Displaying all 3 publications

Abstract:
Sort:
  1. Rosenthal VD, Maki DG, Mehta Y, Leblebicioglu H, Memish ZA, Al-Mousa HH, et al.
    Am J Infect Control, 2014 09;42(9):942-56.
    PMID: 25179325 DOI: 10.1016/j.ajic.2014.05.029
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line-associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN.
    Matched MeSH terms: Infection Control/statistics & numerical data*
  2. Katherason SG, Naing L, Jaalam K, Nik Mohamad NA, Bhojwani K, Harussani ND, et al.
    J Infect Dev Ctries, 2010 Mar 08;4(2):118-23.
    PMID: 20212345
    BACKGROUND: Hand decontamination is a critical infection control practice in the prevention of nosocomial infection. This study was conducted to observe the hand hygiene practices of nurses and doctors in two intensive care units (ICUs) in Malaysia.

    METHODOLOGY: Staff members were observed during patient contacts, and their hand washing techniques and hand hygiene practices were monitored. Five contact periods were observed for staff members while they cared for their assigned patients. Hand hygiene practices before and after patient contacts were categorized as clean uncontaminated, clean recontaminated, new gloves, and unchanged contaminated gloves. Compliance to hand-washing steps and time taken for hand washing were analyzed. Appropriate use of gloves based on CDC criteria also was assessed.

    RESULTS: Compliance to hand hygiene practices was 70% before each patient contact. Staff members did not completely adhere to the hand-washing steps. The average time taken to wash hands was 20 seconds, and the necessary steps (rubbing palm over dorsum; rubbing fingers interlaced, and rotational rubbing of thumbs) were practiced minimally by all staff. Hand washing protocol was generally followed by all staff (100%). Alcohol hand rubs were available but were used moderately (60%); when used, staff members did not wait for the alcohol to dry. Only 4% of staff changed contaminated gloves between patients.

    CONCLUSIONS: Hand hygiene compliance by ICU staff members needs to be improved. Improving adherence to correct hand hygiene techniques will require effective education programs and behavioral modification techniques. Moreover, hand hygiene guidelines must be incorporated into new staff orientation programs and the continuing education curriculum in the two hospitals studied.

    Matched MeSH terms: Infection Control/statistics & numerical data*
  3. Lee YF, McLaws ML, Ong LM, Amir Husin S, Chua HH, Wong SY, et al.
    PMID: 31798841 DOI: 10.1186/s13756-019-0644-x
    Background: Hand hygiene compliance can be improved by strategies fostering collaborative efforts among healthcare workers (HCWs) through change agents. However, there is limited information about how change agents shape the social networks of work teams, and how this relates to organisational culture. The objectives of this study were to describe the influence of peer-identified change agents (PICAs) and management-selected change agents (MSCAs) on hand hygiene, perception of their leadership style by peers, and the role of the organisational culture in the process of hand hygiene promotion.

    Methods: This study, stratified in pre-, during, and post-intervention periods, was conducted between February 2017 and March 2018 in two wards at a tertiary care hospital in Malaysia. Hand hygiene promotion was facilitated either by PICAs (study arm 1) or MSCAs (study arm 2), and the two wards were randomly allocated to one of the two interventions. Outcomes were: 1) perceived leadership styles of PICAs and MSCAs by staff, vocalised during question and answer sessions; 2) the social network connectedness and communication patterns between HCWs and change agents by applying social network analysis; and 3) hand hygiene leadership attributes obtained from HCWs in the post-intervention period by questionnaires.

    Results: Hand hygiene compliance in study arm 1 and study arm 2 improved by from 48% (95% CI: 44-53%) to 66% (63-69%), and from 50% (44-55%) to 65% (60-69%), respectively. There was no significant difference between the two arms. Healthcare workers perceived that PICAs lead by example, while MSCAs applied an authoritarian top-down leadership style. The organisational culture of both wards was hierarchical, with little social interaction, but strong team cohesion. Position and networks of both PICAs and MSCAs were similar and generally weaker compared to the leaders who were nominated by HCWs in the post-intervention period. Healthcare workers on both wards perceived authoritative leadership to be the most desirable attribute for hand hygiene improvement.

    Conclusion: Despite experiencing successful hand hygiene improvement from PICAs, HCWs expressed a preference for the existing top-down leadership structure. This highlights the limits of applying leadership models that are not supported by the local organisational culture.

    Matched MeSH terms: Infection Control/statistics & numerical data*