Displaying all 3 publications

Abstract:
Sort:
  1. Na'imah S, Apsari R, Masruroh, Yasin M, Wadi Harun S
    Heliyon, 2024 Jun 30;10(12):e32349.
    PMID: 38975194 DOI: 10.1016/j.heliyon.2024.e32349
    A gold-coated Kretschmann setup has been constructed and explored as a surface plasmon resonance (SPR) platform, specifically tailored for the detection of low-concentration sodium chloride (NaCl) solutions. The setup employs a BK7 prism coated with a 50 nm gold layer, serving as a plasmonic layer, to induce resonance. This resonance arises from the interplay between light waves and free electrons propagating at the interface of two media. The experimental findings reveal a notable resonance angle shift of 10° when the NaCl concentration is varied from 0 to 2.5 %. Furthermore, angle interrogation provides insightful details about the sensor's response to changes in the refractive index, showcasing a commendable sensitivity of 2400°/RIU, a high level of linearity at 0.9771, and an impressive resolution of 0.217 %. The demonstrated capabilities of this sensor underscore its potential for widespread applications, particularly in the monitoring of salt concentration across diverse domains such as seawater analysis, food processing, and fermentation processes. The robust performance and precision of this proposed sensor position it as a valuable tool with promising prospects for addressing the needs of various industries dependent on accurate salt concentration measurements.
  2. Sadrolhosseini AR, Krishnan G, Shafie S, Abdul Rashid S, Wadi Harun S
    Molecules, 2020 Dec 09;25(24).
    PMID: 33316885 DOI: 10.3390/molecules25245798
    This study used the carbon dots solution for the laser ablation technique to fabricate silver nanoparticles. The ablation time range was from 5 min to 20 min. Analytical methods, including Fourier transform infrared spectroscopy (FTIR), UV-visible spectroscopy, transmission electron microscopy, and Raman spectroscopy were used to categorize the prepared samples. The UV-visible and z-scan techniques provided optical parameters such as linear and nonlinear refractive indices in the range of 1.56759 to 1.81288 and 7.3769 × 10-10 cm2 W-1 to 9.5269 × 10-10 cm2 W-1 and the nonlinear susceptibility was measured in the range of 5.46 × 10-8 to 6.97 × 10-8 esu. The thermal effusivity of prepared samples, which were measured using the photoacoustic technique, were in the range of 0.0941 W s1/2 cm-2 K-1 to 0.8491 W s1/2 cm-2 K-1. The interaction of the prepared sample with fluoride was investigated using a Raman spectrometer. Consequently, the intensity of the Raman signal decreased with the increasing concentration of fluoride, and the detection limit is about 0.1 ppm.
  3. Soboh RSM, Al-Masoodi AHH, Erman FNA, Al-Masoodi AHH, Nizamani B, Arof H, et al.
    Front Optoelectron, 2022 Jun 13;15(1):28.
    PMID: 36637608 DOI: 10.1007/s12200-022-00027-2
    A stable mode-locked laser was demonstrated using a newly developed zinc phthalocyanine (ZnPc) thin film as passive saturable absorber (SA) in ytterbium-doped fiber laser (YDFL). The ZnPc thin film was obtained using a casting method and then inserted between the two fiber ferrules of a YDFL ring cavity to generate mode-locked pulses. The resulting pulsed laser operated at a wavelength of 1034.5 nm having a repetition rate of 3.3 MHz. At pump power of 277 mW, the maximum output power and pulse energy are achieved at 4.92 mW and 1.36 nJ, respectively. ZnPc has a high chemical and photochemical stability, and its significance for use as a potential SA in a mode-locked laser is reported in this work.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links