MATERIALS AND METHODS: Total 120 freshly extracted human mandibular incisor teeth were collected and separated into six subgroups of 20 teeth each. Two different wires, a 0.036 inch hard round stainless steel (HRSS) wire sandblasted at the ends and 0.0175 inch multistranded wire bonded onto the lingual surfaces of the incisors with three different types of composite resins of 3M company; Concise Orthodontic (self-cure), Transbond XT (light-cure) and Transbond LR (light-cure). Specimens were further sealed with a nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-composite and wire-composite interfaces. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney U-tests.
RESULTS: For HRSS wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05). At the wire composite interface too, the microleakage was in order of Transbond LR
PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical behavior (stress distribution pattern) in the mandibular overdenture, mucosa, bone, and implants when retained with 2 standard implants or 2 mini implants under unilateral or bilateral loading conditions.
MATERIAL AND METHODS: A patient with edentulous mandible and his denture was scanned with cone beam computed tomography (CBCT), and a 3D mandibular model was created in the Mimics software program by using the CBCT digital imaging and communications in medicine (DICOM) images. The model was transferred to the 3Matics software program to form a 2-mm-thick mucosal layer and to assemble the denture DICOM file. A 12-mm-long standard implant (Ø3.5 mm) and a mini dental implant (Ø2.5 mm) along with the LOCATOR male attachments (height 4 mm) were designed by using the SOLIDWORKS software program. Two standard or 2 mini implants in the canine region were embedded separately in the 3D assembled model. The base of the mandible was fixed, and vertical compressive loads of 100 N were applied unilaterally and bilaterally in the first molar region. The material properties for acrylic resin (denture), titanium (implants), mucosa (tissue), and bone (mandible) were allocated. Maximum von Mises stress and strain values were obtained and analyzed.
RESULTS: Maximum stresses of 9.78 MPa (bilaterally) and 11.98 MPa (unilaterally) were observed in 2 mini implants as compared with 3.12 MPa (bilaterally) and 3.81 MPa (unilaterally) in 2 standard implants. The stress values in the mandible were observed to be almost double the mini implants as compared with the standard implants. The stresses in the denture were in the range of 3.21 MPa and 3.83 MPa and in the mucosa of 0.68 MPa and 0.7 MPa for 2 implants under unilateral and bilateral loading conditions. The strain values shown similar trends with both implant types under bilateral and unilateral loading.
CONCLUSIONS: Two mini implants generated an average of 68.15% more stress than standard implants. The 2 standard implant-retained overdenture showed less stress concentration in and around implants than mini implant-retained overdentures.
PURPOSE: The purpose of this in vitro study was to determine the wetting properties of 3 different commercially available denture base resin materials with artificial salivary substitute by using contact angle measurements and to compare these properties before and after thermocycling.
MATERIAL AND METHODS: A total 120 specimens were fabricated with 3 different denture base materials (n=40): heat-polymerized polymethylmethacrylate (DenTek), injection-molded nylon polyamide (Valplast), and microwave polymerized (VIPI WAVE). The advancing and receding contact angles were measured with a goniometer by using the WinDrop++ software program. The contact angle hysteresis was calculated from the advancing and receding contact angles values. The same specimens were subjected to thermocycling to measure the advancing and receding contact angles values. The comparative evaluation was carried out before and after thermocycling.
RESULTS: The mean ±standard deviation contact angles of the microwave-polymerized material were (62.40 ±1.21 degrees) advancing contact angle, (32.12 ±0.66 degrees) receding contact angle, and (30.28 ±1.40 degrees) contact angle of hysteresis. It was followed by the injection-molded nylon polyamide material, whose mean ±standard deviation contact angle values were (68.57 ±1.72 degrees) advancing contact angle, (43.02 ±1.39 degrees) receding contact angle, (26.27 ±2.05 degrees) contact angle hysteresis and high impact strength heat-polymerized polymethylmethacrylate material, whose mean ±standard deviation contact angle values were (69.81 ±0.16 degrees) advancing contact angle, (41.90 ±1.02 degrees) receding contact angle, and (27.91 ±0.97 degrees) contact angle hysteresis. The statistical analysis showed significant differences among contact angle values of the microwave-polymerized material as compared with the heat-polymerized polymethylmethacrylate and injection-molded nylon polyamide materials (P
STUDY DESIGN: In total, 282 patients with oral submucous fibrosis were treated with topical corticosteroid and oral antioxidant and the ice-cream stick exercise regimen. Patients in subgroups A1, A2, and A3 were additionally given a new MED. Patients in subgroups A1 and B1 patients with interincisal distance (IID) of 20 to 35 mm were managed without any additional therapy; patients in subgroups A2 and B2 with IID of 20 to 35 mm were additionally managed with intralesional injections; and those in subgroups A3 and B3 with IID less than 20 mm were managed surgically. Subjective evaluation of decrease in the oral mucosal burning was measured on a visual analogue scale (VAS). Analysis of variance and Tukey's multiple post hoc analysis were carried out to present the results.
