  14. Gendeh BS, Gibb AG, Aziz NS, Kong N, Zahir ZM
    Otolaryngol Head Neck Surg, 1998 Apr;118(4):551-8.
    PMID: 9560111
    A prospective study was undertaken in 16 patients with chronic renal failure on continuous ambulatory peritoneal dialysis, with 22 episodes of peritonitis treated with vancomycin, a known ototoxic agent. Twelve patients had one episode each, and four had recurrent peritonitis. Each treatment course consisted of two infusions of vancomycin (30 mg/kg body weight) in 2 L of peritoneal dialysate administered at 6-day intervals. Serum vancomycin analyzed by enzyme immunoassay showed a mean trough level of 11.00 microg/ml on day 6 and mean serum levels of 33.8 and 38.6 microg/ml about 12 hours after administration on days 1 and 7, respectively. Similar levels, well within the therapeutic range, were encountered with repeated vancomycin therapy for recurrent episodes of peritonitis, suggesting that no changes occurred in the pharmacokinetic profile of the drug. Pure-tone audiometry, electronystagmography, and clinical assessment performed during each course of treatment showed no evidence of ototoxicity even on repeated courses of vancomycin therapy. The results suggest that vancomycin therapy when given in appropriate concentrations as a single therapeutic agent is both effective and safe. We believe, however, that vancomycin administered in combination with an aminoglycoside may produce ototoxic effects that may be greatly aggravated, possibly because of synergism.
    Matched MeSH terms: Auditory Threshold/drug effects
  15. Rahmat S, O'Beirne GA
    Hear Res, 2015 Dec;330(Pt A):125-33.
    PMID: 26209881 DOI: 10.1016/j.heares.2015.07.013
    Schroeder-phase masking complexes have been used in many psychophysical experiments to examine the phase curvature of cochlear filtering at characteristic frequencies, and other aspects of cochlear nonlinearity. In a normal nonlinear cochlea, changing the "scalar factor" of the Schroeder-phase masker from -1 through 0 to +1 results in a marked difference in the measured masked thresholds, whereas this difference is reduced in ears with damaged outer hair cells. Despite the valuable information it may give, one disadvantage of the Schroeder-phase masking procedure is the length of the test - using the conventional three-alternative forced-choice technique to measure a masking function takes around 45 min for one combination of probe frequency and intensity. As an alternative, we have developed a fast method of recording these functions which uses a Békésy tracking procedure. Testing at 500 Hz in normal hearing participants, we demonstrate that our fast method: i) shows good agreement with the conventional method; ii) shows high test-retest reliability; and iii) shortens the testing time to 8 min.
    Matched MeSH terms: Auditory Threshold
  16. Dzulkarnain AAA, Noor Ibrahim SHM, Anuar NFA, Abdullah SA, Tengku Zam Zam TZH, Rahmat S, et al.
    Int J Audiol, 2017 Oct;56(10):723-732.
    PMID: 28415891 DOI: 10.1080/14992027.2017.1313462
    OBJECTIVE: To investigate the influence of two different electrode montages (ipsilateral: reference to mastoid and vertical: reference to nape of neck) to the ABR results recorded using a level-specific (LS)-CE-Chirp® in normally hearing subjects at multiple intensities levels.

    DESIGN: Quasi-experimental and repeated measure study designs were applied in this study. Two different stopping criteria were used, (1) a fixed-signal averaging 4000 sweeps and, (2) a minimum quality indicator of Fmp = 3.1 with a minimum of 800 sweeps.

    STUDY SAMPLE: Twenty-nine normally hearing adults (18 females, 11 male) participated.

    RESULTS: Wave V amplitudes were significantly larger in the LS CE-Chirp® recorded from the vertical montage than the ipsilateral montage. Waves I and III amplitudes were significantly larger from the ipsilateral LS CE-Chirp® than from the other montages and stimulus combinations. The differences in the quality of the ABR recording between the vertical and ipsilateral montages were marginal.

    CONCLUSIONS: Overall, the result suggested that the vertical LS CE-Chirp® ABR had a high potential for a threshold-seeking application, because it produced a higher wave V amplitude. The Ipsilateral LS CE-Chirp® ABR, on the other hand, might also have a high potential for the site of lesion application, because it produced larger waves I and III amplitudes.

    Matched MeSH terms: Auditory Threshold
  17. Abdelatti ZAS, Hartbauer M
    Hear Res, 2017 11;355:70-80.
    PMID: 28974384 DOI: 10.1016/j.heares.2017.09.011
    In forest clearings of the Malaysian rainforest, chirping and trilling Mecopoda species often live in sympatry. We investigated whether a phenomenon known as stochastic resonance (SR) improved the ability of individuals to detect a low-frequent signal component typical of chirps when members of the heterospecific trilling species were simultaneously active. This phenomenon may explain the fact that the chirping species upholds entrainment to the conspecific song in the presence of the trill. Therefore, we evaluated the response probability of an ascending auditory neuron (TN-1) in individuals of the chirping Mecopoda species to triple-pulsed 2, 8 and 20 kHz signals that were broadcast 1 dB below the hearing threshold while increasing the intensity of either white noise or a typical triller song. Our results demonstrate the existence of SR over a rather broad range of signal-to-noise ratios (SNRs) of input signals when periodic 2 kHz and 20 kHz signals were presented at the same time as white noise. Using the chirp-specific 2 kHz signal as a stimulus, the maximum TN-1 response probability frequently exceeded the 50% threshold if the trill was broadcast simultaneously. Playback of an 8 kHz signal, a common frequency band component of the trill, yielded a similar result. Nevertheless, using the trill as a masker, the signal-related TN-1 spiking probability was rather variable. The variability on an individual level resulted from correlations between the phase relationship of the signal and syllables of the trill. For the first time, these results demonstrate the existence of SR in acoustically-communicating insects and suggest that the calling song of heterospecifics may facilitate the detection of a subthreshold signal component in certain situations. The results of the simulation of sound propagation in a computer model suggest a wide range of sender-receiver distances in which the triller can help to improve the detection of subthreshold signals in the chirping species.
    Matched MeSH terms: Auditory Threshold
  18. Govindaraju R, Omar R, Rajagopalan R, Norlisah R, Kwan-Hoong N
    Auris Nasus Larynx, 2011 Aug;38(4):519-22.
    PMID: 21236610 DOI: 10.1016/j.anl.2010.12.006
    The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effects of a 3 T MRI generated noise on the auditory system. Our patient underwent investigation of his chronic backache in a 3 T MRI unit and developed hearing loss and tinnitus post-MRI examination. Hearing assessment was done using pure tone audiogram, distortion product otoacoustic emission (DPOAE) and brainstem electrical response audiometry (BERA) which revealed a unilateral sensorineural hearing loss which recovered within 3 days. However the tinnitus persisted. This is possibly a case of temporary threshold shift following noise exposure. However a sudden sensorineural hearing loss remains the other possibility.
    Matched MeSH terms: Auditory Threshold
  19. Quar TK, Ching TY, Newall P, Sharma M
    Int J Audiol, 2013 May;52(5):322-32.
    PMID: 23570290 DOI: 10.3109/14992027.2012.755740
    The study aims to compare the performance of hearing aids fitted according to the NAL-NL1 and DSL v5 prescriptive procedure for children.
    Matched MeSH terms: Auditory Threshold
Filters
Contact Us

Please provide feedback to Administrator ([email protected])