Displaying all 7 publications

Abstract:
Sort:
  1. Almasi D, Sadeghi M, Lau WJ, Roozbahani F, Iqbal N
    Mater Sci Eng C Mater Biol Appl, 2016 Jul 01;64:102-107.
    PMID: 27127033 DOI: 10.1016/j.msec.2016.03.053
    The present work reviews the current fabrication methods of the functionally graded polymeric material (FGPM) and introduces a novel fabrication method that is versatile in applications as compared to those of existing used methods. For the first time electrophoresis was used to control the distribution of the tetracycline hydrochloride (TC) in a film made of polylactic acid (PLA), aiming to induce antimicrobial effect on the film prepared. The elemental analysis on the film surface showed that by employing electrophoresis force, higher amount of TC was detected near the top surface of the film. Results also showed that the FGPM samples with higher percentage of the TC on the film surface were highly effective to minimize the growth of Escherichia coli. These findings are useful and important to improve dispersion quality of the particles in the composite material and further enhance its antibacterial property.
  2. Almasi D, Izman S, Sadeghi M, Iqbal N, Roozbahani F, Krishnamurithy G, et al.
    Int J Biomater, 2015;2015:475435.
    PMID: 25838826 DOI: 10.1155/2015/475435
    Polyether ether ketone (PEEK) is considered the best alternative material for titanium for spinal fusion cage implants due to its low elasticity modulus and radiolucent property. The main problem of PEEK is its bioinert properties. Coating with hydroxyapatite (HA) showed very good improvement in bioactivity of the PEEK implants. However the existing methods for deposition of HA have some disadvantages and damage the PEEK substrate. In our previous study a new method for deposition of HA on PEEK was presented. In this study cell proliferation of mesenchymal stem cell and apatite formation in simulated body fluid (SBF) tests were conducted to probe the effect of this new method in improvement of the bioactivity of PEEK. The mesenchymal stem cell proliferation result showed better cells proliferation on the treated layer in comparison with untreated PEEK. The apatite formation results showed the growth of the HA on the treated PEEK but there was not any sight of the growth of HA on the untreated PEEK even after 2 weeks. The results showed the new method of the HA deposition improved the bioactivity of the treated PEEK in comparison with the bare PEEK.
  3. Almasi D, Lau WJ, Rasaee S, Abbasi K
    J Biomed Mater Res B Appl Biomater, 2022 04;110(4):838-847.
    PMID: 34788503 DOI: 10.1002/jbm.b.34964
    The unique characteristics of polyether ether ketone (PEEK) including low elastic modulus, high mechanical strength, and biocompatibility have made it an attractive alternative for the metallic biomaterials. However, its bioinert property is always the main concern, which could lead to poor osseointegration and subsequent clinical failure of the implant. Changing the surface structure to porous structure and mixing it with bioactive hydroxyapatite (HA) are the common methods, which could be used to enhance the properties of the PEEK-based implants. In this study, friction stir processing was utilized for the fabrication of porous HA/PEEK surface nanocomposite. Scanning electron microscopic image of the nanocomposite surface showed nano-scale roughness of the porous structure. Water contact angle test confirmed the increase in the wettability of the treated specimens. In vitro bioactivity test via simulated body fluid solution, initial cell adhesion, cell proliferation, and cell differentiation assay also confirmed the enhancement in bioactivity of the treated surface in comparison to the bare PEEK. This surface modification method requires no special equipment and would not damage the heat-sensitive PEEK substrate due to the low temperature used during the fabrication process.
  4. Almasi D, Lau WJ, Rasaee S, Sharifi R, Mozaffari HR
    Prog Biomater, 2020 Jun;9(1-2):35-44.