RESULTS: Patients using the MED, that is, subgroups A1, A2, and A3, showed reduction in burning sensation in the range of 64.8% to 71.1% and 27.8% to 30.9%, whereas in subgroups B1, B2, and B3, reduction in burning sensation ranged from 64.7% to 69.9% and from 29.3% to 38.6% after 6 months. The wo-way analysis of variance indicated statistically significant results in changes in initial VAS scores to 6-monthly VAS scores between MED users and non-MED users.
CONCLUSIONS: The MED helps to enhance the rate of reduction of mucosal burning sensation, in addition to the conventional ice-cream stick regimen, as an adjunct to local and surgical treatment.
PURPOSE: The purpose of this in vitro study was to evaluate the wettability of 3 different artificial saliva substitutes on heat-polymerized acrylic resin and to compare these properties with natural saliva and distilled water.
MATERIAL AND METHODS: A total of 150 heat-polymerized acrylic resin specimens were prepared with 25×15×2 mm dimensions. The specimens were divided into 5 groups (n=30): human saliva, distilled water, Aqwet, Mouth Kote, and Stoppers 4. The advancing and receding contact angle values were measured by using a goniometer, and the contact angle hysteresis and equilibrium angle were calculated. One-way ANOVA and the Bonferroni multiple comparisons test were performed to determine the difference between contact angle values among the groups (α=.05).
RESULTS: The means of the 5 groups differed significantly (P
Materials and Methods: A total of 100 CBCT-Digital Imaging and Communications in Medicine files of the patients of 3 ethnic populations (Malay, Chinese and Indian) between the ages of 18 and 80 years were selected for the study. The files were imported onto the iCAT software. The measurements of the SIDIAN to the lower border of the mandible in molar regions were done on both sides. The data was analysed using t-test, one-way analysis of variance test, and correlation coefficient test via the SPSS software.
Results: Statistically significant positive correlations were identified between the SIDIAN from the lower border of the mandible in the first and second molar regions within the same side as well as between both sides of the mandible (r ≈ 0.8). There were no statistically significant differences between genders. However, there were statistically significant differences on both molar regions and on both sides in all three ethnic groups (P < 0.05). In general, the SIDIAN from the lower border of the mandible was greatest amongst Chinese and smallest amongst Indians.
Conclusions: The strong positive correlations on both sides of the mandible indicate the presence of symmetry. Ethnicity-related variations exist in terms of the location of the IAN in the mandible.
BACKGROUND: Literature lacks information on various unsplinted attachment systems and their effect on peri-implant tissue health. A focus question (as per PICOS) was set as follows: Does one particular unsplinted attachment system (I) compared with another (C) results in better peri-implant outcomes (O) in two implant-retained mandibular overdentures (P) using randomized controlled trials (RCTs) (S)? The literature search was conducted in the PubMed, MEDLINE and Cochrane Central Register of Controlled Trials (CENTRAL) databases between January 2011 and December 2021. The keywords used were "denture, overlay," "denture," "overlay" AND "dental prosthesis, implant supported," "dental implants," "dental implant abutment design" AND "jaw, edentulous," "mouth, edentulous" AND "mandible." Only RCTs on two implant-retained mandibular overdentures using unsplinted attachment systems measuring peri-implant tissue outcomes with minimum 1-year follow-up were selected. In total, 224 studies were identified in initial search, and 25 were shortlisted for full-text evaluation. Four studies were included for systematic review upon considering inclusion and exclusion criteria. The risk of bias was evaluated using Cochrane Risk of Bias Tool 2.0 (RoB 2.0).
REVIEW RESULTS: A total of 41 patients received ball attachments (in 3 studies), 36 patients received low-profile attachments (in 3 studies), 16 patients received magnet attachments (in 1 study), and 13 patients received telescopic attachments (in 1 study). All four studies used standard sized implants, however, differed in implant manufacturers. Two studies which compared ball attachments low-profile attachments revealed-similar peri-implant tissue health parameters but differed in crestal bone-level changes. One study compared ball with telescopic attachments and revealed similar results in crestal bone-level changes and all four peri-implant tissue health parameters. Single study compared magnets with low-profile attachments and shown lesser bone loss with magnet attachments. Single study was judged to have low risk of bias, single with some concerns, and remaining two to have high risk of bias.
