Affiliations 

  • 1 Universiti Teknologi MARA
Scientific Research Journal, 2006;3(1):53-68.
MyJurnal

Abstract

A conventional plate girder involves the use of transverse intermediate
stiffeners, especially in a slender web to avoid catastrophic failure associated
with shear buckling of the web. In this study, a profiled web was used to
replace the transversely stiffened web. The process involves introducing coldformed
ribs into a flat steel sheet to form alternative stiffeners. This study
therefore seeks to establish comparative performance of conventionally
stiffened plate girders and profiled web girders of a specially formed rib
arrangement with single and also double webs. Nine numbers of specimens
were tested to failure under a three-point-bending system. Failure of all the
profiled web girders, with either a single or double webs, is characterized by
a shorter yield plateau and a steeper descending branch, a failure mode that
is commonly referred to as ‘brittle’. The results of the tests on girders with
profiled steel sheets, PSS(s) have shown that profiling is extremely effective in
increasing the shear buckling load because it moves the sheet material out of
the plane of the web, thereby increasing the rigidity 1.08 to 2.0 times higher
than the equivalent conventional flat web plate girders. The experimental
results also showed that post-buckling capacities are reduced by 30 % to
50 % of their ultimate shear capacities.