Method: Quasi-experimental and repeated-measures study designs were used in this study. Twenty-six adults with normal hearing (17 females, 9 males) participated. ABRs were acquired from the study participants at 3 intensity levels (80, 60, and 40 dB nHL), 3 frequencies (500, 1000, and 2000 Hz), 2 electrode montages (ipsilateral and vertical), and 2 stimuli (NB LS CE-Chirp and tone-burst) using 2 stopping criteria (fixed averages at 4,000 sweeps and F test at multiple points = 3.1).
Results: Wave V amplitudes were only 19%-26% larger for the vertical recordings than the ipsilateral recordings in both the ABRs obtained from the NB LS CE-Chirp and tone-burst stimuli. The mean differences in the F test at multiple points values and the residual noise levels between the ABRs obtained from the vertical and ipsilateral montages were statistically not significant. In addition, the ABR elicited from the NB LS CE-Chirp was significantly larger (up to 69%) than those from the tone-burst, except at the lower intensity level.
Conclusion: Both the ipsilateral and vertical montages can be used to record ABR to the NB LS CE-Chirp because of the small enhancement in the wave V amplitude provided by the vertical montage.
DESIGN: Retrospective cross-sectional study.
STUDY SAMPLE: 1068 subjects issued with HAs at a tertiary hospital from 2001 to 2013.
RESULTS: Half of the subjects presented with more severe (>55 dB) hearing loss (HL) in their better ear. In multivariable analysis, older age, Malay ethnicity, conductive and mixed HL, and combination type of HL were associated with more severe HL at first presentation. Over 70% of subjects were older than 65 years. Worse pure tone audiometry (PTA) thresholds of the better ear, gradual onset and sensorineural HL were associated with older age presentation. For unilaterally fitted subjects, PTA thresholds were the only determinant of having the better ear aided. Better PTA thresholds, younger age and sensorineural HL were associated with choosing in ear compared to behind the ear HAs. Younger age and worse PTA of the better ear were associated with ≥4 h of daily HA usage.
CONCLUSIONS: Age, ethnicity and type of HL were important determinants for more severe HL at first HA fitting. Older patients and those with better hearing were less likely to use their HAs regularly.
DESIGN: The MHINT-T and the MyHINT were presented in quiet and noise (front, right and left) conditions under headphones. Results for the two tests were compared with each other and with the norms for each test.
STUDY SAMPLE: Malaysian Chinese native speakers of Mandarin (N = 58), 18-31 years of age with normal hearing.
RESULTS: On average, subjects demonstrated poorer speech perception ability than the normative samples for these tests. Repeated measures ANOVA showed that speech reception thresholds (SRTs) were slightly poorer on the MHINT-T than on the MyHINT for all test conditions. However, normalized SRTs were poorer by 0.6 standard deviations for MyHINT as compared with MHINT-T.
CONCLUSIONS: MyHINT and MHINT-T can be used as norm-referenced speech perception measures for Mandarin-speaking Chinese in Malaysia.
METHODS: We searched 3 major databases, i.e., PubMed, Embase and Lippincott Williams & Wilkins Journals@Ovid, for studies published up until 1May 2013 without language restrictions. All study designs were included in this review. The studies were identified and retrieved by two independent authors.
RESULTS: Of 118 titles scanned, 14 duplicates were removed, and a total of 13 abstracts from all three databases were identified for full-text retrieval. From the full text, eight articles met the inclusion criteria for this systematic review. These articles showed acceptable quality based on our scoring system. Most of the studies indicated that temporary threshold shifts were much lower when subjects were exposed to a noise level of 85 dBA or lower.
CONCLUSIONS: There were more threshold shifts in subjects adopting 90 dBA compared with 85 dBA. These temporary threshold shifts may progress to permanent shifts over time. Action curtailing noise exposure among employees would be taken earlier on adoption of 85 dBA as the permissible exposure limit, and hence prevalence of noise-induced hearing loss may be reduced.
DESIGN: Quasi-experimental and repeated measure study designs were applied in this study. Two different stopping criteria were used, (1) a fixed-signal averaging 4000 sweeps and, (2) a minimum quality indicator of Fmp = 3.1 with a minimum of 800 sweeps.
STUDY SAMPLE: Twenty-nine normally hearing adults (18 females, 11 male) participated.
RESULTS: Wave V amplitudes were significantly larger in the LS CE-Chirp® recorded from the vertical montage than the ipsilateral montage. Waves I and III amplitudes were significantly larger from the ipsilateral LS CE-Chirp® than from the other montages and stimulus combinations. The differences in the quality of the ABR recording between the vertical and ipsilateral montages were marginal.
CONCLUSIONS: Overall, the result suggested that the vertical LS CE-Chirp® ABR had a high potential for a threshold-seeking application, because it produced a higher wave V amplitude. The Ipsilateral LS CE-Chirp® ABR, on the other hand, might also have a high potential for the site of lesion application, because it produced larger waves I and III amplitudes.