Displaying publications 21 - 30 of 30 in total

Abstract:
Sort:
  1. Rozaini MNH, Semail NF, Saad B, Kamaruzaman S, Abdullah WN, Rahim NA, et al.
    Talanta, 2019 Jul 01;199:522-531.
    PMID: 30952293 DOI: 10.1016/j.talanta.2019.02.096
    Molecularly imprinted silica gel (MISG) was incorporated through dispersion in agarose polymer matrix to form a mixed matrix membrane (MMM) and was applied for the determination of three sulfonamide antibiotic compounds (i.e. sulfamethoxazole (SMX), sulfamonomethoxine (SMM), and sulfadiazine (SDZ)) from environmental water samples. Several important microextraction conditions, such as type of desorption solvent, extraction time, amount of sorbent, sample volume, pH, and effect of desorption time, were comprehensively optimized. A preconcentration factors of ≥ 20 was achieved by the extraction of 12.5 mL of water samples using the developed method. This microextraction-HPLC method demonstrated good linearity (1-500 μg L-1) with a coefficient of determination (R2) of 0.9959-0.9999, low limits of detection (0.06-0.17 μg L-1) and limits of quantification (0.20-0.56 μg L-1), good analyte recoveries (80-96%), and acceptable relative standard deviations (< 10%) under the optimized conditions. The method is systematically compared to those reported in the literature.
  2. Nasir ANM, Yahaya N, Zain NNM, Lim V, Kamaruzaman S, Saad B, et al.
    Food Chem, 2019 Mar 15;276:458-466.
    PMID: 30409620 DOI: 10.1016/j.foodchem.2018.10.044
    Thiol-functionalized magnetic carbon nanotubes (TMCNTs) were employed as the sorbent in the magnetic micro-solid phase extraction (M-µ-SPE) of sulfonamide antibiotics (SAs) in water, milks and chicken meat products prior to high performance liquid chromatography-diode array detector (HPLC-DAD) analysis. The synthesized sorbent was characterized by several spectroscopic techniques. Optimum conditions were: 20 mg of TMCNTs at pH 4, 2 min extraction time, 10% addition of salt and 30 mL of sample volume. Under the optimized TMCNTs-M-µ-SPE and HPLC-DAD conditions, the method showed good linearity in the range of 0.1-500 µg L-1 (r2 ≥ 0.9950), low limits of detection (0.02-1.5 µg L-1), good analytes recovery (80.7-116.2%) and acceptable RSDs (0.3-7.7%, n = 15). The method was applied to tap water (1), milks (15) and commercial chicken meat products (35), SAs were detected in five chicken meat samples (3.0-25.7 µg L-1). The method is critically compared to those reported in the literature.
  3. Al Balawi AN, Yusof NA, Kamaruzaman S, Mohammad F, Wasoh H, Al Abbosh KF, et al.
    Biomed Res Int, 2019;2019:7064073.
    PMID: 30868072 DOI: 10.1155/2019/7064073
    The present study has synthesized poly(4,4'-cyclohexylidene bisphenol oxalate) by the condensation of oxalyl chloride with 4,4'-cyclohexylidene bisphenol, where its efficacy was tested for the solid-phase extraction of DNA. The synthesized polymer in the form of a white powder was characterized by FTIR, TGA-DTG, SEM, and BET analysis. The study utilized solid-phase application of the resulting polymer to extract DNA. The analysis of results provided the information that the extraction efficiency is a strong dependent of polymer amount and binding buffer type. Among the three types of buffers tested, the GuHCl buffer produced the most satisfactory results in terms of yield and efficiency of extraction. Moreover, the absorbance ratio of A260/A280 in all of the samples varied from 1.682 to 1.491, thereby confirming the capability of poly(4,4'-cyclohexylidene bisphenol oxalate) to elute pure DNA. The results demonstrated an increased DNA binding capacity with respect to increased percentage of the polymer. The study has concluded that poly(bisphenol Z oxalate) can be applied as one of the potential candidates for the high efficiency extraction of DNA by means of a simple, cost-effective, and environmentally friendly approach compared to the other traditional solid-phase methods.
  4. Subuhi NEAM, Saad SM, Zain NNM, Lim V, Miskam M, Kamaruzaman S, et al.
    J Sep Sci, 2020 Aug;43(16):3294-3303.
    PMID: 32519432 DOI: 10.1002/jssc.201901194
    In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption-based dispersive liquid-liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte-containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5-500 µg/L with a coefficient of determination of R2  = 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84-120%) and acceptable relative standard deviation (1.8-14.9%, n = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.
  5. Semail NF, Keyon ASA, Saad B, Kamaruzaman S, Zain NNM, Lim V, et al.
    J Chromatogr A, 2022 Dec 06;1685:463616.
