Displaying publications 181 - 200 of 1041 in total

Abstract:
Sort:
  1. Govindaraju R, Narayanan P
    N Engl J Med, 2016 Mar 31;374(13):e15.
    PMID: 27028934 DOI: 10.1056/NEJMicm1509943
    Matched MeSH terms: Carotid Sinus/radiography; Cavernous Sinus/radiography; Carotid-Cavernous Sinus Fistula/radiography*
  2. Wan Ahmad WS, Zaki WM, Ahmad Fauzi MF
    Biomed Eng Online, 2015;14:20.
    PMID: 25889188 DOI: 10.1186/s12938-015-0014-8
    Unsupervised lung segmentation method is one of the mandatory processes in order to develop a Content Based Medical Image Retrieval System (CBMIRS) of CXR. The purpose of the study is to present a robust solution for lung segmentation of standard and mobile chest radiographs using fully automated unsupervised method.
    Matched MeSH terms: Lung/radiography*; Radiography, Thoracic/instrumentation*
  3. Nabi G, Sadiq M
    Med J Malaysia, 2002 Mar;57(1):111-3.
    PMID: 14569728
    A 56-year-old man presented with lower urinary tract obstructive symptoms, hemoptysis and progressive dyspnoea. Digital rectal examination showed an enlarged nodular prostate and a tru-cut biopsy confirmed carcinoma prostate. Chest x-ray showed multiple bilateral cannon ball opacities suggestive of metastases. He underwent bilateral orchidectomy and follow up assessment showed significant clearing of the cannon-ball lesions in the lungs. He remained asymptomatic at follow up that has extended to 8 years.
    Matched MeSH terms: Carcinoma/radiography; Lung Neoplasms/radiography; Prostatic Neoplasms/radiography
  4. Saffor A, bin Ramli AR, Ng KH
    Australas Phys Eng Sci Med, 2003 Jun;26(2):39-44.
    PMID: 12956184
    Wavelet-based image coding algorithms (lossy and lossless) use a fixed perfect reconstruction filter-bank built into the algorithm for coding and decoding of images. However, no systematic study has been performed to evaluate the coding performance of wavelet filters on medical images. We evaluated the best types of filters suitable for medical images in providing low bit rate and low computational complexity. In this study a variety of wavelet filters are used to compress and decompress computed tomography (CT) brain and abdomen images. We applied two-dimensional wavelet decomposition, quantization and reconstruction using several families of filter banks to a set of CT images. Discreet Wavelet Transform (DWT), which provides efficient framework of multi-resolution frequency was used. Compression was accomplished by applying threshold values to the wavelet coefficients. The statistical indices such as mean square error (MSE), maximum absolute error (MAE) and peak signal-to-noise ratio (PSNR) were used to quantify the effect of wavelet compression of selected images. The code was written using the wavelet and image processing toolbox of the MATLAB (version 6.1). This results show that no specific wavelet filter performs uniformly better than others except for the case of Daubechies and bi-orthogonal filters which are the best among all. MAE values achieved by these filters were 5 x 10(-14) to 12 x 10(-14) for both CT brain and abdomen images at different decomposition levels. This indicated that using these filters a very small error (approximately 7 x 10(-14)) can be achieved between original and the filtered image. The PSNR values obtained were higher for the brain than the abdomen images. For both the lossy and lossless compression, the 'most appropriate' wavelet filter should be chosen adaptively depending on the statistical properties of the image being coded to achieve higher compression ratio.
    Matched MeSH terms: Brain/radiography*; Radiography, Abdominal/methods*
  5. Razif M, Lim HH
    Med J Malaysia, 2001 Jun;56 Suppl C:76-9.
    PMID: 11814256
    A 2 year-old Malay girl was admitted to our institution with a chesty cough and breathlessness but later found to have a chronic C1/C2 subluxation for one and half year with tetraplegia. Her cervical cord was decompressed and occipito-cervical fusion performed. Her neurological status improved significantly post-operatively and is able to care for her personal hygiene. The authors believe that the ability of the cervical cord to recover in the paediatric age group is remarkable that surgical option should be considered even when all seen lost. We believe that this is the first report in the literature to support this potential.
    Matched MeSH terms: Cervical Vertebrae/radiography; Dislocations/radiography; Quadriplegia/radiography
  6. Lim HH, Ong CH
    Med J Malaysia, 2001 Jun;56 Suppl C:41-5.
    PMID: 11814248
    The Pedriolle torsion meter is an established method of vertebral rotation assessment in scoliosis. However, the assessment of scoliosis by this method is static and indirect. The objective of this study is to compare the accuracy of a direct method of assessing scoliosis rotation by fluoroscopy compared to the Pedriolle torsion meter. Secondly, to determine that vertebral body rotation changes with supine posture compared to erect position. Eight volunteers with idiopathic scoliosis were assessed for the apical vertebral rotation with this method and the Pedriolle torsion meter. These patients were also assessed in the supine and erect position with the fluoroscopic method to determine if the apical vertebral rotation would change with posture. The mean Cobb angle of the curves was 62.8 degrees (range 45 degrees to 86 degrees). The mean apical vertebral rotation in a standing position was assessed to be 21.5 degrees by Pedriolle torsion meter and 29 degrees by the fluoroscopic method. This difference was not statistically significant by the student t-test. In most patient, the rotation of vertebrae improved by a varying degree ranging from none to 24 degrees in the supine position. In conclusion, the fluoroscopic method is an alternate mean of measuring vertebrae rotation in idiopathic scoliosis, with comparable accuracy to the Pedriolle torsion meter method. The amount of vertebral rotation changes with posture of the patient.
