Displaying all 3 publications

Abstract:
Sort:
  1. Omar R, Herse P
    Clin Exp Optom, 2004 Nov;87(6):386-9.
    PMID: 15575812 DOI: 10.1111/j.1444-0938.2004.tb03099.x
    PURPOSE: Non-linear regression analysis was used to determine dark adaptation indices in people with retinitis pigmentosa and in control subjects.
    METHODS: Dark adaptation data were collected for 13 people with retinitis pigmentosa and 21 controls using the Goldmann-Weekers Dark Adaptometer. Data were analysed using an exponential non-linear regression model and dark adaptation indices derived. The results were compared to age-related values.
    RESULTS: The mean cone threshold of the group with RP (4.73 +/- 0.19 log units) was significantly greater than that found in the control group (3.69 +/- 0.12 log units). The rate of cone dark adaptation in the RP group was not significantly different from that of the control group. The a break in the RP group (6.46 +/- 0.70 minutes) was delayed when compared to the control group (4.29 +/- 0.21 minutes) and the rate of rod dark adaptation in the RP group was slower (10 +/- 2 per cent per minute) than that of the control group (15 +/- 1 per cent per minute).
    CONCLUSIONS: This study has shown that a relatively simple data analysis can provide a more quantitative and intuitive description of dark adaptation rates in people with retinal disease. This technique will enable more effective use of dark adaptometry as a supplement to objective electrophysiology, when monitoring people with retinitis pigmentosa.
    Study site: Retinitis Pigmentosa Society of NSW, the National Foundation of Blind Citizens in New South Wales and the Low Vision Clinic of the School of Optometry University of NSW, Australia
    Matched MeSH terms: Differential Threshold
  2. Piccini JP, Stromberg K, Jackson KP, Laager V, Duray GZ, El-Chami M, et al.
    Heart Rhythm, 2017 05;14(5):685-691.
    PMID: 28111349 DOI: 10.1016/j.hrthm.2017.01.026
    BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.

    OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds.

    METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.

    RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.

    CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.

    Matched MeSH terms: Differential Threshold
  3. Dane AB, Teh E, Reckelhoff KE, Ying PK
    J Manipulative Physiol Ther, 2017 09;40(7):511-516.
    PMID: 29079256 DOI: 10.1016/j.jmpt.2017.06.011
    OBJECTIVES: The aim of this study was to investigate if there were differences in the two-point discrimination (2-PD) of fingers among students at different stages of a chiropractic program.

    METHODS: This study measured 2-PD thresholds for the dominant and nondominant index finger and dominant and nondominant forearm in groups of students in a 4-year chiropractic program at the International Medical University in Kuala Lumpur, Malaysia. Measurements were made using digital calipers mounted on a modified weighing scale. Group comparisons were made among students for each year of the program (years 1, 2, 3, and 4). Analysis of the 2-PD threshold for differences among the year groups was performed with analysis of variance.

    RESULTS: The mean 2-PD threshold of the index finger was higher in the students who were in the higher year groups. Dominant-hand mean values for year 1 were 2.93 ± 0.04 mm and 1.69 ± 0.02 mm in year 4. There were significant differences at finger sites (P < .05) among all year groups compared with year 1. There were no significant differences measured at the dominant forearm between any year groups (P = .08). The nondominant fingers of the year groups 1, 2, and 4 showed better 2-PD compared with the dominant finger. There was a significant difference (P = .005) between the nondominant (1.93 ± 1.15) and dominant (2.27 ± 1.14) fingers when all groups were combined (n = 104).

    CONCLUSIONS: The results of this study demonstrated that the finger 2-PD of the chiropractic students later in the program was more precise than that of students in the earlier program.

    Matched MeSH terms: Differential Threshold