    PMID: 36335907 DOI: 10.1016/j.chroma.2022.463616
    Realising the need to devise a simple, sensitive, and reliable detection method, this study investigated the development of a dual-stacking transient isotachophoresis (t-ITP) and sweeping in micellar electrokinetic chromatography with diode array detector (t-ITP/sweeping-MEKC-DAD) for the determination of selected non-steroidal anti-inflammatory drugs (NSAIDs); ketoprofen, diclofenac and naproxen from aqueous matrices. Prior to the system setup, various parameters were optimised to assess the potential use of the t-ITP paired with the sweeping stacking technique in micellar background electrolyte for dual preconcentration and separation of trace amounts of NSAIDs. Once the optimum conditions have been established, the method performance was validated and applied to 17 environmental water samples. Based on the results, the combined t-ITP and sweeping approach significantly improved the stacking and separation sensitivity. A large volume of samples could also be introduced and subsequently separated by MEKC with greater focusing effects due to the sweeping. Under optimised conditions, the developed method exhibited excellent linearity at a high range (0.1-500 ng/mL, r2 ≥ 0.998), low limits of detection (LODs) of 0.01-0.07 ng/mL, and a remarkable relative recovery (RR) of 99.6-101.9% with a relative standard deviation (RSD) of 1.4-8.6% (n = 9). Ultimately, the sensitivity enhancement factors improved up to 666-fold using the optimised method. Therefore, the proposed method presents a simplified yet effective and suitable for the determination of NSAIDs from aqueous matrices.
  6. Shaipulizan NS, Md Jamil SNA, Kamaruzaman S, Subri NNS, Adeyi AA, Abdullah AH, et al.
    Polymers (Basel), 2020 Feb 12;12(2).
    PMID: 32059354 DOI: 10.3390/polym12020423
    Ethylene glycol dimethacrylate (EGDMA) is used as a crosslinker in poly(acrylonitrile (AN)-co-vinylbenzyl chloride (VBC)) to investigate the effect of long-chain crosslinker to the porosity of the terpolymer system. Poly(AN-co-EGDMA-co-VBC) is synthesized by using precipitation polymerization method and further hypercrosslinked by Friedel-Crafts reaction. FT-IR spectra of poly(AN-co-EGDMA-co-VBC) show that the absorption bands at ~1290 cm-1 that are assigned to the C-Cl vibrations are almost disappeared in hypercrosslinked (HXL) poly(AN-co-EGDMA-co-VBC) polymers, confirming that the hypercrosslinking reaction is successful. SEM images show that the morphologies of the polymers are retained through the hypercrosslinking reactions. Brunauer-Emmett-Teller (BET) analysis shows that hypercrosslinked polymers had a specific surface area up to 59 m2·g-1. The preliminary performance of the terpolymer adsorbent to capture polar analyte is evaluated by adsorbing salicylic acid and mefenamic acid from aqueous solution in a batch system. The maximum adsorption capacity of salicylic acid and mefenamic acid were up to 416.7 mg·g-1 and 625 mg·g-1, respectively, and the adsorption kinetic data obeyed pseudo-second-order rate equation.
  7. Semail NF, Noordin SS, Keyon ASA, Waras MN, Saad B, Kamaruzaman S, et al.
    Biomed Chromatogr, 2021 May;35(5):e5050.
    PMID: 33314228 DOI: 10.1002/bmc.5050
    A simple and sensitive preconcentration strategy using sequential electrokinetic and hydrodynamic injection modes in micellar electrokinetic chromatography with diode array detection was developed and applied for the separation and determination of anticancer agent, 5-fluorouracil and its metabolite, 5-fluoro-2'-deoxyuridine, in human plasma. Sequential injection modes with increased analyte loading capacity using the anionic pseudo-stationary phase facilitated collection of the dispersed neutral and charged analytes into narrow zones and improved sensitivity. Several important parameters affecting sample enrichment performance were evaluated and optimized in this study. Under the optimized experimental conditions, 614- and 643-fold and 782- and 803-fold sensitivity improvement were obtained for 5-fluorouracil and its metabolite when compared with normal hydrodynamic and electrokinetic injection, respectively. The method has good linearity (1-1,000 ng/ml) with acceptable coefficient of determination (r2  > 0.993), low limits of detection (0.11-0.14 ng/ml) and satisfactory analyte relative recovery (97.4-99.7%) with relative standard deviations of 4.6-9.3% (n = 6). Validation results as well as the application to analysis of human plasma samples from cancer patients demonstrate the applicability of the proposed method to clinical studies.
  8. Abdul Bashid HA, Lim HN, Kamaruzaman S, Abdul Rashid S, Yunus R, Huang NM, et al.
    Nanoscale Res Lett, 2017 Dec;12(1):246.