CONCLUSION: Gingival index and bleeding index of the patients were not influenced by any of the unsplinted overdenture attachment (stud, magnet, telescopic) system. Inconclusive results found among the studies evaluated comparing crestal bone loss and plaque index.
CLINICAL SIGNIFICANCE: This review manuscript has simplified comparative analysis of different unsplinted attachment systems used in two implant mandibular overdentures to help clinicians choose correct system in such situation.
MATERIALS AND METHODS: In this within-subject crossover randomized clinical trial, total 20 edentulous patients were given conventional complete dentures for 3 months to use. All completed a satisfaction questionnaire before implant placement. They were randomly assigned to receive an overdenture retained by either ball or bar attachment. After 3 months satisfaction questionnaires were repeated, and crossover was done by changing the attachments. After use of 3 months of alternate attachments, patients were asked to complete the final questionnaires and asked to choose their preferred type. The patient satisfaction scores were recorded after using 3 months of conventional complete denture, 3 months of first attachment and 3 months of second attachment. Data were analyzed using Wilcoxon signed rank test. The P values were adjusted using Bonferroni multiple testing correction, and P
PURPOSE: The purpose of this study was to determine esthetic perceptions of the Malaysian population regarding the width of buccal corridor spaces and their effect on smile esthetics in individuals with short, normal, and long faces.
MATERIAL AND METHODS: The image of a smiling individual with a mesofacial face was modified to create 2 different facial types (brachyfacial and dolicofacial). Each face form was further modified into 5 different buccal corridors (2%, 10%, 15%, 22%, and 28%). The images were submitted to 3 different ethnic groups of evaluators (Chinese, Malay, Indian; 100 each), ranging between 17 and 21 years of age. A visual analog scale (50 mm in length) was used for assessment. The scores given to each image were compared with the Kruskal-Wallis test, and pairwise comparison was performed using the Mann-Whitney U test (α=.05).
RESULTS: All 3 groups of evaluators could distinguish gradations of dark spaces in the buccal corridor at 2%, 10%, and 28%. Statistically significant differences were observed among 3 groups of evaluators in esthetic perception when pairwise comparisons were performed. A 15% buccal corridor was found to score esthetically equally within 3 face types by all 3 groups of evaluators. The Indian population was more critical in evaluation than the Chinese or Malay populations. In a pairwise comparison, more significant differences were found between long and short faces and the normal face; the normal face was compared with long and short faces separately.
CONCLUSIONS: The width of the buccal corridor space influences smile attractiveness in different facial types. A medium buccal corridor (15%) is the esthetic characteristic preferred by all groups of evaluators in short, normal, and long face types.
PURPOSE: The purpose of this finite element analysis study was to evaluate stress and strain distribution patterns in 2-implant mandibular overdentures with different positions and angulations of implants under unilateral and bilateral loading.
MATERIAL AND METHODS: A cone beam computed tomography (CBCT)-based, 3-dimensional (3D) model of the mandible and an intraoral scanning-based 3D model of the denture were developed in the Mimics software program. A 3D model of a standard-sized implant with a low-profile overdenture attachment (LOCATOR) was developed in the Solidworks software program. Two implants were inserted in the 3D model of the mandible, with implants placed at different positions, 5, 10, 15, and 20 mm from the midline, and different distal angulations, 0-5, 0-10, 0-15, 5-5, 10-10, and 15-15 degrees (at 10-mm distance), in the 3Matics software program. Unilateral and bilateral vertical loads of 100 N were applied on the first molars in the ANSYS software program to record maximum von Mises stresses and strain values.
RESULTS: The stresses in the implants were maximum when placed at a 20-mm distance (4.18 MPa under unilateral and 4.2 MPa under bilateral loading), while for the implants placed at 5 mm, 10 mm, and 15 mm, the indicated stresses were less than 2.46 MPa following an increasing trend with an increase in the distance. The stresses in the implants were maximum when placed at 15-15-degree angulations (0.93 under unilateral and 0.92 MPa under bilateral loading). For lower angulations, the stresses on the implants ranged from 0.05 to 0.87 MPa. No specific trend was observed in stresses and strains with 0-5-, 0-10-, and 0-15-degree angulations, but an increasing trend was observed with 5-5-, 10-10-, and 15-15-degree angulations under unilateral loading. Under bilateral loading, the stresses and strains on the implants and the mandible showed negligible variations across all 6 angulations.
CONCLUSIONS: The most posterior position of implants (20 mm) exhibited the highest stresses and strains on the implants and the mandible under both loading conditions. Implants placed with 15-15-degree angulations exhibited the highest stresses. Stresses and strains were similar in implants with lower angulations.
PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions.
MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05).
RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P