Displaying all 2 publications

Abstract:
Sort:
  1. Syed Yaacob SFF, Mohd Jamil AK, Kamboh MA, Wan Ibrahim WA, Mohamad S
    PeerJ, 2018;6:e5108.
    PMID: 30002963 DOI: 10.7717/peerj.5108
    Calixarene framework functionalized bio-polymeric magnetic composites (MSp-TDI-calix) were synthesized and utilized as magnetic solid-phase extraction (MSPE) sorbent for the extraction of non-steroidal anti-inflammatory drugs (NSAIDs), namely indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP), from environmental water samples. MSp-TDI-calix was characterized by FT-IR, XRD, FESEM, EDX, VSM and BET analysis, and the results were compared with Sp-TDI and Sp-TDI-calix. To maximize the extraction performance of MSp-TDI-calix decisive MSPE affective parameters such as sorbent amount, extraction time, sample volume, type of organic eluent, volume of organic eluent, desorption time and pH were comprehensively optimized prior to HPLC-DAD determination. The analytical validity of the proposed MSPE method was evaluated under optimized conditions and the following figures of merit were acquired: linearity with good determination coefficient (R2 ≥ 0.991) over the concentration range of 0.5-500 µg/L, limits of detection (LODs) ranged from 0.06-0.26 µg/L and limits of quantitation (LOQ) between 0.20-0.89 µg/L. Excellent reproducibility and repeatability under harsh environment with inter-day and intra-day relative standard deviations were obtained in the range of 2.5-3.2% and 2.4-3.9% respectively. The proposed method was successfully applied for analysis of NSAIDs in tap water, drinking water and river water with recovery efficiency ranging from 88.1-115.8% with %RSD of 1.6-4.6%.
  2. Syed Yaacob SFF, Kamboh MA, Wan Ibrahim WA, Mohamad S
    R Soc Open Sci, 2018 Jul;5(7):171311.
    PMID: 30109037 DOI: 10.1098/rsos.171311
    A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized magnetic β-cyclodextrin functionalized with toluene diisocyanate (TDI) as a linker and further modified with bio-polymeric spores of sporopollenin (MSp-TDI-βCD), was developed for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs), namely, indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP) from water samples prior to their HPLC-DAD determination. The newly synthesized MSp-TDI-βCD was comprehensibly characterized using FT-IR, XRD, SEM-EDX, BET and VSM analyses. The separation of selected NSAIDs on MSp-TDI-βCD from aqueous solution was simply achieved by applying an external magnetic field via a permanent magnet. The MSPE parameters affecting extraction performance, i.e. sorbent dosage, sample volume, extraction and desorption time, type of organic eluent and volume and solution pH were investigated and optimized. The proposed method showed linear range between 0.5 and 500 ng ml-1, low limit of detection at S/N = 3 (0.16-0.37 ng ml-1) and limit of quantification at S/N = 10 (0.53-1.22 ng ml-1). The inter-day (n = 15) and intra-day (n = 5) precision for the proposed methods given by relative standard deviation (RSD%) was in the range of 2.5-4.0 and 2.1-5.5, respectively. The extraction recoveries of NSAIDs from environmental samples (tap, drinking and river water) ranged from 92.5% to 123.6%, with satisfactory precision (RSD% less than 12.4%).
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links