    PMID: 28381070 DOI: 10.1186/s11671-017-2010-3
    A nanocomposite comprising of polypyrrole and reduced graphene oxide was electrodeposited onto a carbon bundle fibre (CBF) through a two-step approach (CBF/PPy-rGO-2). The CBF/PPy-rGO-2 had a highly porous structure compared to a nanocomposite of polypyrrole and reduced graphene oxide that was electrodeposited onto a CBF in a one-step approach (CBF/PPy-rGO), as observed through a field emission scanning electron microscope. An X-ray photoelectron spectroscopic analysis revealed the presence of hydrogen bond between the oxide functional groups of rGO and the amine groups of PPy in PPy-rGO-2 nanocomposite. The fabricated CBF/PPy-rGO-2 nanocomposite material was used as an electrode material in a symmetrical solid-state supercapacitor, and the device yielded a specific capacitance, energy density and power density of 96.16 F g(- 1), 13.35 Wh kg(- 1) and of 322.85 W kg(- 1), respectively. Moreover, the CBF/PPy-rGO-2 showed the capacitance retention of 71% after 500 consecutive charge/discharge cycles at a current density of 1 A g(- 1). The existence of a high degree of porosity in CBF/PPy-rGO-2 significantly improved the conductivity and facilitated the ionic penetration. The CBF/PPy-rGO-2-based symmetrical solid-state supercapacitor device demonstrated outstanding pliability because the cyclic voltammetric curves remained the same upon bending at various angles. Carbon bundle fibre modified with porous polypyrrole/reduced graphene oxide nanocomposite for flexible miniature solid-state supercapacitor.
  9. Saad SM, Aling NA, Miskam M, Saaid M, Mohamad Zain NN, Kamaruzaman S, et al.
    R Soc Open Sci, 2020 Apr;7(4):200143.
    PMID: 32431904 DOI: 10.1098/rsos.200143
    This work describes the development of a new methodology based on magnetic nanoparticles assisted dispersive liquid-liquid microextraction (DLLME-MNPs) for preconcentration and extraction of chloramphenicol (CAP) antibiotic residues in water. The approach is based on the use of decanoic acid as the extraction solvent followed by the application of MNPs to magnetically retrieve the extraction solvent containing the extracted CAP. The coated MNPs were then desorbed with methanol, and the clean extract was analysed using ultraviolet-visible spectrophotometry. Several important parameters, such as the amount of decanoic acid, extraction time, stirring rate, amount of MNPs, type of desorption solvent, salt addition and sample pH, were evaluated and optimized. Optimum parameters were as follows: amount of decanoic acid: 200 mg; extraction time: 10 min; stirring rate: 800 rpm; amount of MNPs: 60 mg; desorption solvent: methanol; salt: 10%; and sample pH, 8. Under the optimum conditions, the method demonstrated acceptable linearity (R2 = 0.9933) over a concentration range of 50-1000 µg l-1. Limit of detection and limit of quantification were 16.5 and 50.0 µg l-1, respectively. Good analyte recovery (91-92.7%) and acceptable precision with good relative standard deviations (0.45-6.29%, n = 3) were obtained. The method was successfully applied to tap water and lake water samples. The proposed method is rapid, simple, reliable and environmentally friendly for the detection of CAP.
  10. Semail NF, Abdul Keyon AS, Saad B, Kamaruzaman S, Mohamad Zain NN, Lim V, et al.
    Talanta, 2022 Jan 01;236:122833.
    PMID: 34635223 DOI: 10.1016/j.talanta.2021.122833
    A dynamic pH junction was used in capillary electrophoresis (CE-DAD) to on-line preconcentrate, separate, and determine trace amounts of sulfonamide antibiotics (SAs) in milk and yoghurt samples in this study. A sample matrix with 0.15% acetic acid and 10% methanol (MeOH) at a pH of 4.0, and a background electrolyte (BGE) that contained 35 mM sodium citrate with 10% MeOH at a pH of 8.5, and an acidic barrage of 0.4% acetic acid with 10% MeOH at a pH of 2.5 were utilised to achieve a stacking effect for SAs through a dynamic pH junction. Under optimised conditions, the proposed preconcentration method showed good linearity (30-500 ng/mL, r2 ≥ 0.9940), low limits of detection (LODs) of 4.1-6.3 ng/mL, and acceptable analytes recovery (81.2-106.9%) with relative standard deviations (RSDs) within 5.3-13.7 (n = 9). The limits of quantification (LOQs) were below the maximum residue limit approved by the European Union (EU) in this type of matrices. Sensitivity enhancement factors of up to 129 were reached with the optimised dynamic pH junction using CE with a diode array detector (DAD). The method was used to determine SAs in fresh milk, low-fat milk, full-cream milk, and yoghurt samples.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links