    PMID: 32363497 DOI: 10.1007/s40204-020-00130-7
    There is increasing interest in the use of polyether ether ketone (PEEK) for orthopedic and dental implant applications due to its elastic modulus (close to that of bone), biocompatibility and radiolucent properties. However, PEEK is still categorized as bioinert owing to its low integration with surrounding tissues. Methods such as depositing hydroxyapatite (HA) onto the PEEK surface could increase its bioactivity. However, depositing HA without damaging the PEEK substrate is still required further investigation. Friction stir processing is a solid-state processing method that is widely used for composite substrate fabrication. In this study, a pinless tool was used to fabricate a HA/PEEK surface nanocomposite for orthopedic and dental applications. Microscopical images of the modified substrate confirmed homogenous distribution of the HA on the surface of the PEEK. The resultant HA/PEEK surface nanocomposites demonstrated improved surface hydrophilicity coupled with better apatite formation capacity (as shown in the simulated body fluid) in comparison to the pristine PEEK, making the newly developed material more suitable for biomedical application. This surface deposition method that is carried out at low temperature would not damage the PEEK substrate and thus could be a good alternative for existing commercial methods for PEEK surface modification.
  5. Almasi D, Iqbal N, Sadeghi M, Sudin I, Abdul Kadir MR, Kamarul T
    Int J Biomater, 2016;2016:8202653.
    PMID: 27127513 DOI: 10.1155/2016/8202653
    There is an increased interest in the use of polyether ether ketone (PEEK) for orthopedic and dental implant applications due to its elastic modulus close to that of bone, biocompatibility, and its radiolucent properties. However, PEEK is still categorized as bioinert due to its low integration with surrounding tissues. Many studies have reported on methods to increase the bioactivity of PEEK, but there is still one-preparation method for preparing bioactive PEEK implant where the produced implant with desirable mechanical and bioactivity properties is required. The aim of this review is to present the progress of the preparation methods for improvement of the bioactivity of PEEK and to discuss the strengths and weaknesses of the existing methods.
  6. Assadian M, Jafari H, Ghaffari Shahri SM, Idris MH, Almasi D
    Biomed Mater Eng, 2016 Aug 12;27(2-3):287-303.
    PMID: 27567782 DOI: 10.3233/BME-161585
    In this study, different types of calcium-phosphate phases were coated on NaOH pre-treated pure magnesium. The coating was applied by electrodeposition method in order to provide higher corrosion resistance and improve biocompatibility for magnesium. Thickness, surface morphology and topography of the coatings were analyzed using optical, scanning electron and atomic-force microscopies, respectively. Composition and chemical bonding, crystalline structures and wettability of the coatings were characterized using energy-dispersive and attenuated total reflectance-Fourier transform infrared spectroscopies, grazing incidence X-ray diffraction and contact angle measurement, respectively. Degradation behavior of the coated specimens was also investigated by potentiodynamic polarization and immersion tests. The experiments proved the presence of a porous coating dominated by dicalcium-phosphate dehydrate on the specimens. It was also verified that the developed hydroxyapatite was crystallized by alkali post-treatment. Addition of supplemental fluoride to the coating electrolyte resulted in stable and highly crystallized structures of fluoridated hydroxyapatite. The coatings were found effective to improve biocompatibility combined with corrosion resistance of the specimens. Noticeably, the fluoride supplemented layer was efficient in lowering corrosion rate and increasing surface roughness of the specimens compared to hydroxyapatite and dicalcium-phosphate dehydrates layers.
  7. Sharifi R, Almasi D, Sudin IB, Abdul Kadir MR, Jamshidy L, Amiri SM, et al.
    Int J Biomater, 2018;2018:9607195.
    PMID: 30154853 DOI: 10.1155/2018/9607195
    The mechanical properties of coated layers are one of the important factors for the long-term success of orthopeadic and dental implants. In this study, the mechanical properties of the porous coated layer were examined via scratch and nanoindentation tests. The effect of compression load on the porous coated layer of sulphonated poly ether ether ketone/Hydroxyapatite was studied to determine whether it changes its mechanical properties. The water contact angle and surface roughness of the compressed coated layer were also measured. The results showed a significant increase in elastic modulus, with mean values ranging from 0.464 GPa to 1.199 GPa (p<0.05). The average scratch hardness also increased significantly from 69.9 MPa to 95.7 MPa after compression, but the surface roughness and wettability decreased significantly (p<0.05). Simple compression enhanced the mechanical properties of the sulphonated poly ether ether ketone/hydroxyapatite coated layer, and the desired mechanical properties for orthopaedic and dental implant application can be achieved.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links