Displaying all 3 publications

Abstract:
Sort:
  1. Abdul Aziz, A., Abu Kasim, N.H., Ramasindarum, C., Mohamad Yusof, M.Y.P., Paiizi, M., Ahmad, R.
    Ann Dent, 2011;18(1):1-7.
    MyJurnal
    The aim of this study was to assess the wear of tungsten carbide burs and round rotary diamond instruments through measurements of rake angle and visual observations respectively under a field emission scanning electron microscope. Sixty short and long head pear-shaped tungsten carbide burs and 18 round rotary diamond instruments that had been used to complete < 5, > 5 and > 10 cavity preparations (n=10/group) were selected from the 3rd and 4th year dental students, Faculty of Dentistry, University of Malaya. There were two control groups consisting of long and short tungsten carbide burs of ten each. Two-way ANOVA was used to analyse the rake angle data. The data from the two control groups were collectively analysed following multiple paired t-test (p>.05) which showed no significant difference between the two types of tungsten carbide bur (short and long head). The mean rake angle of the control group was significantly higher (p < .05) compared to the < 5, > 5 and > 10 cavity preparation groups. The rake angle of the > 10 cavity preparation group was significantly lower than the other two test groups (p < .05). Round rotary diamond instruments in the < 5 cavity preparation group showed intact diamond particles with distinct cutting facets comparable to the control group. However, diamonds instruments in the > 5 and > 10 cavity preparation groups showed blunt diamond particles. In conclusion, wear of tungsten carbide burs and round rotary diamond instruments were evident after repeated use. Wear was more pronounced when instruments were used to prepare more than ten cavities.
  2. Yahya, N.A., Lui, J.L., Chong, K.W.A., Abu Kasim, N.H., Radzi, Z., Lim, C.M.
    Ann Dent, 2008;15(1):11-19.
    MyJurnal
    The objective of this study was to investigate the effect of various luting cement systems on bond strength of fibre-reinforced posts to root canal dentine. 40 extracted single rooted sound premolar teeth were root filled, decoronated and randomly divided into four groups. Fibre posts, Aestheti- Plus™ (Bisco,Inc. Schaumburg, IL, USA) were cemented using four luting cements: Group A (control): Elite 100® Zinc phosphate (GC Corp, Japan), Group B: Calibra ™ Esthetic Resin Cement (Dentsply Caulk, USA), Group C: RelyX ARC Adhesive Resin (3M ESPE), Group D: RelyX Unicem Aplicap (3M ESPE). Each root was sliced into 2 discs representing the coronal and middle portions of the root canal giving rise to 20 specimens per group. Bond strength was determined using push-out tests and data was analyzed using SPSS version 14.0. The mean bond strength of Group A to Aestheti-Plus™ post was 7.71 MPa (±2.51) and Group B was 5.69 MPa (±3.23). Group C exhibited the lowest mean bond strength, 4.29 MPa (±3.53) while the highest bond strength was obtained from Group D, 7.98 MPa (±2.61). One way ANOVA showed significant interaction between all groups (p=.OOI). Post-hoc Bonferroni test reve;iled that bond strength of Group C was significantly lower compared to Group A (p=.008) and D (p=.004). In conclusion, the mean bond strength of Aestheti- Plus™ post to root canal dentine was highest when cemented with RelyX Unicem resin cement followed by Elite 100® zinc phosphate cement, Calibra and RelyX ARC resin cements. However, the bond strengths of Cali bra and RelyX Unicem resin cements were not significantly different from Elite 100® zinc phosphate cement.
  3. Radzi, Z., Abu Kasim, N.H., Yahya, N.A., Abu Osman, N.A., Kassim, N.L.
    Ann Dent, 2008;15(1):33-39.
    MyJurnal
    The purpose of this study was to investigate the light intensity of selected light curing units with varying distance and angulation of the light curing tip and lightmeter. Materials and method: Four types of light units; Spectrum 800 (Dentsply), Coltulux 3 (Coltene), Elipar FreeLight 2 (3M Espe) and Starlight Pro (Mectron) were evaluated for light intensity at various distances between the light curing tip and the radiometer Cure Rite Denstply (0,1,3,5,10 and 15 mm). The light curing units were tested at right angles to the aperture of the light meter and at the angles of 45°, 60° to it at a standardized 5 mm distance. Results: The highest light intensity was obtained when the tip of light curing unit was in contact with the lightmeter aperture. The light intensity decreased significantly when the light tip was placed 5mm, 10mm and 15mm away from the lightmeter aperture. However, no significant differences (p> .05) were detected between Omm, Imm and 3mm. There was a decrease in light intensity when light~·tip was angulated at 45° and 60° except for Coltolux 3. Conclusions: The intensity of the curing light was affected by the distance between the light curing tip and the lightmeter. However, the decrease in light intensity of the light curing unit was found not to obey the inverse square law for the distances 0 to 15 mm. The study found that there was no significant difference between 45° and 60° angulation between the light curing tip and the lightmeter. However, the decrease in light intensity was significant when compared to the light tip placed perpendicular (90°) to the aperture of the light meter.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links