    Matched MeSH terms: Scoliosis/radiography*; Spine/radiography*; Torsion Abnormality/radiography
  7. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2001 Jun;56 Suppl C:73-5.
    PMID: 11814255
    A case of late reconstruction of the patellar tendon is reported. Besides partial loss of the tendon, the patient also had loss of the distal third of the patella. A rolled strip of fascia lata was used to reconstruct the tendon with tunnels through the patella. At the tenth month of follow-up, the result was deemed successful.
    Matched MeSH terms: Patella/radiography; Tendon Injuries/radiography; Fractures, Bone/radiography
  8. Chan PWK, DeBruyne JA, Goh AYT, Muridan R
    Med J Malaysia, 1999 Dec;54(4):520-2.
    PMID: 11072474
    Swyer-James-MacLeod syndrome is a rare complication of respiratory tract infection occurring in early childhood. We report two children with chronic cough and recurrent wheezing who fulfilled the diagnostic criteria for this disorder: 1) Unilateral loss of lung volume with hyperlucency on chest x-ray. 2) Unilateral reduction in vascularity on CT scan of the chest. 3) Unilateral loss of perfusion on Technetium 99c lung scan.
    Matched MeSH terms: Lung/radiography; Radiography, Thoracic; Lung, Hyperlucent/radiography
  9. Liam CK, Yap BH, Lam SK
    J Trop Med Hyg, 1993 Jun;96(3):197-200.
    PMID: 8505777
    A 17-year-old girl was admitted to hospital with dengue fever. On the ninth day of fever she developed haemoptysis and chest X-ray changes consistent with haemorrhage in her lungs. Thrombocytopaenia and mild coagulopathy were the most likely cause of this unusual haemoptysis in this patient. Investigations excluded other causes for the haemoptysis.
    Matched MeSH terms: Hemorrhage/radiography; Lung/radiography; Lung Diseases/radiography
  10. Sim PH, Razack AH, Pathmanathan R, Jalleh RP
    Med J Malaysia, 1995 Jun;50(2):189-91.
    PMID: 7565195
    Malignant fibrous histiocytoma is a mesenchymal tumour which can involve the genitourinary organs primarily or by secondary extension. Both conditions are rare. We report four cases of retroperitoneal malignant fibrous histiocytoma involving the kidney by local extension. Diagnosis was difficult because of diverse, non-specific clinical features and may only be reached at operation or post mortem. Prognosis is poor. Although en bloc tumour resection with nephrectomy was possible in two patients, they returned with recurrences.
    Matched MeSH terms: Kidney/radiography*; Retroperitoneal Neoplasms/radiography*; Histiocytoma, Benign Fibrous/radiography*
  11. Ding PH, Wong TJ
    Med J Malaysia, 1994 Sep;49(3):306-9.
    PMID: 7845288
    Two cases of leiomyomas of the jejunum presenting with gastrointestinal bleeding of uncertain origin are described. Diagnosis was finally established by selective angiography. Laparotomy and resection of the tumour were successfully performed. The approach and management of this rare tumour are outlined.
    Matched MeSH terms: Gastrointestinal Hemorrhage/radiography*; Jejunal Neoplasms/radiography*; Leiomyoma/radiography*
  12. Lei CC, Khairullah A, Zulfiqar A, Samad AS
    Med J Malaysia, 1992 Dec;47(4):320-2.
    PMID: 1303487
    This case report illustrates how a life-threatening renal bleeding which has failed to be controlled by open surgery can be elegantly managed by a minimally invasive technique of interventional radiology. It also allows maximal conservation of renal tissue so that the patient can avoid chronic dialysis or renal transplantation.
    Matched MeSH terms: Hemorrhage/radiography*; Kidney/radiography; Kidney Diseases/radiography*
  13. Noda A
    Trop Gastroenterol, 1991 Jan-Mar;12(1):3-14.
    PMID: 2058008
    It has been known that intrahepatic biliary lithiasis (IHBL) is prevalent in East Asia including Japan, South Korea, Taiwan, Malaysia, Hong Kong, and Singapore. In contrast, the entity has drawn little attention in Europe and the United States where only scattered reports appear. IHBL can be placed in the category of the benign disease. Its distinctive clinical picture is an intractable course necessitating multiple surgical interventions because recurrence is usual, rather than exceptional. This is in distinct contrast to ordinal stones which originate in the gallbladder. Patients with IHBL do not rarely die of progressive hepatic damage resulting from longstanding obstructive jaundice, cholangitis, liver abscess, septicemia, and so forth.
