Displaying all 2 publications

Abstract:
Sort:
  1. Kamaruddin AH, Uzir MH, Aboul-Enein HY, Halim HN
    Chirality, 2009 Apr;21(4):449-67.
    PMID: 18655180 DOI: 10.1002/chir.20619
    This review tracks a decade of dynamic kinetic resolution developments with a biocatalytic inclination using enzymatic/microbial means for the resolution part followed by the racemization reactions either by means of enzymatic or chemocatalyst. These fast developments are due to the ability of the biocatalysts to significantly reduce the number of synthetic steps which are common for conventional synthesis. Future developments in novel reactions and products of dynamic kinetic resolutions should consider factors that are needed to be extracted at the early synthetic stage to avoid inhibition at scale-up stage have been highlighted.
    Matched MeSH terms: Fenoprofen/chemistry
  2. Syed Yaacob SFF, Mohd Jamil AK, Kamboh MA, Wan Ibrahim WA, Mohamad S
    PeerJ, 2018;6:e5108.
    PMID: 30002963 DOI: 10.7717/peerj.5108
    Calixarene framework functionalized bio-polymeric magnetic composites (MSp-TDI-calix) were synthesized and utilized as magnetic solid-phase extraction (MSPE) sorbent for the extraction of non-steroidal anti-inflammatory drugs (NSAIDs), namely indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP), from environmental water samples. MSp-TDI-calix was characterized by FT-IR, XRD, FESEM, EDX, VSM and BET analysis, and the results were compared with Sp-TDI and Sp-TDI-calix. To maximize the extraction performance of MSp-TDI-calix decisive MSPE affective parameters such as sorbent amount, extraction time, sample volume, type of organic eluent, volume of organic eluent, desorption time and pH were comprehensively optimized prior to HPLC-DAD determination. The analytical validity of the proposed MSPE method was evaluated under optimized conditions and the following figures of merit were acquired: linearity with good determination coefficient (R2 ≥ 0.991) over the concentration range of 0.5-500 µg/L, limits of detection (LODs) ranged from 0.06-0.26 µg/L and limits of quantitation (LOQ) between 0.20-0.89 µg/L. Excellent reproducibility and repeatability under harsh environment with inter-day and intra-day relative standard deviations were obtained in the range of 2.5-3.2% and 2.4-3.9% respectively. The proposed method was successfully applied for analysis of NSAIDs in tap water, drinking water and river water with recovery efficiency ranging from 88.1-115.8% with %RSD of 1.6-4.6%.
    Matched MeSH terms: Fenoprofen
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links