    Matched MeSH terms: Bile Duct Diseases/radiography; Bile Ducts, Intrahepatic/radiography; Cholelithiasis/radiography
  14. Fan CJ, Veerapen RJ, Tan CT
    Clin Radiol, 1989 Jan;40(1):91-4.
    PMID: 2646063
    A case is described of subdural spinal lipoma with posterior fossa extension and the world literature is reviewed. A high proportion of high cervical lipomas extend into the posterior cranial fossa. Many cases were probably missed in the pre-computed tomography era. Those cases with posterior fossa growth are more likely to be found in infants or those cases with symptoms dating from birth; most present with quadriparesis. All cases of high cervical lipoma demonstrated by myelography should be submitted to brain computed tomography in order to exclude posterior fossa extension and demonstrate the presence of hydrocephalus.
    Matched MeSH terms: Radiography
  15. Hussein NN
    Singapore Dent J, 1985 Jul;10(1):13-5.
    PMID: 3868814
    Matched MeSH terms: Tooth, Impacted/radiography; Tooth, Supernumerary/radiography; Tooth, Unerupted/radiography
  16. Baharuddin M, Sharaf I
    Med J Malaysia, 2001 Dec;56 Suppl D:54-6.
    PMID: 14569768
    We report a rare case of an acute haematogenous osteomyelitis of the femur in a five-year-old boy following a closed fracture of the femur. Because of its rare occurrence, the diagnosis of osteomyelitis was missed initially. He presented with a groin abscess seven weeks after injury. He was treated with external fixation, repeated debridements and intravenous antibiotics. Culture grew Staphylococcus aureus. The latest follow-up one-year after the injury showed resolution of the infection and union of the fracture. The range of knee movement is limited from 0-90 degrees due to quadriceps contracture.
    Matched MeSH terms: Femoral Fractures/radiography; Fractures, Closed/radiography; Osteomyelitis/radiography
  17. Skene-Smith H
    Br J Radiol, 1975 Aug;48(572):646-8.
    PMID: 810200
    Twenty-two cases of corrosive oesophageal strictures were reviewed and divided into annular, short segment and long segment lesions. The lower third of the oeseophagus was involved in all the long segment strictures, but with sparing of the extreme distal portion in most. Irregularity of the stricture walls with an appearance similar to reported cases of intramural diverticulosis is a common finding but smooth strictures can also occur.
    Matched MeSH terms: Burns, Chemical/radiography*; Diverticulum/radiography; Esophageal Stenosis/radiography*
  18. Anizaim AH, Zainuri DA, Zaini MF, Razak IA, Bakhtiar H, Arshad S
    PLoS One, 2020;15(11):e0241113.
    PMID: 33147247 DOI: 10.1371/journal.pone.0241113
    Two organometallic compounds known as (E)-1-ferrocenyl-(3-fluorophenyl)prop-2-en-1-one (Fc1) and (E)-1-ferrocenyl-(3-fluoro-4-methoxyphenyl)prop-2-en-1-one (Fc2) are designed and synthesized for application in dye-sensitized solar cell (DSSC) based on a donor-π-acceptor (D-π-A) architecture. By strategically introducing a methoxy group into the acceptor side of the compound, Fc2 which has adopted a D-π-A-AD structure are compared with the basic D-π-A structure of Fc1. Both compounds were characterized by utilizing the IR, NMR and UV-Vis methods. Target compounds were further investigated by X-ray analysis and studied computationally using Density Functional Theory (DFT) and Time-Dependent DFT (TD-DFT) approaches to explore their potential performances in DSSCs. An additional methoxy group has been proven in enhancing intramolecular charge transfer (ICT) by improving the planarity of Fc2 backbone. This good electronic communication leads to higher HOMO energy level, larger dipole moment and better short-circuit current density (Jsc) values. Eventually, the presence of methoxy group in Fc2 has improved the conversion efficiency as in comparison to Fc1 under the same conditions.
    Matched MeSH terms: Radiography
  19. Abdul Sani SF, Othman MHU, Alqahtani A, Almugren KS, Alkallas FH, Bradley DA
    PLoS One, 2020;15(12):e0241550.
    PMID: 33378398 DOI: 10.1371/journal.pone.0241550
    For x- and gamma- irradiations delivering entrance doses from 2- up to 1000 Gy to commercial 1.0 mm thick borosilicate glass microscope slides, study has been made of their thermoluminescence yield. With an effective atomic number of 10.6 (approximating bone equivalence), photon energy dependency is apparent in the low x-ray energy range, with interplay between the photoelectric effect and attenuation. As an example, over the examined dose range, at 120 kVp the photon sensitivity has been found to be some 5× that of 60Co gamma irradiations, also with repeatability to within ~1%. The glow-curves, taking the form of a single prominent broad peak, have been deconvolved yielding at best fit a total of five peaks, the associated activation energies and frequency factors also being obtained. The results indicate borosilicate glass slides to offer promising performance as a low-cost passive radiation dosimeter, with utility for both radiotherapy and industrial applications.
    Matched MeSH terms: Radiography
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links